汶轩 李

Mr. 汶轩 李


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
汶李汶轩 李
汶轩 李
CWChirui Wan
Chirui Wan
PXPeng Xu
Peng Xu
Xiaofeng XieXiaofeng Xie
Xiaofeng Xie
FCFuhong Cai
Fuhong Cai
FZFeifan Zhou
Feifan Zhou
The photothermal effect is an important part of biological tissue optics. The reasonable use of temperature changes caused by the photothermal effect is of great value for the treatment of lesions. However, it is not easy to measure changes in light and heat temperatures in tissues experimentally. This paper combines Monte Carlo simulation and finite-element numerical calculation based on the Pennes biological tissue heat transfer equation to simulate light transmission and distributions of light and heat in biological tissues, including single-layer uniform biological tissue simulations and a classic three-layer skin optical model. Through the simulation of single-layer uniform biological tissue, the overall trend and range of biological tissue temperature change under different parameters are obtained in this work. Third, in the classic three-layer skin optical model simulation, this work combines a data-fitting method to derive a formula relating internal temperature and tissue depth to the absorption coefficient. Compared with the simulation standard results, the error of the above fitting formula is within 1.2%, and it can be applied in the field of photothermal therapy in the future to help medical workers understand the range of temperature changes in biological tissues.

2 May 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
JWJun Wei
Jun Wei
LMLansixu Ma
Lansixu Ma
汶李汶轩 李
汶轩 李
PXPeng Xu
Peng Xu
艺王艺臻 王
艺臻 王
FCFuhong Cai
Fuhong Cai
Phototherapy is a physical treatment modality that utilizes natural or artificial light sources and harnesses radiant energy to treat diseases. Dynamic monitoring of the actual light dose received by tissues is crucial to the success of phototherapy. However, most current phototherapy devices feature bulky and complex hardware and depend on fixed parameters or surface measurements for dose estimation, failing to provide precise, real-time monitoring of light dose distribution that is tailored to individual users, specific treatment sessions, and different body regions. Furthermore, most of these devices are incapable of generating tunable and stable LED light. This study presents a preliminary diffusion equation-based proof-of-concept for a wearable, integrated dual-mode sensing system for real-time dynamic monitoring of tissue light dose and temperature change. The system, controlled by a single-chip microcontroller, rapidly extracts key tissue optical parameters via a custom multi-wavelength LED optical probe and provides real-time feedback on light dose distribution through a dynamic tissue optical simulation model. To expand the monitoring dimensions, the system innovatively integrates a thermal sensor. This sensor enables synchronous monitoring of the temperature field in the treatment area, thereby allowing for an estimation of the combined photothermal effect. The system features a compact design, user-friendly operation, fast and stable communication, and repeatable and reliable detection. With promising clinical application prospects, it holds the potential to evolve into a portable, home-use, safe, effective, wearable, and cost-effective phototherapy device.

18 September 2026 in Photonics
Verified
Journal Article
Open access
PDF file
黎黎黎冠成 黎
黎冠成 黎
汶李汶轩 李
汶轩 李
LYLI Yunfei
LI Yunfei
FCFuhong Cai
Fuhong Cai
The optical response of skin tissue in the near-ultraviolet to short-wave infrared band (350–2350 nm) contains rich physiological information such as hemodynamics, hydration status, and lipid metabolism. However, due to limitations in detector technology, conventional spectroscopic systems often use a single type of detector: silicon-based CCD (effective wavelength ≤ 1100 nm) captures visible blood features but cannot cover the long-wave vibration bands of water/lipids, while InGaAs (effective wavelength ≥ 900 nm) is sensitive to long-wave water/lipid absorption but misses the strong blood absorption in the visible region. This spectral detector segmentation leads to a separation of blood features from tissue background signals. In addition, traditional single source-probe distance measurement only probes one depth and cannot observe tissue information at different depths by varying the source-probe distance. This study employs a dual-spectrometer splicing architecture to achieve seamless continuous spectral measurement across 350–2350 nm by amplitude registration and normalization in the overlapping region. Using the thumb, palm, and arm as representative sites, we systematically analyzed spectral differences under varying vascular densities and fat backgrounds and successfully extracted absorption features of major chromophores including blood, water, and lipids. The results showed that the dual-spectrometer splicing method achieved smooth transitions in the overlapping region across different sites, validating its reliability. Spectral differences across sites were mainly characterized by hemoglobin absorption features in the visible region and water/lipid vibrational absorption features in the short-wave infrared region. These findings demonstrate the feasibility of dual-spectrometer splicing for broadband tissue spectral acquisition, enabling simultaneous capture of multi-component signals, and providing a new technical approach for non-invasive tissue composition analysis.