This study seeks to determine the efficacy of a novel, virtual reality (VR)-based sensorimotor assessment tool, VIST Neuro-ID, in comparison to the gold standard. This was achieved through computing common postural sway metrics, as well as comparing these metrics across population groups including sex and age (50–60 vs. 61–75). Sensorimotor assessments were conducted within the VIST Neuro-ID VR software while participants stood on a force plate. A proxy for center-of-pressure measurement was developed using the six-degree-of-freedom data collected from the head-mounted display used with the VR system. Moderate-to-high (r = 0.542–0.906) Pearson’s correlations were found between VIST Neuro-ID and the force plate for all eight postural sway metrics that were computed. Both systems detected significant differences (p < 0.05) across age groups for all metrics, except for two-dimensional path length from the force plate. Several significant differences were found across sexes, including AP and resultant sway velocity from the force plate, and resultant and AP root-mean-square from the HTC Vive Pro Eye. This indicates potential for VR to be used to collect vital postural sway metrics needed for assessing patient function, while also highlighting potential to identify balance patterns related to aging.
Accurate and unobtrusive measurement of upper-limb kinematics is critical for advancing wearable sensing technologies used in industrial ergonomics, human–machine interaction, and real-time biomechanics monitoring. This study evaluates the performance of two soft, flexible wearable sensors—BendLabs biaxial angular displacement sensors and StretchSense capacitive stretch sensors—for quantifying wrist and elbow motions during simulated dynamic industrial tasks. Wrist flexion–extension and radial–ulnar deviation were measured using BendLabs sensors mounted on the dorsal hand, while elbow flexion–extension was captured using StretchSense sensors positioned along the elbow joint. A multi-camera optical motion capture system served as the reference standard. Sensor data were preprocessed using baseline correction, smoothing, denoising, and normalized cross-correlation techniques to support temporal alignment with motion-capture recordings. Across all activities, the BendLabs sensors demonstrated moderate agreement with motion capture for wrist kinematics, with generally better performance for radial–ulnar deviation than for flexion–extension. StretchSense sensors demonstrated stronger agreement with motion capture for elbow flexion–extension, with performance that was generally consistent across task types. These findings support the feasibility of soft wearable sensors for capturing upper-limb kinematics during simulated occupational tasks and highlight their potential for integration into ergonomic assessment, occupational monitoring systems, and future industrial wearable platforms.