Mehrdad Saviz

Dr. Mehrdad Saviz


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014
Verified
Conference Paper
Closed access
RAReza Aminzadeh
Reza Aminzadeh
MSMehrdad Saviz
Mehrdad Saviz
ASAmir Ahmad Shishegar
Amir Ahmad Shishegar
Millimeter-wave reflectometry can be used as a non-invasive method for early detection of skin cancers. Less penetration and higher resolution are only some reasons to use mm-waves for skin cancer diagnosis. The dielectric parameters data of human skin at mm-wave frequencies are not widely addressed in the literature due to the expensive instruments and the complicated structure of human skin. Available dielectric properties of cancerous tissues in the literature are for other tissues rather than skin and are restricted to the frequencies below 20 GHz. In this paper, dielectric properties of healthy and malignant skin tissues were estimated in the range of 20-100 GHz by applying the effective medium theory. A stratified skin model and some skin tumors were presented. The possibility of mm-wave reflectometry for detection of skin cancers has also been studied. The results of this paper can be used as a theoretical basis for taking further steps in skin cancer research.

14 January 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GSGhazaleh Soleimani
Ghazaleh Soleimani
MSMehrdad Saviz
Mehrdad Saviz
MBMarom Bikson
Marom Bikson
FTFarzad Towhidkhah
Farzad Towhidkhah
RKRayus Kuplicki
Rayus Kuplicki
HEHamed Ekhtiari
Hamed Ekhtiari
Two challenges to optimizing transcranial direct current stimulation (tDCS) are selecting between, often similar, electrode montages and accounting for inter-individual differences in response. These two factors are related by how tDCS montage determines current flow through the brain considered across or within individuals. MRI-based computational head models (CHMs) predict how brain anatomy determines electric field (EF) patterns for a given tDCS montage. Because conventional tDCS produces diffuse brain current flow, stimulation outcomes may be understood as modulation of global networks. Therefore, we developed a network-led, rather than region-led, approach. We specifically considered two common “frontal” tDCS montages that nominally target the dorsolateral prefrontal cortex; asymmetric “unilateral” (anode/cathode: F4/Fp1) and symmetric “bilateral” (F4/F3) electrode montages. CHMs of 66 participants were constructed. We showed that cathode location significantly affects EFs in the limbic network. Furthermore, using a finer parcellation of large-scale networks, we found significant differences in some of the main nodes within a network, even if there is no difference at the network level. This study generally demonstrates a methodology for considering the components of large-scale networks in CHMs instead of targeting a single region and specifically provides insight into how symmetric vs asymmetric frontal tDCS may differentially modulate networks across a population.

1 April 2014 in Electronics Letters
Verified
Journal Article
Open access
PDF file
RAR. Aminzadeh
R. Aminzadeh
MSMehrdad Saviz
Mehrdad Saviz
ASA.A. Shishegar
A.A. Shishegar
Several phantoms have been fabricated for reflection measurements from human tissues in the range of 26.5–40 GHz. For the first time, a novel composition is introduced for fabrication of low‐cost simple tissue‐equivalent phantoms. The effective medium theory is applied to estimate the dielectric properties of phantoms consisting of polyethylene (PE) powder and the results are verified by dielectric properties measurement on the proposed phantoms. It is shown that mixing theory can estimate the dielectric properties of the PE‐based phantoms with minimum error. Therefore, the amount of the ingredients can be estimated theoretically.

10 June 2013 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
MSMehrdad Saviz
Mehrdad Saviz
OSOliver Spathmann
Oliver Spathmann
JSJoachim Streckert
Joachim Streckert
VHVolkert Hansen
Volkert Hansen
MCMarkus Clemens
Markus Clemens
Reza Faraji-DanaReza Faraji-Dana
Reza Faraji-Dana
This paper contributes to the topic of radiation safety in the THz band by providing theoretical estimations of the permissible incident power densities over 100 GHz-10 THz. Microthermal absorption has been characterized and a worst-case analysis has been done to provide thresholds for the tissue-internal electric field strength at THz frequencies. Dielectric models for the skin and the cornea of the eye as exposed surface tissues have been constructed and used to estimate the corresponding thresholds for incident power densities. The findings of this study shall be useful as a new theoretical framework for future studies related to THz radiation safety and regulation.

30 September 2015 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
OSOliver Spathmann
Oliver Spathmann
MZMartin Zang
Martin Zang
JSJoachim Streckert
Joachim Streckert
VHVolkert Hansen
Volkert Hansen
MSMehrdad Saviz
Mehrdad Saviz
MCMarkus Clemens
Markus Clemens
The ongoing development of new applications in the terahertz (THz) frequency range, such as wireless communication systems, full-body scanners, or other imaging procedures for biological and medical techniques, rapidly increases the number of persons who are potentially exposed to the electromagnetic radiation of those devices. Studies of thermal effects in humans caused by electromagnetic (EM) exposure with frequencies in the THz frequency range can rarely be found in the literature. In this paper, a method for the numerical computation of a potential thermal response in human skin due to EM fields between 0.1 and 10 THz is introduced. The method starts with the development of adequate simulation models for EM fields with penetration depths less than 1 mm. In a further step, it covers the provision of absolutely needed dielectric tissue parameters with help of the “effective medium theory,” since material properties above 100 GHz are not listed in the commonly consulted databases. The absorbed power in EM exposed human skin models of different complexity is calculated and subsequently used as heat source for temperature simulations. Spatial and time-dependent temperature profiles in the tissue are analyzed for transient and continuous exposures.

16 July 2013 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Closed access
PDF file
MSMehrdad Saviz
Mehrdad Saviz
LTLynda Mogouon Toko
Lynda Mogouon Toko
OSOliver Spathmann
Oliver Spathmann
JSJoachim Streckert
Joachim Streckert
VHVolkert Hansen
Volkert Hansen
Reza Faraji-DanaReza Faraji-Dana
Reza Faraji-Dana