This study aimed to compare the surface roughness, hardness, and flexure strength of interim indirect resin restorations fabricated with CAD-CAM (CC), 3D printing (3D), and conventional techniques (CV). Twenty disk (3 mm × Ø10 mm) and ten bar specimens (25 × 2 × 2 mm) were fabricated for the CC, 3D, and CV groups, to be used for surface roughness, micro-hardness, and flexural strength testing using standardized protocol. Three indentations for Vickers micro-hardness (VHN) were performed on each disk and an average was identified for each specimen. Surface micro-roughness (Ra) was calculated in micrometers (μm) using a 3D optical non-contact surface microscope. A three-point bending test with a universal testing machine was utilized for assessing flexural strength. The load was applied at a crosshead speed of 3 mm/min over a distance of 25 mm until fracture. Means and standard deviations were compared using ANOVA and post hoc Tukey–Kramer tests, and a p-value of ≤0.05 was considered statistically significant. Ra was significantly different among the study groups (p < 0.05). Surface roughness among the CC and CV groups was statistically comparable (p > 0.05). However, 3D showed significantly higher Ra compared to CC and CV samples (p < 0.05). Micro-hardness was significantly higher in 3D samples (p < 0.05) compared to CC and CV specimens. In addition, CC and CV showed comparable micro-hardness (p > 0.05). A significant difference in flexural strength was observed among the study groups (p < 0.05). CC and 3D showed comparable strength outcomes (p > 0.05), although CV specimens showed significantly lower (p < 0.05) strength compared to CC and 3D samples. The 3D-printed provisional restorative resins showed flexural strength and micro-hardness comparable to CAD-CAM fabricated specimens, and surface micro-roughness for printed specimens was considerably higher compared to CAD-CAM and conventional fabrication techniques.
The present study aimed to formulate an experimental adhesive (EA) and reinforce it with 5 wt.% titanium dioxide (TiO2) or zirconium oxide (ZrO2) to yield 5% TiO2 and 5% ZrO2 adhesives, respectively, and then analyze the impact of this reinforcement on various mechanical properties of the adhesives. The EA contained a blend of monomers such as bisphenol A glycol dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA), 2-hydroxyethyl methacrylate (HEMA), and ethyl 4-dimethylamino benzoate and camphorquinone. The EA included ethyl 4-dimethylamino benzoate and camphorquinone photo-initiators, and diphenyliodonium hexafluorophosphate (DPIHP) was also included to act as an electron initiator. The TiO2 and ZrO2 nanoparticles were incorporated into the EA post-synthesis. To characterize the filler nanoparticles, scanning electron microscopy (SEM) and line-energy dispersive X-ray (EDX) spectroscopy were performed. The adhesives were characterized by analyzing their rheological properties, shear-bond strength (SBS), and interfacial failure types. Further, the resin–dentin interface was also analyzed via SEM. The TiO2 nanoparticles were spherically shaped on the SEM micrographs, while the ZrO2 nanoparticles were seen as non-uniformly shaped agglomerates. The EDX mapping demonstrated the presence of Ti and oxygen for TiO2 and Zr and oxygen for the ZrO2 nanoparticles. Both 5% TiO2 and 5% ZrO2 adhesives revealed decreased viscosity as compared with the EA. The 5% TiO2 adhesive demonstrated higher SBS values for both non-thermocycled (NTC) and thermocycled samples (NTC: 25.35 ± 1.53, TC: 23.89 ± 1.95 MPa), followed by the 5% ZrO2 adhesive group (NTC: 23.10 ± 2.22, TC: 20.72 ± 1.32 MPa). The bulk of the failures (>70%) were of adhesive type in all groups. The SEM analysis of the resin–dentin interface revealed the development of a hybrid layer and resin tags (of variable depth) for the EA and 5% TiO2 groups. However, for the 5% ZrO2 group, the hybrid layer and resin tag establishment appeared compromised. Reinforcement of the EA with TiO2 or ZrO2 caused an increase in the adhesive’s SBS (with the 5% TiO2 group demonstrating the highest values) in comparison with the EA (without nanoparticles). However, both nanoparticle-containing adhesives revealed decreased viscosity compared with the EA (without nanoparticles). Further studies investigating the impact of diverse filler concentrations on the properties of adhesives are suggested.
Our study assessed the influence of integrating 5% and 10% tricalcium phosphate (β-TCP-Ca3(PO4)2.) nanoparticles into a dental adhesive on the adhesive’s bonding. To evaluate the filler nanoparticles, scanning electron microscopy (SEM), Energy Dispersive X-Ray (EDX) spectroscopy, Fourier-transform infrared (FTIR) spectroscopy, and micro-Raman spectroscopy techniques were used. Shear Bond strength (SBS) testing, degree of conversion (DC) analysis, investigation of the adhesive–dentin interface, and biofilm experiments were conducted. The SEM micrographs revealed non-uniform agglomerates, while the EDX demonstrated the existence of oxygen ‘O’ (24.2%), phosphorus ‘P’ (17.4%) and calcium ‘Ca’ (60.1%) in the β-TCP nanoparticles. The FTIR and micro-Raman spectra indicated characteristic bands for β-TCP containing materials. The 10 wt.% β-TCP adhesive presented the highest SBS values (NTC-10 wt.% β-TCP: 33.55 ± 3.73 MPa, TC-10 wt.% β-TCP: 30.50 ± 3.25 MPa), followed by the 5 wt.% β-TCP adhesive (NTC-5 wt.% β-TCP: 32.37 ± 3.10 MPa, TC-5 wt.% β-TCP: 27.75 ± 3.15 MPa). Most of the detected failures after bond strength testing were adhesive in nature. The β-TCP adhesives demonstrated suitable dentin interaction by forming a hybrid layer (with few or no gaps) and resin tags. The β-TCP adhesives (10 wt.%) revealed lower DC values compared to control. The incorporation of 5 and 10 wt.% concentrations of β-TCP particles resulted in an increase in SBS values. A linear decline in DC values was witnessed when the nanoparticle concentration was increased. Further research focusing on exploring the influence of higher filler concentrations on adhesive’s properties is recommended.
