Trina Dutta

Dr. Trina Dutta

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2021
Verified
Book Chapter
Closed access
PDF file
TDTrina Dutta
Trina Dutta
HCHirok Chaudhuri
Hirok Chaudhuri
CMChiranjit Maji
Chiranjit Maji

1 May 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
SBSangita Bhattacharjee
Sangita Bhattacharjee
TDTrina Dutta
Trina Dutta
CBChiranjib Bhattacharjee
Chiranjib Bhattacharjee
In this work, removal of arsenic from contaminated water was carried out using coagulation followed by polyelectrolyte enhanced ultrafiltration (PEUF). Ferric chloride and polydiallyldimethylammonium chloride (polyDADMAC) were used as coagulant and cationic polyelectrolyte, respectively. In the first step, effect of coagulant concentration on removal of arsenic was studied and coagulant dosage was optimized. In the second set of study, a combination of low dose of coagulant and polyelectrolyte solution was used for treatment of arsenic contaminated water. The supernatant collected following coagulation was subjected to PEUF so as to remove the residual arsenate ions. Ultrafiltration (UF) was carried out in a tangential flow module fitted with 5 kD polyethersulfone (PES) membrane. During UF, influence of polyelectrolyte dosage and transmembrane pressure (TMP) on permeate flux and arsenic rejection were investigated and optimum values were reported. It was observed that small dose [1 mL PE (polyelectrolyte)/50 mL of sample] could effectively reduce the residual arsenic concentration below permissible maximum contaminant level of 10 ppb. A 99.2% rejection of arsenic was recorded during ultrafiltration at a TMP of 2.5 bar following treatment with 0.234 mM polyelectrolyte solution.

30 April 2024 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
TDTrina Dutta
Trina Dutta
HCHirok Chaudhuri
Hirok Chaudhuri

1 November 2012 in Carbohydrate Research
Verified
Journal Article
Closed access
SSSHINJINEE SENGUPTA
SHINJINEE SENGUPTA
SLSagar Lahiri
Sagar Lahiri
SBShakri Banerjee
Shakri Banerjee
TDTrina Dutta
Trina Dutta
TDTarun K. Dhar
Tarun K. Dhar
AGAnil K. Ghosh
Anil K. Ghosh

1 January 2020
Verified
Book Chapter
Closed access
TDTrina Dutta
Trina Dutta
ABAnanya Barman
Ananya Barman
GMGautam Majumdar
Gautam Majumdar

1 February 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
NMNeelanjan Mazumder
Neelanjan Mazumder
TDTrina Dutta
Trina Dutta
PDPalash Dutta
Palash Dutta
SSSneha Srimani
Sneha Srimani
Corona virus has so far infected more than 21 million people worldwide with a mortality rate of nearly 3-4%. In some countries, it given goes up as 10%. While lockdown has so far been the only practised measure to hold the spread of the virus, still rate of infection is steadily increasing. Vaccine and effective antidotes are still to come. In this scenario, effective testing only works as an eye opener and helps in strategizing further measures. However, the testing is still a concern especially in developing economies. How much testing required, what are the effective ways to test people and its associated cost are critical considerations for the authorities. In this paper, we are going to analyse trend of positive cases detected in various countries, requirement of testing based on population density and how effective this had been in adapting containment measures. Based on reach and cost constraints, testing at a mass level is exceedingly difficult. So, testing must happen among the most representative sample of the population and the amount of testing in a representative population has a significant role in extrapolating data well on the entire population. So, we will look at what is the optimum amount of testing required per million population by various countries (which would depend on the population and population density). However, this would still not address the exact requirement of optimum sampling frame as data to do that is not available.