Matteo Borghesi

Dr. Matteo Borghesi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
CGClaudio Guarcello
Claudio Guarcello
GAGuerino AVALLONE
Guerino AVALLONE
CBCarlo Barone
Carlo Barone
MBMatteo Borghesi
Matteo Borghesi
SCSilvia Capelli
Silvia Capelli
MZMario Zannoni
Mario Zannoni
The recent developments in quantum technologies, as well as advanced detection experiments, have raised the need to detect extremely weak signals in the microwave frequency spectrum. To this aim, the Josephson travelling wave parametric amplifier, a device capable of reaching the quantum noise limit while providing a wide bandwidth, has been proposed as a suitable cryogenic front-end amplifier. This work deals with the numerical study of a Josephson travelling wave parametric amplifier, without approximations regarding the nonlinearity of the key elements. In particular, we focus on the investigation of the system of coupled nonlinear differential equations representing all the cells of the Josephson travelling wave parametric amplifier, with proper input and output signals at the boundaries. The investigation of the output signals generated by the parametric amplification process explores the phase-space and the Fourier spectral analysis of the output voltage, as a function of the parameters describing the pump and signal tones that excite the device. Beside the expected behavior, i.e., the signal amplification, we show that, depending on the system operation, unwanted effects (such as pump tone harmonics, incommensurate frequency generation, and noise rise), which are not accounted for in simple linearized approaches, can be generated in the whole nonlinear system.

25 January 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Sergio  PaganoSergio Pagano
Sergio Pagano
CBCarlo Barone
Carlo Barone
MBMatteo Borghesi
Matteo Borghesi
WCW. Chung
W. Chung
GCG. Carapella
G. Carapella
AVANDREA VINANTE
ANDREA VINANTE
Ultralow-noise microwave amplification and detection play a central role in different applications, going from fundamental physics experiments to the deployment of quantum technologies. In many applications the necessity of reading multiple detectors, or cavities or qubits, calls for large bandwidth amplifiers with the lowest possible noise. Current technologies are based on High Electron Mobility Transistors and Josephson Parametric Amplifiers. Both have limitations, the former in terms of the minimum noise, the latter in terms of bandwidth. Superconducting Traveling Wave Parametric Amplifiers (TWPAs) have the potential of offering quantum limited noise and large bandwidth. These amplifiers are based on the parametric amplification of microwaves traveling along a transmission line with embedded nonlinear elements. We are developing superconducting TWPAs based both on Josephson junction arrays (Traveling Wave Josephson Parametric Amplifiers) and on nonlinear kinetic inductance (Dispersion Engineered Traveling Wave Kinetic Inductance Amplifiers). Our goal is to achieve large bandwidth (in the 5 to 10 GHz range), large gain (more than 20 dB), large saturation power (more than −50 dBm), and near quantum limited noise (noise temperature less than 600 mK). Current achievements in the design and development of the high performance TWPAs are here reported and discussed, together with current limitations and possible future developments.

1 May 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
MBM. Beretta
M. Beretta
FHF. Houria
F. Houria
FFF. Ferraro
F. Ferraro
BDBasilico Davide
Basilico Davide
ABA. Brigatti
A. Brigatti
LVL. Votano
L. Votano
JUNO is a huge neutrino detector that will use 20 kton of organic liquid scintillator as its detection medium. The scintillator is a mixture of linear alkyl benzene (LAB), 2.5 g/L of 2,5-diphenyloxazole (PPO) and 3 mg/L of 1,4-Bis(2-methylstyryl)benzene (Bis-MSB). The main goal of JUNO is to determine the Neutrino Mass Ordering [1,2,3]. In order to achieve this purpose, good energy and position reconstruction is required, hence a complete understanding of the optical characteristics of the liquid scintillator is mandatory. In this paper we present the first measurements on the JUNO scintillator emission spectrum, absorption length and fluorescence time distribution performed respectively with a spectrofluorimeter, a spectrophotometer and a custom made setup of the liquid scintillator produced by the JUNO purification plants.

29 September 2025 in Physical Review Letters
Verified
Journal Article
Open access
BABradley Alpert
Bradley Alpert
MBM. Balata
M. Balata
DBD. T. Becker
D. T. Becker
DBD. A. Bennett
D. A. Bennett
MBMatteo Borghesi
Matteo Borghesi
LVL. R. Vale
L. R. Vale
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.

17 March 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MBMatteo Borghesi
Matteo Borghesi
BAB. Alpert
B. Alpert
MBM. Balata
M. Balata
DBD. Becker
D. Becker
DBD. Bennet
D. Bennet
LVL. Vale
L. Vale

25 October 2023 in Physica Scripta
Verified
Journal Article
Open access
PDF file
Federica MantegazziniFederica Mantegazzini
Federica Mantegazzini
FAFelix Ahrens
Felix Ahrens
MBMatteo Borghesi
Matteo Borghesi
PFPaolo Falferi
Paolo Falferi
FLFasolo Luca
Fasolo Luca
Andrea GiacheroAndrea Giachero
Andrea Giachero
A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) operated in a three-wave mixing fashion have demonstrated exceptional dynamic range and low-noise performance, approaching the quantum limit. These amplifiers can be fabricated using a single layer of a high kinetic inductance film as weakly dispersive artificial transmission lines, with the ability to control the phase-matched bandwidth through dispersion engineering. In this study, we present the optimisation of the rf sputter-deposition process of NbTiN films using a Nb80%Ti20% target, with the goal of achieving precise control over film characteristics, resulting in high kinetic inductance while maintaining a high transition temperature. The parameter landscape related to the different sputtering conditions, such as pressure, power, and nitrogen flow, has been explored and the film thickness has been used as a fine-tuning parameter to adjust the properties of the final NbTiN films used for the fabrication of KI-TWPAs. As a final result, we have obtained a NbTiN film with a kinetic inductance of 8.5 pH/sq which we have exploited to fabricate KI-TWPA prototype devices, showing promising amplification performance.