This study proposed a dynamic characteristic analytical method (ANM) of a composite box girder bridge with corrugated steel web (CBGCSW) by completely considering the impact of shear lag effect and accordion effect of corrugated steel webs. Based on energy principles and variational principles, a vibration differential equation and the natural boundary conditions of a CBGCSW were developed. The analytical calculation formula for solving the vibration differential equation was then obtained. The results calculated using the ANM agreed well with previous experimental results, which validated the correctness of ANM. To demonstrate the superiority of the ANM, the vibration frequencies of several abstract CBGCSWs with varying ratios of span–width, obtained using the elementary beam theory (EBT) and the finite element method (FEM), were compared with those obtained by ANM. The efficacy of the ANM was verified and some meaningful conclusions were drawn which are helpful to relevant engineering design, such as the observation that a higher natural vibration frequency and smaller span–width ratio significantly magnified the shear lag effect of CBGCSW. The first five-order natural vibration frequencies of the CBGCSW were significantly lower than those of the composite box girder bridge with general steel web (CBGGSW), which indicates that the impact of the accordion effect is significant.
1 September 2018 in Journal of Engineering Mechanics
This paper introduces a novel approach based on dimensional analysis for designing explicit displacement algorithms for use in analyzing nonlinear structural dynamics problems. Using this approach, a one-parameter family of three-step unconditionally stable explicit displacement algorithms with controllable numerical energy dissipation, the CQ-3 method, is developed. The proposed method is promising for solving nonlinear structural dynamics problems with its properties of unconditional stability; explicit formulations of both displacement and velocity; controllable numerical dissipation; second-order time accuracy for displacement, velocity, and acceleration; one solver within one time step; and no overshoot for both displacement and velocity. Numerical examples are presented to demonstrate the potential of the proposed method.
30 December 2010 in Journal of Central South University of Technology
Aiming to solve the problems that a wind turbine foundation with a foundation pipe may suffer from grouting, where the concrete around the interface collapses and the interface disintegrates under a long-term wind load, a kind of wind turbine foundation with a constrained structural shear connector is proposed. In this article, the scaling model tests and a finite element simulation of a traditional stud foundation pipe, perforated steel shear connector foundation pipe, and three groups of constrained structural shear connector foundation pipes with different anchored depths are presented. The force transmission mechanism and damage mechanism of constrained structural shear connector wind turbine foundations are revealed, and the shear resistance of a constrained structural shear connector is analyzed. The influences of buried depth and other parameters on the mechanical properties of the shear connector are also investigated. The results show that the constrained structural shear connector has the advantages of stronger interfacial stiffness and significant force transfer and diffusion, and can more effectively connect the foundation pipe and concrete foundation to work together. It can give full play to the material advantages of concrete and reinforcements, and effectively improve the embedded stiffness and durability of concrete foundations. It can solve the problem of cracks in concrete caused by local pressure. At the same time, it is suggested that the diameter of the surrounding concrete should be in the range of 3 to 4 D, and the embedment depth of the stud should not be less than 0.4 D to give full play to the performance of the constrained structural shear connector.