LI Yunfei

Dr. LI Yunfei

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
SYSong yuze Yuze
Song yuze Yuze
LYLI Yunfei
LI Yunfei
CLChao Li
Chao Li
FLFeng Luo
Feng Luo
FCFuhong Cai
Fuhong Cai
Spectroscopic technology offers the advantage of rapid online monitoring and has attracted significant attention in molecular detection. However, the complex optical spectroscopic structure results in a relatively complex structure for spectral detection systems, limiting their widespread application. In water spectral detection, in addition to ensuring the stability of the optical system, waterproofing is also crucial. Therefore, developing miniaturized spectral detection modules in water spectral detection can improve system stability and reduce the complexity of developing and maintaining underwater hardware. This work develops a compact multispectral detection system centered on a miniature multispectral sensor. The system, controlled by a microcontroller, detects eight spectral channels within the 400–700 nm range and transmits data via the I2C bus. The sensitivity and stability of the detection are sufficient for water reflectance spectral detection. Based on the reflectance spectrum obtained by the above module, this work develops a regression algorithm to estimate the chlorophyll concentration in water. By comparing with standard chlorophyll concentration detection instruments, the results demonstrate the effectiveness of the proposed system in accurately estimating chlorophyll concentration.

22 July 2026 in Applied Spectroscopy
Verified
Journal Article
Closed access
BCBo Cheng
Bo Cheng
ZCZhoushuai Chen
Zhoushuai Chen
CLCunguang Lou
Cunguang Lou
LYLI Yunfei
LI Yunfei
RLRuikai Li
Ruikai Li
The combination of laser-induced breakdown spectroscopy (LIBS) and machine learning provides a rapid approach for coal ash quantification. However, in practical coal preparation plants, calibration samples are often limited, and ash contents are usually confined to a narrow range, making reliable quantitative modeling difficult. To address this issue, we propose a structured spectral in-context learning framework for small-sample coal ash quantification. Unlike conventional methods that rely on task-specific iterative parameter optimization, the proposed framework performs downstream inference by conditioning on a limited set of calibration samples using a pre-trained tabular foundation model. To adapt continuous high-dimensional LIBS spectra to this framework, segmented statistical descriptors and multi-scale Haar-like features were constructed to capture subtle local spectral variations associated with narrow ash-content changes. The experimental results show that the proposed SS-ICL framework achieves robust predictive performance under restricted conditions, with an R 2 of 0.8880 and an RMSE of 0.1953 in a narrow-range washed-coal scenario. These results demonstrate that the proposed framework provides a practical and robust strategy for on-site LIBS-based coal quality analysis in restricted industrial environments.

18 September 2026 in Photonics
Verified
Journal Article
Open access
PDF file
黎黎黎冠成 黎
黎冠成 黎
汶李汶轩 李
汶轩 李
LYLI Yunfei
LI Yunfei
FCFuhong Cai
Fuhong Cai
The optical response of skin tissue in the near-ultraviolet to short-wave infrared band (350–2350 nm) contains rich physiological information such as hemodynamics, hydration status, and lipid metabolism. However, due to limitations in detector technology, conventional spectroscopic systems often use a single type of detector: silicon-based CCD (effective wavelength ≤ 1100 nm) captures visible blood features but cannot cover the long-wave vibration bands of water/lipids, while InGaAs (effective wavelength ≥ 900 nm) is sensitive to long-wave water/lipid absorption but misses the strong blood absorption in the visible region. This spectral detector segmentation leads to a separation of blood features from tissue background signals. In addition, traditional single source-probe distance measurement only probes one depth and cannot observe tissue information at different depths by varying the source-probe distance. This study employs a dual-spectrometer splicing architecture to achieve seamless continuous spectral measurement across 350–2350 nm by amplitude registration and normalization in the overlapping region. Using the thumb, palm, and arm as representative sites, we systematically analyzed spectral differences under varying vascular densities and fat backgrounds and successfully extracted absorption features of major chromophores including blood, water, and lipids. The results showed that the dual-spectrometer splicing method achieved smooth transitions in the overlapping region across different sites, validating its reliability. Spectral differences across sites were mainly characterized by hemoglobin absorption features in the visible region and water/lipid vibrational absorption features in the short-wave infrared region. These findings demonstrate the feasibility of dual-spectrometer splicing for broadband tissue spectral acquisition, enabling simultaneous capture of multi-component signals, and providing a new technical approach for non-invasive tissue composition analysis.