Youssef Sabba Tayah

Dr. Youssef Sabba Tayah

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2025 in Vision
Verified
Journal Article
Open access
PDF file
DTDavid Tayah
David Tayah
Ricardo Noguera LouzadaRicardo Noguera Louzada
Ricardo Noguera Louzada
PMPedro Lucas Machado Magalhães
Pedro Lucas Machado Magalhães
YTYoussef Sabba Tayah
Youssef Sabba Tayah
Dillan Cunha AmaralDillan Cunha Amaral
Dillan Cunha Amaral
MAMilton Ruiz Alves
Milton Ruiz Alves
This study evaluates the ability of the QuickSee Free (QSF) portable autorefractor (PlenOptika) to detect and measure refractive error compared to subjective clinical refractometry (SCR) in a Brazilian adult population in a low-resource setting in Amazonas. A total of 100 participants aged 18–65 years underwent visual acuity screening and autorefraction with and without cycloplegia using the QSF, alongside a complete ophthalmic examination including SCR. Refractive error measurements included spherical component (SC), cylindrical component (CC), cylindrical axis (CA), spherical equivalent (SE), and vector powers (MV90 and MV135). Accuracy was assessed for hyperopia ≥ +2.00 D, myopia ≤ −0.75 D, astigmatism ≥ 1.00 DC, and anisometropia ≥ 1.00 D using receiver operating characteristic (ROC) curve analysis. The area under the curve for detecting significant refractive errors ranged from 0.538 to 0.930. The mean difference between QSF without cycloplegia and SCR was −1.08 ± 1.17 D for SC and −1.15 ± 1.15 D for SE (p < 0.0001), and with cycloplegia, it was −0.81 ± 1.07 D and −0.83 ± 1.02 D, respectively. The QSF exhibited a moderate negative bias for both SC and SE with and without cycloplegia, underestimating these values, but it showed good predictability for detecting refractive errors in a low-resource setting.

21 October 2026 in Revista Brasileira de Oftalmologia
Verified
Journal Article
Open access
PDF file
DTDavid Tayah
David Tayah
Ricardo Noguera LouzadaRicardo Noguera Louzada
Ricardo Noguera Louzada
DDDaniel Oliveira Dantas
Daniel Oliveira Dantas
Dillan Cunha AmaralDillan Cunha Amaral
Dillan Cunha Amaral
YTYoussef Sabba Tayah
Youssef Sabba Tayah
MAMilton Ruiz Alves
Milton Ruiz Alves
Objective: To compare refractive measurements obtained with the QuickSee Free™ (QSFree) wavefront autorefractor, with and without a +2.00 D fogging lens, against subjective clinical refractometry (SCR) under cycloplegia in schoolchildren aged 7 to 17 years. Methods: One hundred right eyes from 100 healthy Brazilian schoolchildren were evaluated using QSFree without cycloplegia, QSFree with a +2.00 D fogging lens, QSFree under cycloplegia, and SCR under cycloplegia. Refractions were converted into spherical equivalent (SE) and astigmatic vector components projected onto the [...] ABSTRACT Objective: To compare refractive measurements obtained with the QuickSee Free™ (QSFree) wavefront autorefractor, with and without a +2.00 D fogging lens, against subjective clinical refractometry (SCR) under cycloplegia in schoolchildren aged 7 to 17 years. Methods: One hundred right eyes from 100 healthy Brazilian schoolchildren were evaluated using QSFree without cycloplegia, QSFree with a +2.00 D fogging lens, QSFree under cycloplegia, and SCR under cycloplegia. Refractions were converted into spherical equivalent (SE) and astigmatic vector components projected onto the