James L Weinstein

Dr. James L Weinstein

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2025 in Electronics
Verified
Journal Article
Open access
PDF file
DSDavid Saucier
David Saucier
KMKaitlyn Michelle McDonald
Kaitlyn Michelle McDonald
MMMichael Mydlo
Michael Mydlo
RBRachel Barber
Rachel Barber
EWEmily Salmon Wall
Emily Salmon Wall
JWJames L Weinstein
James L Weinstein
This study seeks to determine the efficacy of a novel, virtual reality (VR)-based sensorimotor assessment tool, VIST Neuro-ID, in comparison to the gold standard. This was achieved through computing common postural sway metrics, as well as comparing these metrics across population groups including sex and age (50–60 vs. 61–75). Sensorimotor assessments were conducted within the VIST Neuro-ID VR software while participants stood on a force plate. A proxy for center-of-pressure measurement was developed using the six-degree-of-freedom data collected from the head-mounted display used with the VR system. Moderate-to-high (r = 0.542–0.906) Pearson’s correlations were found between VIST Neuro-ID and the force plate for all eight postural sway metrics that were computed. Both systems detected significant differences (p < 0.05) across age groups for all metrics, except for two-dimensional path length from the force plate. Several significant differences were found across sexes, including AP and resultant sway velocity from the force plate, and resultant and AP root-mean-square from the HTC Vive Pro Eye. This indicates potential for VR to be used to collect vital postural sway metrics needed for assessing patient function, while also highlighting potential to identify balance patterns related to aging.

3 June 2026 in Electronics
Verified
Journal Article
Open access
PDF file
PTPurva Talegaonkar
Purva Talegaonkar
DSDavid Saucier
David Saucier
LKLaith Odeh Bani Khaled
Laith Odeh Bani Khaled
ETErin Tillery
Erin Tillery
ATAlana J. Turner
Alana J. Turner
RBReuben F. Burch
Reuben F. Burch
Accurate and unobtrusive measurement of upper-limb kinematics is critical for advancing wearable sensing technologies used in industrial ergonomics, human–machine interaction, and real-time biomechanics monitoring. This study evaluates the performance of two soft, flexible wearable sensors—BendLabs biaxial angular displacement sensors and StretchSense capacitive stretch sensors—for quantifying wrist and elbow motions during simulated dynamic industrial tasks. Wrist flexion–extension and radial–ulnar deviation were measured using BendLabs sensors mounted on the dorsal hand, while elbow flexion–extension was captured using StretchSense sensors positioned along the elbow joint. A multi-camera optical motion capture system served as the reference standard. Sensor data were preprocessed using baseline correction, smoothing, denoising, and normalized cross-correlation techniques to support temporal alignment with motion-capture recordings. Across all activities, the BendLabs sensors demonstrated moderate agreement with motion capture for wrist kinematics, with generally better performance for radial–ulnar deviation than for flexion–extension. StretchSense sensors demonstrated stronger agreement with motion capture for elbow flexion–extension, with performance that was generally consistent across task types. These findings support the feasibility of soft wearable sensors for capturing upper-limb kinematics during simulated occupational tasks and highlight their potential for integration into ergonomic assessment, occupational monitoring systems, and future industrial wearable platforms.