The purpose of this study was to investigate the accuracy of the airway volume measurement by a Regression Neural Network-based deep-learning model. A set of manually outlined airway data was set to build the algorithm for fully automatic segmentation of a deep learning process. Manual landmarks of the airway were determined by one examiner using a mid-sagittal plane of cone-beam computed tomography (CBCT) images of 315 patients. Clinical dataset-based training with data augmentation was conducted. Based on the annotated landmarks, the airway passage was measured and segmented. The accuracy of our model was confirmed by measuring the following between the examiner and the program: (1) a difference in volume of nasopharynx, oropharynx, and hypopharynx, and (2) the Euclidean distance. For the agreement analysis, 61 samples were extracted and compared. The correlation test showed a range of good to excellent reliability. A difference between volumes were analyzed using regression analysis. The slope of the two measurements was close to 1 and showed a linear regression correlation (r2 = 0.975, slope = 1.02, p < 0.001). These results indicate that fully automatic segmentation of the airway is possible by training via deep learning of artificial intelligence. Additionally, a high correlation between manual data and deep learning data was estimated.
30 April 2022 in Journal of the Korean Association of Oral and Maxillofacial Surgeons
This study aims to determine whether it can distinguish odontogenic keratocyst (OKC) and simple bone cyst (SBC) based solely on preoperative panoramic radiographs through a deep learning algorithm. (1) Methods: We conducted a retrospective analysis of patient data from January 2018 to December 2022 at Pusan National University Dental Hospital. This study included 63 cases of OKC confirmed by histological examination after surgical excision and 125 cases of SBC that underwent surgical curettage. All panoramic radiographs were obtained utilizing the Proline XC system (Planmeca Co., Helsinki, Finland), which already had diagnostic data on them. The panoramic images were cut into 299 × 299 cropped sizes and divided into 80% training and 20% validation data sets for 5-fold cross-validation. Inception-ResNet-V2 system was adopted to train for OKC and SBC discrimination. (2) Results: The classification network for diagnostic performance evaluation achieved 0.829 accuracy, 0.800 precision, 0.615 recall, and a 0.695 F1 score. (4) Conclusions: The deep learning algorithm demonstrated notable accuracy in distinguishing OKC from SBC, facilitated by CAM visualization. This progress is expected to become an essential resource for clinicians, improving diagnostic and treatment outcomes.
31 December 2022 in Journal of the Korean Association of Oral and Maxillofacial Surgeons