This study aimed to analyze the enamel remineralization efficacy of a novel fluoridated bioactive glass (F-BG) toothpaste compared to a standard fluoride toothpaste. Seventy-two enamel blocks (N = 72) were divided into groups of twenty-four blocks according to the toothpaste exposure—group 1: brushed with distilled water, group 2: brushed with fluoride toothpaste (ColgateTM), and group 3: brushed with F-BG toothpaste (BioMinFTM). Pre-brushing, enamel blocks were demineralized using 6 wt.% citric acid (pH = 2.4). Tooth brushing was performed using a mixture of respective toothpaste and artificial saliva (AS), and each enamel block received 5000 linear strokes. The samples were assessed for surface micro-hardness (to estimate Vickers hardness number, VHN), surface roughness (Ra), and volume loss/gain using micro-computed tomography (micro-CT). The highest increase in the VHN was noticed for group 3 (117.81) followed by group 2 (61.13), and all the intragroup comparisons were statistically significant (p < 0.05). Demineralization increased the Ra values, and a decrease was observed post-remineralization for all the groups. The maximum Ra decrease was observed for group 3 (−223.2 nm) followed by group 2 (−55.6 nm), and all the intragroup comparisons were again statistically significant (p < 0.05). Micro-CT investigation revealed that the enamel volume decreased after demineralization and increased after remineralization among all groups. The F-BG toothpaste showed greater enamel surface micro-hardness (increased VHN), smoother surface (low roughness), and better volume restoration (remineralization) in comparison to the fluoride toothpaste.
The aim of the present study was to evaluate the effect of brushing with two whitening dentifrices (Colgate Optic White (COW) and Colgate Optic White Charcoal (COC)) on surface gloss, micro-roughness, and micro-hardness of nanostructured hybrid conventional (Z350) and bulk-fill (Tetric N Ceram bulk-fill) polymer composite. In total, 96 disk samples using two nano-hybrid composite polymers (Z350 and Tetric N Ceram Bulk-fill) were prepared. All specimens were exposed to two different dentifrices (COW and COC), resulting in four main subgroups in the study. Specimens were assessed for surface gloss, micro-roughness (Ra), and micro-hardness using standardized methodology. Means and standard deviations of properties compared using paired t-test, one-way and two-way ANOVA, and post hoc test. The presence of dentifrices did not show any significant difference in micro-hardness values of Z350 (p > 0.05), whereas micro-hardness of bulk-fill composite significantly reduced on dentifrices exposure (p ≤ 0.05). Bulk-fill polymer composite showed significant reduction in gloss after dentifrice exposure (p < 0.05), however, Z350 showed no significant loss of gloss due to dentifrices (p > 0.05). A significant increase in Ra was observed for both resin materials after exposure to dentifrices (COC and COW). Conventional resin composite (Z350) showed comparable surface hardness and gloss before and after dentifrice exposure, however, micro-roughness increased significantly due to dentifrice exposure. Bulk-fill resin (Tetric N Ceram) showed significant loss of micro-hardness and gloss and increase in micro-roughness on dentifrice exposure. Conventional nano-hybrid composite polymer showed better durability in resisting loss of surface properties compared to bulk-fill resin polymer in the present experiment.
The aim of the study was to compare microleakage and fracture loads of all ceramic crowns luted with conventional polymer resins and polymeric bioactive cements and to assess the color stability of polymeric bioactive cements. Seventy-five extracted premolar teeth were tested for fracture loads and microleakage in all-ceramic crowns cemented with two types of polymeric bioactive cements and resin cements. In addition, the degree of color change for each cement with coffee was assessed. Thirty maxillary premolar teeth for fracture loads and thirty mandibular premolar teeth for microleakage were prepared; standardized teeth preparations were performed by a single experienced operator. All prepared specimens were randomly distributed to three groups (n = 20) based on the type of cement, Group 1: resin cement (Multilink N); Group 2: polymeric bioactive cement (ACTIVA); Group 3: polymeric bioactive cement (Ceramir). The cementation procedures for all cements (Multilink, ACTIVA, and Ceramir) were performed according to the manufacturers’ instructions. All specimens were aged using thermocycling for 30,000 cycles (5–55 °C, dwell time 30 s). These specimens were tested using the universal testing machine for fracture strength and with a micro-CT for microleakage. For the color stability evaluation, the cement specimens were immersed in coffee and evaluated with a spectrometer. Results: The highest and lowest means for fracture loads were observed in resin cements (49.5 ± 8.85) and Ceramir (39.8 ± 9.16), respectively. Ceramir (2.563 ± 0.71) showed the highest microleakage compared to resin (0.70 ± 0.75) and ACTIVA (0.61 ± 0.56). ACTIVA cements showed comparable fracture loads, microleakage, and stain resistance compared to resin cements.