Ehsan Mohseni

Dr. Ehsan Mohseni

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2024 in Ultrasonics
Verified
Journal Article
Open access
VTVedran Tunukovic
Vedran Tunukovic
SMShaun McKnight
Shaun McKnight
RPRichard Pyle
Richard Pyle
ZWZhiming Wang
Zhiming Wang
EMEhsan Mohseni
Ehsan Mohseni
TOTom O'Hare
Tom O'Hare
The use of Carbon Fibre Reinforced Plastic (CFRP) composite materials for critical components has significantly surged within the energy and aerospace industry. With this rapid increase in deployment, reliable post-manufacturing Non-Destructive Evaluation (NDE) is critical for verifying the mechanical integrity of manufactured components. To this end, an automated Ultrasonic Testing (UT) NDE process delivered by an industrial manipulator was developed, greatly increasing the measurement speed, repeatability, and locational precision, while increasing the throughput of data generated by the selected NDE modality. Data interpretation of UT signals presents a current bottleneck, as it is still predominantly performed manually in industrial settings. To reduce the interpretation time and minimise human error, this paper presents a two-stage automated NDE evaluation pipeline consisting of a) an intelligent gating process and b) an autoencoder (AE) defect detector. Both stages are based on an unsupervised method, leveraging density-based spatial clustering of applications with noise clustering method for robust automated gating and undefective UT data for the training of the AE architecture. The AE network trained on ultrasonic B-scan data was tested for performance on a set of reference CFRP samples with embedded and manufactured defects. The developed model is rapid during inference, processing over 2000 ultrasonic B-scans in 1.26 s with the area under the receiver operating characteristic curve of 0.922 in simple and 0.879 in complex geometry samples. The benefits and shortcomings of the presented methods are discussed, and uncertainties associated with the reported results are evaluated.

27 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MVMomchil Vasilev
Momchil Vasilev
CMCharles MacLeod
Charles MacLeod
CLCharalampos Loukas
Charalampos Loukas
Yashar JavadiYashar Javadi
Yashar Javadi
RVRandika K. W. Vithanage
Randika K. W. Vithanage
AGAnthony Gachagan
Anthony Gachagan
The growth of the automated welding sector and emerging technological requirements of Industry 4.0 have driven demand and research into intelligent sensor-enabled robotic systems. The higher production rates of automated welding have increased the need for fast, robotically deployed Non-Destructive Evaluation (NDE), replacing current time-consuming manually deployed inspection. This paper presents the development and deployment of a novel multi-robot system for automated welding and in-process NDE. Full external positional control is achieved in real time allowing for on-the-fly motion correction, based on multi-sensory input. The inspection capabilities of the system are demonstrated at three different stages of the manufacturing process: after all welding passes are complete; between individual welding passes; and during live-arc welding deposition. The specific advantages and challenges of each approach are outlined, and the defect detection capability is demonstrated through inspection of artificially induced defects. The developed system offers an early defect detection opportunity compared to current inspection methods, drastically reducing the delay between defect formation and discovery. This approach would enable in-process weld repair, leading to higher production efficiency, reduced rework rates and lower production costs.

1 October 2019 in Additive Manufacturing
Verified
Journal Article
Closed access
Yashar JavadiYashar Javadi
Yashar Javadi
CMCharles N. MacLeod
Charles N. MacLeod
SPStephen G. Pierce
Stephen G. Pierce
AGAnthony Gachagan
Anthony Gachagan
DLDavid Lines
David Lines
RSRiliang Su
Riliang Su

1 June 2020 in Materials & Design
Verified
Journal Article
Open access
Yashar JavadiYashar Javadi
Yashar Javadi
EMEhsan Mohseni
Ehsan Mohseni
CMCharles N. MacLeod
Charles N. MacLeod
DLDavid Lines
David Lines
MVMomchil Vasilev
Momchil Vasilev
AGAnthony Gachagan
Anthony Gachagan

28 December 2019 in Journal of Nondestructive Evaluation
Verified
Journal Article
Open access
PDF file
EMEhsan Mohseni
Ehsan Mohseni
HBHamid Habibzadeh Boukani
Hamid Habibzadeh Boukani
DFDemartonne Ramos França
Demartonne Ramos França
MVMartin Viens
Martin Viens
Applying life estimation approaches to determine in-service life of structures and plan the inspection schedules accordingly are becoming acceptable safety design procedures in aerospace. However, these design systems shall be fed with reliable parameters related to material properties, loading conditions and defect characteristics. In this context, the role of non-destructive (NDT) testing reliability is of high importance in detecting and sizing defects. Eddy current test (ECT) is an electromagnetic NDT method frequently used to inspect tiny surface fatigue cracks in sensitive industries. Owing to the new advances in robotic technologies, there is a trend to integrate the ECT into automated systems to perform NDT inspections more efficiently. In fact, ECT can be effectively automated as to increase the coverage, repeatability and scanning speed. The reliability of ECT scanning, however, should be thoroughly investigated and compared to conventional modes of applications to obtain a better understanding of the advantages and shortcomings related to this technique. In this contribution, a series of manual and automated ECT tests are carried out on a set of samples using a split-D reflection differential surface probe. The study investigates the level of noise recorded in each technique and discuss its dependency on different parameters, such as surface roughness and frequency. Afterwards, a description of the effect of crack orientation on ECT signal amplitude is provided through experimental tests and finite element simulations. Finally, the reliability of each ECT technique is investigated by means of probability of detection (POD) curves. POD parameters are then extracted and compared to examine the effect of scanning index, frequency and automation on detection reliability.

8 December 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RVRandika K. W. Vithanage
Randika K. W. Vithanage
EMEhsan Mohseni
Ehsan Mohseni
Zhen QiuZhen Qiu
Zhen Qiu
CMCharles MacLeod
Charles MacLeod
Yashar JavadiYashar Javadi
Yashar Javadi
AGAnthony Gachagan
Anthony Gachagan
Non-destructive inspection of multi-pass welds for defects is traditionally performed once all layers have been deposited and the sample is at ambient temperature and therefore can lead to complicated and expensive rework, reduced throughput and higher lead times. By performing inspection either as the weld is deposited, or between weld passes, it is possible to identify defects earlier in the process and rectify them. Traditional ultrasonic inspection is severely limited in this application due to the high temperatures associated with the welding process and therefore, the authors describe a novel high-temperature ultrasound phased array roller probe to perform robotically delivered in-process inspection of multipass welds. The new roller probe is able to operate at temperatures up to 350 °C and perform angled weld inspection using 55° transverse waves. The wheel probe's endless rotation enables continuous inspection and makes it well suited to integrate within automated environments commonly employed for high integrity multipass welding applications. The probe demonstrated capability to detect calibration side drilled holes at room temperature and artificial defects embedded into a real weld at high temperature. The experimental results indicate potential to industrialise this prototype in the future.