Jiayuan Gao

Dr. Jiayuan Gao

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PGPingjuan Ge
Pingjuan Ge
CTChunming Tu
Chunming Tu
Fan XiaoFan Xiao
Fan Xiao
Qi GuoQi Guo
Qi Guo
Jiayuan GaoJiayuan Gao
Jiayuan Gao
Under fault conditions, virtual synchronous generators (VSGs) are prone to lose transient stability, similar to synchronous generators. However, the existing studies on VSG transient stability are not comprehensive. The transient characteristics of VSGs are highly affected by control parameters, but the transient models of VSGs in existing studies are overly simplified. In addition, the critical clearing angle (CCA) and critical clearing time (CCT) are two indices used to measure the transient stability of a system, but there are few studies that consider both CCA and CCT. In this article, we analyze the CCA and CCT quantitatively to describe the transient stability boundary of a VSG under different control parameters and fault conditions. Then, an equal proportional area criterion is proposed to provide guidance for the control of virtual inertia in the VSG. Based on a theoretical analysis, a transient control method for a VSG is proposed, which can improve the transient stability of the VSG in terms of both CCA and CCT. Finally, simulation and experimental tests are performed to validate the correctness of the theoretical analysis and the proposed method.

10 June 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CTChunming Tu
Chunming Tu
Jiayuan GaoJiayuan Gao
Jiayuan Gao
FXFan Xiao
Fan Xiao
Qi GuoQi Guo
Qi Guo
Fei JiangFei Jiang
Fei Jiang
The stability of the grid-connected inverter (GCI) system in weak grids is deteriorated due to the asymmetric positive-feedback loops (APFLs) introduced by the phase-locked loop (PLL) structure. Under the same main circuit parameters and control loop parameters, the small-signal models of the GCI controlled in dq domain and αβ domain are constructed, respectively. Compared with the small-signal model of the GCI controlled in dq domain, the number of APFLs introduced by the PLL of GCI controlled in αβ domain is one less. Moreover, the mechanism why the stability of the GCI controlled in αβ domain is stronger than that controlled in dq domain is analyzed. Meanwhile, the influence degree and mechanism of the APFLs in different paths of the small-signal models for the stability of GCI are revealed for the first time. This lays a theoretical foundation for the analysis and design of asymmetric control strategies used to improve the stability of GCI in weak grids. Finally, simulations and experiments verify the correctness of the theoretical analysis.

9 October 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Qi GuoQi Guo
Qi Guo
CTChunming Tu
Chunming Tu
Fei JiangFei Jiang
Fei Jiang
RZRongwu Zhu
Rongwu Zhu
Jiayuan GaoJiayuan Gao
Jiayuan Gao
Fault current-limiting dynamic voltage restorers (FCL-DVRs), also named as dual-functional DVRs, involving both the fault current-limiting (FCL) and the voltage compensation (VC) function, have attracted more attention. However, in case of the FCL-DVR operating in VC mode, either the high capacity of storage system in the dc-link or the oversizing of power converter is needed, and in case of the FCL-DVR operating in FCL mode both the high dc-link voltage and the oversizing of power converter are needed. Thus, in order to avoid these drawbacks, an improved FCL-DVR, which consists of a LC filter coupled with series coupling capacitor (LCC) at the ac side is proposed in this paper. The improved FCL-DVR using energy-optimized control strategy can not only perform the dual functions well, but also achieve the capacity optimization of FCL-DVR key components. The operating principle and performance of the proposed FCL-DVR under FCL and VC mode are elaborated, respectively. The optimal design of LCC and selection of FCL branch are studied in detail to ensure high stability and reliability for the proposed FCL-DVR operating in both modes. The simulation and experimental results clearly validate the effectiveness of the proposed topology and method.

22 September 2025 in Electronics
Verified
Journal Article
Open access
PDF file
RZRunkun Zhan
Runkun Zhan
Jiayuan GaoJiayuan Gao
Jiayuan Gao
SHShuai Huang
Shuai Huang
BLBinyan Li
Binyan Li
Fei JiangFei Jiang
Fei Jiang
QWQianhong Wu
Qianhong Wu
Under the high penetration of new energy, multi-machine interconnected grid-connected inverters (GCIs) are prone to lose stability due to the interaction with the power grid. To enhance their adaptability to the grid, a stability improvement method for multi-machine interconnected GCI systems with flexible control bandwidth design is proposed. First, based on the design principles of the converter control bandwidth, the transfer function models of the voltage outer loop and current inner loop are constructed, and the inner and outer loop control bandwidths that meet the requirements are designed. Secondly, to mitigate the adverse effects caused by the interaction of control bandwidths among multi-machine interconnected inverters, By analyzing the influence mechanism of the inner and outer loop bandwidths on the stability of the multi-machine interconnection system under different ratios, a flexible control bandwidth allocation scheme for different inverters in the multi-machine interconnection scenario is designed., thereby enhancing the stability of multi-machine-interconnected GCI through differentiated control bandwidth design. Unlike methods that add extra control loops, the method proposed in this paper does not require sampling new physical variables or modifying the control structure. Instead, it only necessitates adjusting the controller parameters of the multi-machine interconnection system, specifically the optimized distribution of bandwidth, to enhance the stability of the multi-machine interconnection system. Finally, simulation results are presented to verify the correctness and effectiveness of the proposed control method.