Jinxin Ouyang

Dr. Jinxin Ouyang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2024 in Electronics
Verified
Journal Article
Open access
PDF file
JOJinxin Ouyang
Jinxin Ouyang
YCYujie Chen
Yujie Chen
XPXinyu Pan
Xinyu Pan
YDYanbo Diao
Yanbo Diao
Commutation failures in line commuted converter-based high voltage direct current (LCC-HVDC) transmission systems leads to an increase in the converter bus voltage of the rectifier station, thus resulting in AC transient overvoltage in the sending-end grid. The transient overvoltage could lead to the disconnection of renewable energy generation and threaten the stable operation of the sending-end grid. However, the influences of the coupling between AC and DC systems caused by the interaction between the active and reactive power of the sending-end grid, the AC bus voltage of the rectifier station, and the DC current are ignored. The AC transient overvoltage cannot be accurately suppressed. Therefore, in this study, the transient voltage characteristics of the rectifier station under a commutation failure of the inverter station are analyzed. The influence of LCC-HVDC control on the AC bus voltage of a rectifier station through the active and reactive power of the rectifier station is analyzed. A dynamic model of the AC bus voltage of a rectifier station under an AC-DC system coupling is established. The calculation method of the command value of the DC current of the rectifier station is proposed by a predictive control model, and an improved suppression method for AC transient overvoltage is proposed. The case studies show that the accuracy and effectiveness of the suppression of AC transient overvoltage are improved by considering the coupling between AC and DC systems.

1 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JOJinxin Ouyang
Jinxin Ouyang
FMFan Mo
Fan Mo
FHFei Huang
Fei Huang
YCYujie Chen
Yujie Chen
In modern power systems, distributed generation (DG) clusters such as wind and solar resources are increasingly being integrated into active distribution networks through DG cluster control, which enhances the economic efficiency and adaptability of the DGs. However, cyber attacks on cyber–physical systems (CPS) may disable control links within the DG cluster, leading to the loss of control over slave DGs and resulting in power deficits, thereby threatening system stability. Existing CPS security assessment methods have limited capacity to capture cross-domain propagation effects caused by cyber attacks and lack a comprehensive evaluation framework from the attacker’s perspective. This paper establishes a CPS system model and control–communication framework and then analyzes the cyber–physical interaction characteristics under DG cluster control. A logical model of cyber attack strategies targeting DG cluster inverters is proposed. Based on the control topology and master–slave logic, a probabilistic failure model for DG cluster control is developed. By considering power deficits at cluster point of common coupling (PCC) and results in internal network of the DG cluster, a physical consequence quantification method is introduced. Finally, a cyber risk assessment method is proposed for DG cluster control under cyber attacks. Simulation results validate the effectiveness of the proposed method.