Accurate ranging using narrow-band ultrasonic transducers in small-scale environments can be used for indoor localization, human motion capture, and robotic navigation. One of the main problems faced by the ultrasonic localization systems is the ranging error due to the Doppler shift. Existing methods for Doppler correction employ a bank of matched filters at the receiver end which is computationally intense and complex. On the other hand, enabling multiple access for the ultrasonic localization systems is a challenging task due to multiple access interference. We propose a method to measure the range between multiple ultrasonic mobile nodes and static anchors in which we track the Doppler velocity and correct the errors between the transmitted and the received signals due to the Doppler effect. We utilize range-Doppler coupling to estimate the Doppler shift and adjust the range values calculated by correlation. In our method, a unique set of two chirp signals are used for each transmitter to get one sample reading. The simulation results show high ranging accuracy and robustness using the proposed method as the Doppler velocity increases. A pendulum experiment was conducted to validate the method using narrowband ultrasonic sensors. The multiple access interference problem was tackled by orthogonal coding, the chirp signals and Doppler correction. An improvement in the ranging accuracy was observed over traditional methods using chirp signals without Doppler correction.

1 July 2017
Verified
Conference Paper
Closed access
AKASHHAR KARALIKKADAN
ASHHAR KARALIKKADAN
CSCheong Boon Soh
Cheong Boon Soh
KKKeng He Kong
Keng He Kong
Analysis of bilateral gait symmetry and coordination is important in rehabilitation after lower-extremity trauma, prosthesis and neurovascular diseases. Moreover, it can act as a precursor of freezing of gait in Parkinson's disease. Current methods for gait symmetry analysis include Opto-electronic systems using multiple high-speed cameras, instrumented platforms etc. which are complex and costly. We propose a low-cost, wearable ultrasonic sensor network using readily available components, which is easy to use, portable and does not require complex calibration procedures. The system was tested on five healthy subjects and the results were compared with Motion Capture system. The experimental results show that the proposed system can be used to assess the human gait symmetry in a convenient and homely setup.

27 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AKASHHAR KARALIKKADAN
ASHHAR KARALIKKADAN
MKMohammad Omar Khyam
Mohammad Omar Khyam
CSCheong Boon Soh
Cheong Boon Soh
KKKeng He Kong
Keng He Kong
Ranging based on ultrasonic sensors can be used for tracking wearable mobile nodes accurately for a long duration and can be a cost-effective method for human movement analysis in rehabilitation clinics. In this paper, we present a Doppler-tolerant ultrasonic multiple access localization system to analyze gait parameters in human subjects. We employ multiple access methods using linear chirp wave-forms and narrow-band piezoelectric transducers. A Doppler shift compensation Technique is also incorporated without compromising on the tracking accuracy. The system developed was used for tracking the trajectory of both lower limbs of five healthy adults during a treadmill walk. An optical motion capture system was used as the reference to compare the performance. The average Root Mean Square Error values between the 3D coordinates estimated from the proposed system and the reference system while tracking both lower limbs during treadmill walk experiment by 5 subjects were found to be 16.75, 14.68 and 20.20 mm respectively along X, Y and Z-directions. Errors in the estimation of spatial and temporal parameters from the proposed system were also quantified. These promising results show that narrowband ultrasonic sensors can be utilized to accurately track more than one mobile node for human gait analysis.

18 August 2020 in IEEE Sensors Letters
Verified
Journal Article
Closed access
AKASHHAR KARALIKKADAN
ASHHAR KARALIKKADAN
MKMohammad Omar Khyam
Mohammad Omar Khyam
MNMd Noor-A-Rahim
Md Noor-A-Rahim
AJAruna Jayasuriya
Aruna Jayasuriya
CSCheong Boon Soh
Cheong Boon Soh
Narrowband ultrasonic sensors can be used for motion tracking and small scale localization. Moving sensor nodes emitting ultrasonic waves produce a Doppler shift in the received signals. Doppler correction methods in narrowband ultrasonic motion tracking systems are explained in this work. Two methods are suggested for Doppler compensation for small-scale localization using ultrasonic sensors. One of the methods requires a pilot carrier to be added to the transmitted signal and the other method exploits range-Doppler coupling for Doppler correction. In the simulation experiments, we compare the performance of the two methods with the traditional methods. We implement both the methods on hardware and compare the performance of the methods for ranging and localization in the presence of Doppler shift.

18 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AKASHHAR KARALIKKADAN
ASHHAR KARALIKKADAN
MKMohammad Omar Khyam
Mohammad Omar Khyam
CSCheong Boon Soh
Cheong Boon Soh
Gait analysis in unrestrained environments can be done with a single wearable ultrasonic sensor node on the lower limb and four fixed anchor nodes. The accuracy demanded by such systems is very high. Chirp signals can provide better ranging and localization performance in ultrasonic systems. However, we cannot neglect the multi-path effect in typical indoor environments for ultrasonic signals. The multi-path components closer to the line of sight component cannot be identified during correlation reception which leads to errors in the estimated range and which in turn affects the localization and tracking performance. We propose a novel method to reduce the multi-path effect in ultrasonic sensor networks in typical indoor environments. A gait analysis system with one mobile node attached to the lower limb was designed to test the performance of the proposed system during an indoor treadmill walking experiment. An optical motion capture system was used as a benchmark for the experiments. The proposed method gave better tracking accuracy compared to conventional coherent receivers. The static measurements gave 2.45 mm standard deviation compared to 10.45 mm using the classical approach. The RMSE between the ultrasonic gait analysis system and the reference system improved from 28.70 mm to 22.28 mm. The gait analysis system gave good performance for extraction of spatial and temporal parameters.