Cheong Boon Soh

Dr. Cheong Boon Soh


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Progress In Electromagnetics Research M
Verified
Journal Article
Open access
PDF file
JLJoshua Chong Yue Lai
Joshua Chong Yue Lai
CSCheong Boon Soh
Cheong Boon Soh
EGErry Gunawan
Erry Gunawan
KLKay Soon Low
Kay Soon Low
The paper describes pulse-based ultra-wideband (UWB) radar microwave imaging experiments for breast cancer detection using breast phantoms with dielectric properties mimicking the human breast. Three homogeneous and seven heterogeneous breast phantoms are designed with a series of dielectric permittivity and variability and are used in tumor detection experiments. The experiments are conducted in time-domain with pulse generator and real-time oscilloscope.

1 December 2008 in Journal of Telemedicine and Telecare
Verified
Journal Article
Closed access
LJLavanya Janardhanan
Lavanya Janardhanan
YLYung H Leow
Yung H Leow
MCMartin Tw Chio
Martin Tw Chio
YKYongmin Kim
Yongmin Kim
CSCheong Boon Soh
Cheong Boon Soh
We introduced a web-based teledermatology system, the distributed personal health information management system (DPHIMS), into a nursing home in Singapore. The introduction was conducted in two phases. Five staff nurses in Phase 1 and nine nurse aides in Phase 2 performed the data entry and uploaded digital images of the resident's skin condition. By the end of Phase 2, there were 50 residents registered with DPHIMS. The average age of the participants was 82 years and 84% were women. There were 31 first-time referral requests registered in the system during Phase 2. The average time taken to complete a referral request was 86 minutes. The average time taken by the dermatologist to prepare and submit a diagnosis/treatment report was 11 minutes. An online survey form was given to the nurses and the dermatologists to gauge their level of satisfaction and their experience of using DPHIMS. All the nurses said they would readily recommend DPHIMS to other nurses. Overall, the dermatologists felt that DPHIMS was helpful in obtaining specialist care for the residents. However, some skin conditions required a face-to-face consultation. Thus a mixture of face-to-face consultations and consultations via teledermatology may be necessary to provide complete diagnosis and treatment to patients. Our experience suggests that understanding and addressing the organizational concerns is as important as solving the technical problems.

20 August 2014 in Sensors
Verified
Journal Article
Open access
PDF file
YQYongbin Qi
Yongbin Qi
CSCheong Boon Soh
Cheong Boon Soh
EGErry Gunawan
Erry Gunawan
KLKay-Soon Low
Kay-Soon Low
RTRijil Thomas
Rijil Thomas
In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.

23 April 2015 in Sensors
Verified
Journal Article
Open access
PDF file
YQYongbin Qi
Yongbin Qi
CSCheong Boon Soh
Cheong Boon Soh
EGErry Gunawan
Erry Gunawan
KLKay-Soon Low
Kay-Soon Low
RTRijil Thomas
Rijil Thomas
This paper presents an unrestrained measurement system based on a wearable wireless ultrasonic sensor network to track the lower extremity joint and trunk kinematics during a squat exercise with only one ultrasonic sensor attached to the trunk. The system consists of an ultrasound transmitter (mobile) and multiple receivers (anchors) whose positions are known. The proposed system measures the horizontal and vertical displacement, together with known joint constraints, to estimate joint flexion/extension angles using an inverse kinematic model based on the damped least-squares technique. The performance of the proposed ultrasonic measurement system was validated against a camera-based tracking system on eight healthy subjects performing a planar squat exercise. Joint angles estimated from the ultrasonic system showed a root mean square error (RMSE) of 2.85° ± 0.57° with the reference system. Statistical analysis indicated great agreements between these two systems with a Pearson’s correlation coefficient (PCC) value larger than 0.99 for all joint angles’ estimation. These results show that the proposed ultrasonic measurement system is useful for applications, such as rehabilitation and sports.

27 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AKASHHAR KARALIKKADAN
ASHHAR KARALIKKADAN
MKMohammad Omar Khyam
Mohammad Omar Khyam
CSCheong Boon Soh
Cheong Boon Soh
KKKeng He Kong
Keng He Kong
Ranging based on ultrasonic sensors can be used for tracking wearable mobile nodes accurately for a long duration and can be a cost-effective method for human movement analysis in rehabilitation clinics. In this paper, we present a Doppler-tolerant ultrasonic multiple access localization system to analyze gait parameters in human subjects. We employ multiple access methods using linear chirp wave-forms and narrow-band piezoelectric transducers. A Doppler shift compensation Technique is also incorporated without compromising on the tracking accuracy. The system developed was used for tracking the trajectory of both lower limbs of five healthy adults during a treadmill walk. An optical motion capture system was used as the reference to compare the performance. The average Root Mean Square Error values between the 3D coordinates estimated from the proposed system and the reference system while tracking both lower limbs during treadmill walk experiment by 5 subjects were found to be 16.75, 14.68 and 20.20 mm respectively along X, Y and Z-directions. Errors in the estimation of spatial and temporal parameters from the proposed system were also quantified. These promising results show that narrowband ultrasonic sensors can be utilized to accurately track more than one mobile node for human gait analysis.

18 August 2020 in IEEE Sensors Letters
Verified
Journal Article
Closed access
AKASHHAR KARALIKKADAN
ASHHAR KARALIKKADAN
MKMohammad Omar Khyam
Mohammad Omar Khyam
MNMd Noor-A-Rahim
Md Noor-A-Rahim
AJAruna Jayasuriya
Aruna Jayasuriya
CSCheong Boon Soh
Cheong Boon Soh
Narrowband ultrasonic sensors can be used for motion tracking and small scale localization. Moving sensor nodes emitting ultrasonic waves produce a Doppler shift in the received signals. Doppler correction methods in narrowband ultrasonic motion tracking systems are explained in this work. Two methods are suggested for Doppler compensation for small-scale localization using ultrasonic sensors. One of the methods requires a pilot carrier to be added to the transmitted signal and the other method exploits range-Doppler coupling for Doppler correction. In the simulation experiments, we compare the performance of the two methods with the traditional methods. We implement both the methods on hardware and compare the performance of the methods for ranging and localization in the presence of Doppler shift.