Endogenous volatile organic compounds (VOCs) in human exhaled gases can reflect human health status and be used for clinical diagnosis and health monitoring. Acetone is the sign VOC gases of diabetes mellitus. In order to find a potential material for the detection of acetone in the application of the clinical diagnosis of diabetes mellitus. The adsorption properties, including adsorption energy, adsorption distance, charge transfer, density of states, electron localization function and electrons density difference, of acetone on BN monolayer doped with Ni were comprehensively investigated based on density functional theory. The results show that there could be chemisorption between acetone and Ni-BN monolayer and Ni-BN monolayer is probably suitable gas sensitive material for the detection of acetone in the application of diabetes mellitus monitoring and clinical diagnosis.
The wire tightener is a critical tool in the construction and maintenance of power lines. Failure to detect tension overload in a timely manner may lead to plastic deformation or even breakage of the tool, potentially causing serious safety accidents. To address this issue, a force monitoring sensor was developed to track the real-time load on wire tighteners. In terms of hardware design, a foil strain gauge was integrated with an ultra-low-power mixed-signal microcontroller based on the mechanical characteristics of the wire tightener, enabling accurate acquisition and processing of load data. Low-power LoRa technology was employed for wireless data transmission, and an adaptive sleep–wake strategy was implemented to optimize power efficiency during data collection. The sensor’s material, geometry, and structure were tailored to the tool’s composition and working environment. Experimental results showed that the average relative error between the sensor readings and the reference values was less than 0.5%. The sensor has been successfully deployed in practical engineering applications, consuming approximately 4500 mWh over an 8 h continuous monitoring period.
The gas sensitivity of platinum doped TiO2 (101) to two kinds on polyvinyl chloride decomposition production, CO and HCl, were explored based on density functional theory. The binding energy, adsorption distance, charge transfer, and density of states distribution were simulated and discussed. The results suggest that the O oriented mode is probably the best mode for the CO gas molecules adsorption on the Pt-TiO2 and H oriented mode for the HCl adsorption system. HCl and CO molecules obtain electrons from Pt doped TiO2 surface. At room temperature, the recovery time of CO and HCl is 1.9743 × 10-10, 1.2094 × 10-10 respectively. HCl is easier to dissociate from Pt doped TiO2 surface with a little lower energy barrier compared to CO. This work provides theoretical adsorption information of Pt-TiO2 as gas sensor material for HCl and CO detection in the application of online condition monitoring and defect diagnosis in the power cables.