Yinpeng Zhong

Prof. Dr. Yinpeng Zhong


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
YZYinpeng Zhong
Yinpeng Zhong
XYXia Yang
Xia Yang
In 2005, the FLASH soft X-ray free-electron laser (FEL) in Hamburg, Germany, achieved its first lasing, which began an intensive phase of global FEL construction. Subsequently, the United States, Japan, South Korea, China, Italy, and Switzerland all began building such photon facilities. Recently, the new generation of FEL has started to utilize superconducting acceleration technology to achieve high-repetition-rate pulse output, thereby improving experimental efficiency. Currently completed facility is the European XFEL, ongoing constructions are the LCLS-II in the United States and the SHINE facility in Shanghai, and the facility in preparation is the Shenzhen superconducting soft X-ray free-electron laser (S3FEL).These FEL facilities generate coherent and tunable ultrashort pulses ranging from the extreme ultraviolet to hard X-ray spectrum, which advances the FEL-based scattering techniques such as ultrafast X-ray scattering, spectroscopy, and X-ray nonlinear optics, thereby transforming the way we study correlated quantum materials on an ultrafast timescale.The self-amplified spontaneous emission (SASE) process in FEL leads to timing jitter between FEL pulses and the synchronized pump laser, influencing the accuracy of ultrafast time-resolved measurements. To address this issue, timing tools have been developed to measure these jitters and reindexed each pump-probe signal after measurement. This success enables ultrafast X-ray diffraction (UXRD) to be first realized, and a systematic study of Peierls distorted materials is demonstrated. In addition, the high flux of FEL pulses enables Fourier transform inelastic X-ray scattering (FT-IXS) method, which can extract the phonon dispersion curve of the entire Brillouin zone by performing the Fourier transform on the measured momentum dependent coherent phonon scattering signals, even when the system is in a non-equilibrium state.The UXRD is typically used to study ultrafast lattice dynamics, which requires hard X-ray wavelengths. In contrast, time resolved resonant elastic X-ray scattering (tr-REXS) in the soft X-ray regime has become a standard method of investigating nano-sized charge and spin orders in correlated quantum materials on an ultrafast time scale.In correlated quantum materials, the interplay between electron dynamics and lattice dynamics represents another important research direction. In addition to Zhi-Xun Shen's successful demonstration of the combined tr-ARPES and UXRD method at SLAC, this paper also reports the attempts to integrate UXRD with resonant X-ray emission spectroscopy (RXES) for the simultaneous measurement of electronic and lattice dynamics.Resonant inelastic X-ray scattering (RIXS) is a powerful tool for studying elementary and collective excitations in correlated quantum materials. However, in FEL-based soft X-ray spectroscopy, the wavefront tilt introduced by the widely used grating monochromators inevitably stretches the FEL pulses, which degrades the time resolution. Therefore, the new design at FEL beamlines adopts low line density gratings with long exit arms to reduce pulse stretch and achieve relatively high energy resolution. For example, the Heisenberg-RIXS instrument at the European XFEL achieves an energy resolution of 92 meV at the Cu L3 edge and approximately 150 fs time resolution.In recent years, scientists at SwissFEL’s Furka station have drawn inspiration from femtosecond optical covariance spectroscopy to propose a new method of generating two-dimensional time-resolved resonant inelastic X-ray scattering (2D tr-RIXS) spectra. This method involves real-time detection of single-shot FEL incident and scattered spectra, followed by deconvolution calculation to avoid photon waste and wavefront tilt caused by monochromator slits. The SQS experimental station at European XFEL, built in 2023, features a 1D-XUV spectrometer that utilizes subtle variations in photon energy absorption across the sample to induce spatial energy dispersion. Using Wolter mirrors, it directly images spatially resolved fluorescence emission from the sample onto the detector to generate 2D tr-RIXS spectra without the need for deconvolution. However, this design is limited to specific samples. Currently, the S3FEL under designing has a novel 2D tr-RIXS instrument that uses an upstream low line density grating monochromator to generate spatial dispersion of the beam spot, allowing the full bandwidth of SASE to project spatially dispersed photon energy onto the sample. Subsequently, an optical design similar to the 1D-XUV spectrometer will be employed to achieve 2D tr-RIXS spectra, thereby expanding the applicability beyond specific liquid samples. These new instruments are designed to minimize pulse elongation by fully utilizing SASE’s full bandwidth, approaching Fourier-transform-limited RIXS spectra in both time and energy resolution.Nonlinear X-ray optical techniques, such as sum-frequency generation (SFG) and second-harmonic generation, are adapting to X-ray wavelengths and opening up new avenues for detecting elementary excitations. The X-ray transient grating spectroscopy extends its capabilities to studying charge transport and spin dynamics on an ultrafast timescale. The future development of these scattering methods provides unique opportunities for detecting dynamical events in various systems, including surface and interface processes, chirality, nanoscale transport, and so-called multidimensional core-level spectroscopy.

