Khotimatul Fauziah

Dr. Khotimatul Fauziah

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2021
Verified
Conference Paper
Closed access
DRDionysius A. Renata
Dionysius A. Renata
KFKhotimatul Fauziah
Khotimatul Fauziah
PAPrasetyo Aji
Prasetyo Aji
ALAdisa Larasati
Adisa Larasati
HHHafsah Halidah
Hafsah Halidah
RIRiza
Riza
Several electric vehicle charging station infrastructures (EVCS) have been built in Indonesia, both private and public. A centralized management system is required to manage several charging stations. The central system uses collected historical charging transaction data to analyze patterns of EVCS energy consumption. A supervised machine learning model is applied to forecast the charging station (CS) energy consumption for the next day based on the daily transaction of the previous days. Weather condition data are also applied as additional parameters to determine their effect on charging energy consumption. Four machine learning algorithms have been evaluated, including Random Forest (RF), Support Vector Regression (SVR), XGBoost, and Multilayer Perceptron (MLP). MLP obtained the best accuracy value with an R 2 score of 0.85 and RMSE of 115.17 for the model without the weather variables. Meanwhile, SVR outperforms all models using a dataset with weather variables. Overall, MLP and SVR can perform well on both types of datasets. This result is expected to be used as a reference method for energy consumption prediction in the electric vehicle charging infrastructure in Indonesia.

1 July 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
KFKhotimatul Fauziah
Khotimatul Fauziah
YSY. Suzuki
Y. Suzuki
TNT. Nogita
T. Nogita
YKY. Kamakura
Y. Kamakura
TWT. Watanabe
T. Watanabe
HIHiroya Ikeda
Hiroya Ikeda
For highly efficient thermoelectric devices with Si nanostructures, we have fabricated and characterized micro/nanometer-scaled Si wires preserving the phonon-drag effect in order to observe the impact of phonon-boundary scattering on the phonon-drag factor in its Seebeck coefficient. The observed phonon-drag factor in the Seebeck coefficient decreases with a decrease in the wire width, which is considered due to an increase in the boundary scattering of phonons. Since the boundary scattering is characterized by the specularity parameter, we measured the surface roughness of the wire and evaluated the specularity. It was found that the top surface of the Si wire has higher specularity compared with the sidewall of the wire in the range of phonon wavelength contributing to the phonon drag. This result qualitatively explains the fact that the phonon drag in the Seebeck coefficient is hardly affected by the wire thickness with a nanometer order, whereas the wire width influences it significantly even on a micrometer scale. Moreover, it is demonstrated that the phonon-drag effect in the Seebeck coefficient of Si nanostructures can be preserved while their thermal conductivity is lowered.

1 October 2017
Verified
Conference Paper
Closed access
YAYuli Astriani
Yuli Astriani
KFKhotimatul Fauziah
Khotimatul Fauziah
HHHamzah Hilal
Hamzah Hilal
RIRiza
Riza
BPBudi Prasetyo
Budi Prasetyo
The Sumba smart microgrid project was built in 2012 as a research means to demonstrate PV power plant integration into utility grid that implemented modern control and information technology to reduce effects of intermittency PV output. It consists of PV, battery, diesel generator, and SCADA subsystem. Since battery subsystem had a problem in its PCS system then some changes in compensation algorithm are needed to maintain grid reliability. In this paper, PV-diesel load sharing algorithm was added to the diesel generators operation control to compensate fluctuation of PV output, with its main purpose is to deliver constant power to the grid. Load sharing control system receive the data of PV output and adjust the diesel power output by controlling governor and AVR (Automatic Voltage Regulator). In this research, the total power output from the system is limited to 150kW. For example, if PV produced 100kW, then diesel generator operation controller drove the diesel generators to produce 50kW. Digital power meters were installed on PV and generator to measure active power, voltage, frequency, and power factor. These data were used as input parameters for load sharing control. Settings up and down the diesel generator power output is done automatically by the PLC (programmable logic controller) module using PID (proportional integral derivative) algorithm. Testing is done by on or off the inverter to simulate the rise and fall of power from PV output. Testing results show that diesel can compensate PV power reduction relatively fast. The proposed method could be used to leveling PV output power fluctuation and reduce the frequency deviations and maintain resilience on the microgrid.

5 November 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
NHNurry Widya Hesty
Nurry Widya Hesty
KFKhotimatul Fauziah
Khotimatul Fauziah
AMAminuddin
Aminuddin
TZToha Zaky
Toha Zaky
SFSilvy Rahmah Fithri
Silvy Rahmah Fithri
IFIfanda
Ifanda

1 September 2023 in Evergreen
Verified
Journal Article
Closed access
ENEka Nurdiana
Eka Nurdiana
VNVetri Nurliyanti
Vetri Nurliyanti
DRDhea Amelia Rianjani
Dhea Amelia Rianjani
KAKholid Akhmad
Kholid Akhmad
AKAsih Kurniasari
Asih Kurniasari
SSSuhraeni Syafei
Suhraeni Syafei

5 October 2021
Verified
Conference Paper
Closed access
KFKhotimatul Fauziah
Khotimatul Fauziah
YAYuli Astriani
Yuli Astriani
DRDionysius A. Renata
Dionysius A. Renata
ASAfrias Sarotama
Afrias Sarotama
ASAgus Suhendra
Agus Suhendra
RIRiza
Riza
Electric vehicle supply equipment (EVSE) is a battery charging system for electric vehicles (EVs). EVSE must be designed to refer to the applicable standards to ensure security and interoperability with various types of EV. This paper explains the design of EVSE for mode 3 AC charging station (CS) based on International standard IEC 61851-1. The design follows the safety requirements on IEC 61851-1, such as overvoltage, overcurrent, and residual current devices to protect persons against electric shocks. Moreover, the charge controller manages the functionality of the devices and their communication so that energy transfers safely. The EVSE is equipped with a human-machine interface (HMI) using Raspberry Pi as the central processor to communicate between CS and EV users. The open charge point protocol (OCPP) is installed for communication between CS and the back-end system; thus, CS can be monitored and managed from the central system. The design is implemented for a 22 kW 3-phase AC EVSE and its testing result demonstrated a successful charging process to the commercial EV, Mitsubishi i-MiEV.