Nan Zhang

Dr. Nan Zhang


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ZZZhentian Zhou
Zhentian Zhou
BWBo Wu
Bo Wu
JDJuan Duan
Juan Duan
XZXu Zhang
Xu Zhang
NZNan Zhang
Nan Zhang
ZLZhiyuan Liang
Zhiyuan Liang
An image-guided surgical navigation system breaks through the limits of the traditional surgical operation and extends the doctors’ limited vision scope.1,2 Tracking and positioning are the key techniques of an image-guided surgical navigation system. The accuracy of the tracking method directly determines the accuracy of the image-guided surgical navigation system. An optical tracking system is designed, using light-emitting markers, combined with self-developed image processing methods and an easy-to-implement three-dimensional (3-D) space tracking algorithm, which achieves the high tracking accuracy of surgical instruments.

26 October 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
LHLinjia Hao
Linjia Hao
DLDongdong Liu
Dongdong Liu
SDShuxian Du
Shuxian Du
YWYu Wang
Yu Wang
BWBo Wu
Bo Wu
NZNan Zhang
Nan Zhang

20 May 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
MZMengshi Zhang
Mengshi Zhang
BWBo Wu
Bo Wu
CYCan Ye
Can Ye
YWYu Wang
Yu Wang
JDJuan Duan
Juan Duan
NZNan Zhang
Nan Zhang
Optical surgical navigation system has been a hot research topic because of its high accuracy. This paper focuses on identifying and tracking multiple surgical instruments to meet the requirements of applying multiple surgical instruments in clinical medicine. The methods of instrument identification based on the marker's geometrical arrangement and instrument tracking based on markers’ motion vector were applied in the proposed algorithm. The experiments of multiple instruments’ identification and tracking, the instruments’ stability, the space distance and rotation of a pair of instruments at the same tracking time were performed to verify the proposed algorithm. The stereoscopic camera is applied to capture images, and two 850 nm filters are added in front of the binocular camera. The tracking experiment shows that ten instruments can be fully and accurately identified, and then all of them can be quickly and accurately tracked at the same time. A pair of instruments is simultaneously measured in the stability test, such as the typical surgical instrument (TSI) and the miniature surgical instrument (MSI). The ranges of standard deviations (SD) of the stability test for the TSI in the X-, Y-, and Z- axes are from 0.016 mm to 0.127 mm, from 0.011 mm to 0.090 mm, and from 0.124 mm to 0.901 mm, respectively. And the ranges of SDs for the MSI’s stability test are from 0.011 mm to 0.133 mm in the X-axis, from 0.010 mm to 0.106 mm in the Y-axis, and from 0.093 mm to 0.932 mm in the Z-axis. The sub-millimeter SDs show that the proposed algorithm has a high stability. Moreover, the space distance test and the rotation test were performed for simultaneously tracking TSI and MSI. All experimental results indicate the proposed algorithm is able to meet the clinical accuracy requirements.

13 February 2025 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Open access
XJXingqiang Jian
Xingqiang Jian
YSYibin Song
Yibin Song
DLDongdong Liu
Dongdong Liu
YWYu Wang
Yu Wang
XGXueqian Guo
Xueqian Guo
NZNan Zhang
Nan Zhang
Current orthopedic surgical robots are widely used in pedicle screw implantation tasks due to their precise positioning capabilities. However, the surgical operation processes, including surgical pose alignment and the drilling of the pedicle screw placement path, remain heavily dependent on the surgeon, indicating that the level of automation still needs improvement. This paper aims to enhance automation in pedicle screw implantation tasks through a combination of imitation learning and constraint optimization, thereby ensuring both reliability and safety. Firstly, a high-level motion planning method, leveraging Cartesian space dynamic movement primitives (CDMP) based imitation learning and an image-guided optical navigation system (I-GONS), is proposed to generate the task space path of the rough surgical pose alignment and fine surgical pose alignment, as well as for the drilling of pedicle screw placement path. Secondly, end-effector velocity control based on position and orientation errors (POE-EVC) is employed to follow the high-level planned path. This is achieved by constructing a quadratic programming (QP) problem with the robot kinematic constraints and manipulability optimization. Concurrently, the low-level motion control is addressed online using a modified linear variational inequality based primal dual neural network (mLVI-PDNN). Experimental results demonstrate the distance errors in multiple pedicle screw implantation tasks are $0.738\pm 0.080$ mm and $0.154\pm 0.031$ mm at the entry and target points, respectively. And the angular errors between the actual drilling path compared to the planned screw placement path are $0.005\pm 0.002$ degrees. These results show that the proposed methodology offers a reliable and innovative solution for the higher level of automation in the pedicle screw implantation procedure.Note to Practitioners—The study is driven by the need for higher levels of automation in orthopedic surgery for pedicle screw implantation tasks. Orthopedic surgical robots are usually deployed in complicated surgeries due to their excellent positioning capabilities. However, they primarily rely on basic kinematic constraints and cooperative control modes, thus lacking a reliable mechanism for active surgical pose alignment and screw path drilling, especially in complex surgical scenarios that involve only optical tracking systems (OTS) without additional vision sensors. For example, current popular OTS systems have a limited field of view and cannot fully acquire information about the surgical scene, which impacts collision-free path planning. To address these issues, a novel methodology combining CDMP based imitation learning with QP based motion control for the task of pedicle screw implantation is introduced. Incorporating surgeons’ prior knowledge of the surgical environment and their participation in the robot’s motion planning using the CDMP model enhances the robot’s autonomy and increases reliability in surgeries, without requiring additional vision sensors. This approach allows for accurate reconstruction of multiple surgical targets of automatic surgical pose alignment and pedicle screw drilling, while respecting manipulability optimization and the robot’s kinematic constraints, rather than merely imitating and ignoring the robot’s kinematic structure. This methodology is also applicable to various clinical surgical operations and industrial applications.

15 February 2020 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
YWYu Wang
Yu Wang
BWBo Wu
Bo Wu
NZNan Zhang
Nan Zhang
JLJiabao Liu
Jiabao Liu
FRFei Ren
Fei Ren
LZLiqin Zhao
Liqin Zhao
BACKGROUND AND OBJECTIVE: Since CAD (Computer Aided Diagnosis) system can make it easier and more efficient to interpret CT (Computer Tomography) images, it has gained much attention and developed rapidly in recent years. This article reviews recent

24 August 2012 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
BWBo Wu
Bo Wu
NZNan Zhang
Nan Zhang
SMSiwei Ma
Siwei Ma
DZDebin Zhao
Debin Zhao
WGWen Gao
Wen Gao