Safety and accuracy are essential for path planning in a surgical navigation system. In this paper, an improved path planning algorithm is proposed to increase the autonomous level of spine surgery robots for higher safety and accuracy. Firstly, dynamic gravitational constant and piecewise repulsion function are adopted to improve the traditional Artificial Potential Field algorithm to solve common issues of path planning, including local minimum, unable to reach target near obstacles. To better control the pose of the end-effector in operation space, the positions of the two endpoints of the end-effector are further constrained. Secondly, an improved Primal-Dual Neural Network with multiple constraints is proposed to minimize the joint angular velocity norm. The multiple constraints are formulated according to the planned path, the obstacle avoidance of the robot and the joint limits. Moreover, a real-time planned velocity scheme based on the position error of each step is applied to prevent the accumulation of position errors. The simulation results of pedicle screw implantation demonstrate that the robot can find the collision-free trajectory and arrive at the target position in various complicated situations. The position error is around [[EQUATION]] m. Finally, two experiments are conducted to verify the proposed algorithm is effective in practice.
In surgical navigation-assisted pedicle screw fixation, cross-source pre- and intra-operative point clouds registration faces challenges like significant initial pose differences and low overlapping ratio. Classical algorithms based on feature descriptor have high computational complexity and are less robust to noise, leading to a decrease in accuracy and navigation performance. To address these problems, this paper proposes a coarse-to-fine registration framework. In the coarse registration stage, a Point Matching algorithm based on Curvature Feature Learning (CFL-PM) is proposed. Through CFL-PM and Farthest Point Sampling (FPS), the coarse registration of overlapping regions between the two point clouds is achieved. In the fine registration stage, the Iterative Closest Point (ICP) is used for further optimization. The proposed method effectively addresses the challenges of noise, initial pose and low overlapping ratio. In noise-free point cloud registration experiments, the average rotation and translation errors reached 0.34° and 0.27 mm. Under noisy conditions, the average rotation error of the coarse registration is 7.28°, and the average translation error is 9.08 mm. Experiments on pre- and intra-operative point cloud datasets demonstrate the proposed algorithm outperforms the compared algorithms in registration accuracy, speed, and robustness. Therefore, the proposed method can achieve the precise alignment of the surgical navigation-assisted pedicle screw fixation.