Zhaochun Li

Dr. Zhaochun Li

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2023 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
THTianyi Hang
Tianyi Hang
YCYiming Chen
Yiming Chen
FYFuqiang Yin
Fuqiang Yin
JSJiahui Shen
Jiahui Shen
XLXiping Li
Xiping Li
JZJiajia Zheng
Jiajia Zheng

29 January 2018 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
ZLZhaochun Li
Zhaochun Li
YGYao Gong
Yao Gong
JWJiong Wang
Jiong Wang
This article presents an optimal control strategy with fuzzy compensation for a magnetorheological fluid damper in control of a full-scale gun recoil buffering system. The novel control strategy combines the optimal control, in which no measurement feedback needed and the fuzzy logic control which is independent of any theoretical model. The theoretical optimal controllable damping force rule, as a fail-safe control output when the measurement system fails under the extreme condition of impact loading, is derived from the analytical solution of the kinematic equation of the recoil system with a magnetorheological damper. A one-dimensional fuzzy controller and a two-dimensional fuzzy controller are both designed and performed by simulation in order to evaluate the effectiveness of fuzzy control strategy as compensation in the magnetorheological recoil system. A magnetorheological damper for the real firing impact loading is designed and manufactured. Furthermore, an experimental study is carried out to evaluate the optimal control strategy with fuzzy compensation for magnetorheological damper on a firing test rig. The experimental results indicate that the proposed control strategy in this article obtains better buffering performance comprehensively compared with the conventional control strategies.

4 July 2023 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
THTianyi Hang
Tianyi Hang
JZJiajia Zheng
Jiajia Zheng
YZYijie Zou
Yijie Zou
Shaohua JiangShaohua Jiang
Shaohua Jiang
YZYuchen Zhao
Yuchen Zhao
YCYiming Chen
Yiming Chen

26 September 2024 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
JZJiajia Zheng
Jiajia Zheng
CXChenhui Xu
Chenhui Xu
ZLZhihui Li
Zhihui Li
CGCheng Gu
Cheng Gu
XLXiping Li
Xiping Li
YCYiming Chen
Yiming Chen
Two-dimensional MXenes have gained tremendous attention in the domain of electromagnetic wave absorption (EWA) owing to their outstanding conductivity and unique layered structures. Nevertheless, the disadvantages of easy stacking and non-magnetic properties often lead to incoordinate impedance matching and a single EWA mechanism, making it difficult to obtain optimal EWA performance. Herein, inspired by the hierarchically coral-like architecture, we demonstrated a controllable embedding strategy for in situ growing bimetallic CoNi metal–organic framework (MOF) derived carbon composite materials (CoNi@C) on the interlaminations of layered MXene via solvothermal and subsequent high-temperature annealing processes. The resultant MXene/CoNi@C showed excellent EWA capabilities, which mainly benefitted from a harmonious dielectric-magnetic coupling network with numerous heterointerfaces and porous structures brought about by interlaced CoNi nanorods. As anticipated, an optimal minimum reflection loss of −66.4 dB at 9.5 GHz, corresponding to an effective absorption bandwidth of 3.2 GHz, could be obtained by adjusting the ratios of MXene and CoNi-MOFs. This study will propose a bioinspired structure design strategy for developing high-performance MXene-based absorbers.

17 May 2019 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
ZLZhaochun Li
Zhaochun Li
YGYao Gong
Yao Gong
The inherent hysteresis of magnetorheological fluid dampers is one of the main reasons which limit their applications. The hysteresis mainly caused from two aspects. One part of the hysteresis is between the damping force and the piston velocity, which induced from the friction force of the damper, the compressibility of the fluid, rheological behavior etc. Another part of the hysteresis is between the damping force and the control current, which induced from the ferromagnetic materials inside the MR fluid damper. The ferromagnetic hysteresis of the MR fluid damper has been paid little attention to for a long time. Currently, the MR fluid damper is applying to the field of high velocity or shock and impact loadings where ferromagnetic hysteresis reduces the performance of the control current which leads to worse performances of vibration or buffer. Hall sensors are embedded to the MR fluid damper in this paper so that the magnetic flux density of the damping channels can be measured in real time. The hysteresis loops of the damping channels are obtained by measuring the relationships of the magnetic flux densities and the control currents. Furthermore, a Jiles-Atherton (J-A) hysteresis model based on differential equations for the MR fluid damper is established. The J-A hysteresis model is according to the domain-wall theory so that it has clear physical meaning with a small number of parameters. The hysteresis model is simulated utilizing MATLAB/SIMULINK. The particle swarm optimization (PSO) is adopted to identify the parameters of the J-A hysteresis model. The results show that the hysteresis loops identified by PSO is more similar to the measured hysteresis loops compared with the traditional parameter identification method. The research in this paper on the characteristic and model of the ferromagnetic hysteresis of the MR fluid damper is benefit to decrease or eliminate the effects of hysteresis which can improve the performances of the MR fluid dampers.

5 December 2019 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
ZLZhaochun Li
Zhaochun Li
YGYao Gong
Yao Gong
SLSihao Li
Sihao Li
WWWanjun Wang
Wanjun Wang
The hysteresis non-linearity of a magnetorheological (MR) fluid damper is one of the main reasons to restrict it to be widely used in shock buffering fields. This research aims to reduce or eliminate the effect of the magnetic hysteresis of the MR damper. A magnetic hysteresis compensation control method is proposed and verified in this paper. Jiles-Atherton (J-A) model is employed to descript the hysteresis non-linearity between the adjustable damping force and the actual magnetic induction intensity in the effective damping channel of the MR fluid damper. The simulation of the magnetic compensation control system is performed to evaluate the effectiveness of the proposed method and the employed model. In order to obtain the actual magnetic induction intensity, a MR fluid damper embedded in a Hall sensor is designed and manufactured. The experimental study is carried out to verify the proposed PID control of hysteresis compensation method. Both the simulation results and the experimental results show the MR fluid damper employed proposed hysteresis compensation method with PID control can almost completely eliminate the effect of hysteresis under both low frequency and high frequency input. The experimental results indicate the hysteresis control system of MR fluid damper is of good dynamic performance which make it suitable for the shock buffering system. At last, a simulation model of the MR-damper-based impact buffer system with hysteresis compensation control is established to verify the buffer effect of the system. The output damping force of the MR impact buffer system indicates the buffer performance has been improved by employing the magnetic hysteresis compensation control method.