13 October 2025 in Photonics
Verified
Journal Article
Open access
PDF file
WSWeihong Sun
Weihong Sun
CYChuan Yang
Chuan Yang
KHKai Hu
Kai Hu
Ye ZhuYe Zhu
Ye Zhu
CWChen Wu
Chen Wu
WZWeiqing Zhang
Weiqing Zhang
With the rapid development of X-ray free-electron lasers (XFELs), time-resolved resonant inelastic X-ray scattering (tr-RIXS) has attracted more attention. The preliminary designs of the tr-RIXS branchline and expected performance characteristics at the Shenzhen Superconducting Soft X-ray Free Electron Laser (S3FEL) are presented. A start-to-end simulation of the tr-RIXS branchline based on the 6-D phase space ray-tracing method of beamline simulation software package FURION was performed. The simulation design satisfies the key requirements of the tr-RIXS branchline, including spatial dispersion in the vertical dimension, temporal resolution, energy resolution, efficient utilization of SASE spectral photons, and spatial uniformity of the beam spot sizes across different wavelengths.

23 July 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
MWMeiyi Wu
Meiyi Wu
QLQinming Li
Qinming Li
MWMingchang Wang
Mingchang Wang
QZQinghao Zhu
Qinghao Zhu
JCJiandong Cai
Jiandong Cai
WZWeiqing Zhang
Weiqing Zhang
The damage threshold of an Au-coated flat mirror, one of the reflective optics installed on the FEL-2 beamline of the Dalian Coherent Light Source, China, upon far-UV free-electron laser irradiation is evaluated. The surface of the coating is characterized by profilometer and optical microscope. A theoretical approach of the phenomenon is also presented, by application of conventional single-pulse damage threshold calculations, a one-dimensional thermal diffusion model, as well as finite-element analysis with ANSYS.

3 September 2026 in Optics Express
Verified
Journal Article
Open access
CWChaoneng Wu
Chaoneng Wu
MRMabel Ruiz-Lopez
Mabel Ruiz-Lopez
BKBarbara Keitel
Barbara Keitel
ERErez N Ribak
Erez N Ribak
NRNiranjan K. Ramesha
Niranjan K. Ramesha
LLLu Li
Lu Li
The trend toward increasing numerical aperture (NA) in extreme ultraviolet (EUV) focusing necessitates precise, single-exposure characterization of the three-dimensional focal field. However, conventional Hartmann wavefront sensing is fundamentally challenged in the high-NA regime, where minor calibration errors couple into steep reference wavefronts, generating substantial fictitious phase artifacts. Here, we present a geometry-constrained reconstruction framework that robustly synthesizes the complete 3D focal volume of an NA = 0.19 Schwarzschild objective. Rather than relying on calibration-error-sensitive phase integration, we exploit the geometric signatures of the primary two-bounce beam and a parasitic four-bounce ghost beam specific to Schwarzschild-type concentric cavities. Resolving these geometrically defined constraints within an exact 3D non-linear ray-tracing framework allows for the deterministic extraction of the macroscopic optical alignment state, establishing a pathway for online objective adjustment. Coupling this resolved geometry with the measured intensity distribution accurately maps the principal fluence envelope. Propagating this stabilized field via a vectorial Debye integration generates a precise volumetric dose mapping. Sub-micron spatial registration of this reconstructed dose map with experimental ablation imprints robustly validates the model’s physical fidelity in predicting morphological damage thresholds. This approach broadens the usable scene for the Hartmann wavefront sensor into calibration-hostile, NA = 0.19 Schwarzschild objective systems, enabling single-exposure access to fluence-dependent damage evolution.

1 December 2025 in Review of Scientific Instruments
Verified
Journal Article
Open access
QZQinghao Zhu
Qinghao Zhu
JCJiandong Cai
Jiandong Cai
BSBaoning Sun
Baoning Sun
XYXia Yang
Xia Yang
MWMeiyi Wu
Meiyi Wu
YZYinpeng Zhong
Yinpeng Zhong
Gravity-induced surface deviations in bendable mirrors degrade the performance of Kirkpatrick–Baez focusing systems at synchrotron and free-electron-laser beamlines. Conventional gravity compensation models ignore the inactive end length introduced by end clamping in four-roll benders. This omission leads to a systematic mismatch between predicted and measured surface shapes. This study develops an analytical model with end-loss correction within the Euler–Bernoulli beam framework for bendable mirrors. The model provides closed-form expressions for the required moments, the symmetric support forces, and the associated optimal dimensionless parameters. Finite element analysis verifies the predictions across representative geometries and load cases. With end loss included, the root-mean-square slope deviation decreases by about one order of magnitude to below 20 nrad, which meets the requirements for diffraction-limited focusing. This work establishes a robust framework for high-precision bendable mirror systems, with clear potential to reduce tuning cost and improve beamline optical performance.

12 October 2026 in The European Physical Journal D
Verified
Journal Article
Closed access
PDF file
JGJian Gao
Jian Gao
AYAnzhou Yang
Anzhou Yang
QYQixuan Yuan
Qixuan Yuan
XYXia Yang
Xia Yang
DZDongfang Zhang
Dongfang Zhang
YZYinpeng Zhong
Yinpeng Zhong