Proper utilization of geothermal energy for power generation is still overlooked in India even after having enough potential as much as the equivalent to its other nonconventional energy resources. The source of geothermal energy is the decay of the radio-nuclei present inside the Earth’s crust apart from the primordial heat source. The noble gas 4He is also produced during the radioactive disintegration process. Therefore, measuring the amount of 4He gas along with some other geochemical parameters in an Indian geothermal area, the potential of the reservoir can be evaluated. Mathematical calculations relating to the radioactive disintegration to estimate the geothermal potential of Bakreswar geothermal reservoir utilizing the concept of the 4He exploration technique has been described here. The study showed that the heat (radiogenic) energy generated by the radioactive decay of 232Th, 238U, and 235U inside the reservoir was evaluated as 38 MW. This value raises to 76 MW when primordial heat is included. The detail calculations suggest that a Kalina cycle based binary power plant using ammonia–water mixture as working fluid is supposed to be installed at the identified locations with a drilling depth of about 1,100 m and the plant would be capable of delivering the power of 9.88 MW to 40.26 MW.
The stochastic nature of the human heart, a complex biological system, is evident from electrocardiogram (ECG) signals, which are weak, non-linear and non-stationary signals. These temporal variations of electromagnetic pulses emanated from the heart are instrumental in indicating the cardiac health. The Empirical Mode Decomposition (EMD) technique was employed in order to decompose a total of 64 ECG signal data of arrhythmic and normal subjects, obtained from widely used MIT-BIH databases, into a finite number of Intrinsic Mode Functions (IMFs). The rationale behind using this strategy was to extract non-linear features of ECG signals which are not explicitly expressed, while keeping the original signal unaltered. Following removal of non-stationary noises from the ECG signals by the Savitzky-Golay (SG) filter, popular non-linear parameter Hurst Exponent (H) was estimated for every IMF by employing the R/S technique. A distinct difference between H values of 1st IMFs between normal individuals and arrhythmia affected patients was identified. This observation was further validated through an age-based and gender-based analysis, which demonstrated a unique alteration pattern with age. The study showed 94.92% probability in detection of arrhythmia in a patient. Adopting this EMD-based procedure for ECG data analysis and disease prediction may assist in reducing our dependence on intuition-based diagnosis of ECG reports by medical practitioners and may provide novel insights into the functioning of the human heart which might help develop new biomedical strategies to combat cardiac disorders.