Lijie Zhao

Dr. Lijie Zhao


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
LWLu Wang
Lu Wang
Jinlong YuanJinlong Yuan
Jinlong Yuan
HXHaiyun Xia
Haiyun Xia
LZLijie Zhao
Lijie Zhao
YWYunbin Wu
Yunbin Wu
Marine mixed layer height (MLH) detection using a ship-borne coherent Doppler wind lidar (CDWL) based on a constant turbulent kinetic energy dissipation rate (TKEDR) threshold is realized and experimentally demonstrated. The MLH can be retrieved from the TKEDR estimated by the CDWL via setting an appropriate threshold. Here, the value of threshold is determined by a reference MLH retrieved from aerosol backscattered signal. The threshold of 10−4 m2 s−3 is found to be applicable in retrieving both inland and marine MLHs. In the experiments, to validate the reliability of the constant threshold, the MLH diurnal cycles at inland and marine sites are retrieved by using a ground-based CDWL. The MLH retrieval result at the marine site shows good agreement with radiosonde-derived MLH. After that, by using a ship-borne CDWL, the marine MLH along the ship’s route in South China Sea is successfully detected in real time.

11 May 2021 in Journal of Lightwave Technology
Verified
Journal Article
Open access
LZLijie Zhao
Lijie Zhao
CZChunbo Zhao
Chunbo Zhao
CXChuanqing Xia
Chuanqing Xia
ZZZhen Zhang
Zhen Zhang
TWTengfei Wu
Tengfei Wu
HXHaiyun Xia
Haiyun Xia
A femtosecond laser metrology with nanometer precision and dynamic range of centimeter incorporating time-stretch interferometry and phase delay retrieval method is proposed and experimentally demonstrated. Displacement encoded phase-sensitive temporal interferogram is generated when phase stabilized femtosecond laser pulses transmitting through a time-stretch interferometer. To avoid the chirp of temporal interferogram due to high-order dispersion, time-to-frequency mapping is established to transform the temporal interferogram to the spectral interferogram for high-speed detection. The phase delay of spectral interferogram corresponding to specific displacements is retrieved and accumulated for linear fitting. The fitted slope is the time delay between two arms in the interferometer therefore displacement can be calculated. For precision verification, the preset displacements are measured. Mean error and standard deviation are presented after sliding average of measured results in 4 μs.

27 April 2020 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
ZZZhen Zhang
Zhen Zhang
HXHaiyun Xia
Haiyun Xia
SYSaifen Yu
Saifen Yu
LZLijie Zhao
Lijie Zhao
Tianwen WeiTianwen Wei
Tianwen Wei
MLManyi Li
Manyi Li
Dual-comb spectroscopy is a promising method for precise optical spectrum analysis with fast data acquisition speed. Here, avoiding using a dual-comb source, femtosecond imbalanced time-stretch spectroscopy with a simple optical layout is proposed and demonstrated. Time-stretch interferometry from one femtosecond laser builds mapping from the optical frequency domain to the radio frequency regime. In experiment, the absorption line of a hydrogen cyanide cell is encoded in the probing arm of a Mach–Zehnder interferometer (MZI). The down-converted radio frequency comb is transformed from a periodically chirped waveform, which is the interferogram of the MZI with different dispersion values on two arms. In a single measurement, the optical frequency comb with a span of 112.5 GHz is down-converted to a range of about 20.8 GHz in the radio frequency domain with a comb spacing equal to the laser repetition frequency of 100 MHz. By turning the optical filter, a spectrum range around 2 THz is analyzed. The acquired optical spectrum resolution is 540 MHz.

28 July 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
LZLijie Zhao
Lijie Zhao
HXHaiyun Xia
Haiyun Xia
YHYihua Hu
Yihua Hu
TWTengfei Wu
Tengfei Wu
ZZZhen Zhang
Zhen Zhang
TLTiancheng Luo
Tiancheng Luo
A real-time lidar with 0.1 mega-hertz update rate and few-micrometer resolution incorporating dispersive Fourier transformation and instantaneous microwave frequency measurement is proposed and demonstrated. As a femtosecond laser pulse passing through an all-fiber Mach-Zehnder interferometer, where the detection light beam is inserted into the optical path of one arm, the displacement is encoded to the frequency variation of the temporal interferogram. To deal with the challenges in storage and real-time processing of the microwave pulse generated on a photodetector, we turn to microwave photonic signal processing. A carrier wave is modulated by the time-domain interferogram using an intensity modulator. After that, the frequency variation of the microwave pulse is uploaded to the first order sidebands. Finally, the frequency shift of the sidebands is turned into transmission change through a symmetric-locked frequency discriminator. In experiment, a real-time ranging system with adjustable dynamic range and detection sensitivity is realized by incorporating a programmable optical filter. Standard deviation of 7.64 μm, overall mean error of 19.10 μm over 15 mm detection range and standard deviation of 37.73 μm, overall mean error of 36.63 μm over 45 mm detection range are realized, respectively.

5 August 2020 in arXiv
Verified
Preprint
Open access
PDF file
LZLijie Zhao
Lijie Zhao
HXHaiyun Xia
Haiyun Xia
YHYihua Hu
Yihua Hu
TWTengfei Wu
Tengfei Wu
ZZZhen Zhang
Zhen Zhang
TLTiancheng Luo
Tiancheng Luo
A real-time ranging lidar with 0.1 Mega Hertz update rate and few-micrometer resolution incorporating dispersive Fourier transformation and instantaneous microwave frequency measurement is proposed and demonstrated. As time-stretched femtosecond laser pulse passing through an all-fiber Mach-Zehnder Interferometer, where the detection light beam is inserted into the optical path of one arm, the displacement is encoded to the frequency variation of the temporal interferogram. To deal with the challenges in storage and real-time processing of the microwave pulse generated on a photodetector, we turn to all-optical signal processing. A carrier wave is modulated by the time-domain interferogram using an intensity modulator. After that, the frequency variation of the microwave pulse is uploaded to the first order sidebands. Finally, the frequency shift of the sidebands is turned into transmission change through a symmetric-locked frequency discriminator. In experiment, A real-time ranging system with adjustable dynamic range and detection sensitivity is realized by incorporating a programmable optical filter. Standard deviation of 7.64 {\mu}m, overall mean error of 19.10 {\mu}m over 15 mm detection range and standard deviation of 37.73 {\mu}m, overall mean error of 36.63 {\mu}m over 45 mm detection range are obtained respectively.