Hong Hua

Dr. Hong Hua

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
JLJiaxing Lu
Jiaxing Lu
XLXiaobing Liu
Xiaobing Liu
YZYongzhong Zeng
Yongzhong Zeng
BZBaoshan Zhu
Baoshan Zhu
Bo HuBo Hu
Bo Hu
HHHong Hua
Hong Hua
A combined numerical and experimental method study was performed to detect the inner flow state for a type of centrifugal pump. It was found that the inlet attack angles of blades in an impeller have a great influence on the flow instabilities in a centrifugal pump. The mechanism of the rotating stall in the impeller channel was explained. Meanwhile, flow state identification with vibration (FSIV) was proposed to detect the flow instabilities in a centrifugal pump. The relationship between the external vibration and the inner flow state has been established by FSIV. The characteristics and mechanism of the vibration produced by the flow instabilities in a centrifugal pump were investigated. It was found that the hump, the rotating stall, the backflow, the occurrence of unstable flow, and the cavitation in the centrifugal pump can be effectively detected by applying the vibration signals, which helps to obtain safe and steady operating conditions for the system.

28 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
JLJiaxing Lu
Jiaxing Lu
XLXiaobing Liu
Xiaobing Liu
YZYongzhong Zeng
Yongzhong Zeng
BZBaoshan Zhu
Baoshan Zhu
Bo HuBo Hu
Bo Hu
HHHong Hua
Hong Hua
In order to investigate the mechanism and the characteristics of the noise induced by unstable flow in a centrifugal pump, the internal flow characteristics in the pump were numerically researched, and the acoustic pressure fluctuations at the pump inlet and outlet were experimentally investigated. Obvious corresponding relationships between the flow instabilities, the cavitation and the noise were established. It was found that the rotating stall, the backflow, the hump, the occurrence of unstable flow and the cavitation in such a centrifugal pump were effectively detected through the noise, which could help to provide fundamental information on flow instabilities and guarantee safe and steady operating conditions for the system. The recirculation and prewhirl regions in the pump upstream pipe, which were caused by the backflow and the rotation of the impeller, presented the circumferential movement with a spiral shape, causing apparent broadband fluctuations at low frequency band of the acoustic pressure. The backflow and rotating stall could also result in broadband fluctuations of the pump outlet noise, which was distributed from 100 Hz to 150 Hz. Meanwhile, the broadband fluctuations of the pump outlet acoustic pressure distributed in the low frequency range, which was produced by the occurrence of cavitation, moved to the lower frequency band as the flow rate increased. The enhanced broadband fluctuations of the pump inlet and outlet noise distributed from 1 kHz to 6 kHz were caused by the coupling between the cavitation-induced noise and the system-produced noise. The broadband fluctuations of the pump inlet noise distributed between 6 kHz and 9 kHz were regarded as the typical frequency band of cavitation in the centrifugal pump.

1 February 2025 in Physics of Fluids
Verified
Journal Article
Closed access
HWHaiqi Wang
Haiqi Wang
JPJiayang Pang
Jiayang Pang
ZLZhenming Lai
Zhenming Lai
LGLongchao Gan
Longchao Gan
DHDong Huang
Dong Huang
XLXiaobing Liu
Xiaobing Liu
Modern power systems, energy sources, often necessitate that hydropower turbines function across a broad load range. This requirement presents significant challenges to the stable operation of turbines designed based on rated operating parameters. This study utilizes numerical simulations and experimental tests to investigate the flow characteristics, pressure pulsation, and vibration of a Francis turbine in a hydropower station within a hydro-photovoltaic hybrid system under varying load conditions. The findings indicate that with a rated head of 132 m, an intermediate head of 145 m, and a maximum head of 156.5 m, the internal flow pattern of the turbine becomes chaotic when the opening degree is between 20% and 40%. In contrast, when the opening degree ranges from 70% to 100%, the extent of eddy currents around the runner blades decreases, leading to a more stable flow pattern. Severe cavitation of the runner blades occurs at 20% opening when the water head is between 132 and 145 m. However, at a water head of 156.5 m, only minor cavitation is observed at the runner's inlet edge. As the guide vane opening increases, the primary cavitation zone shifts from the interior of the runner to the lower end of the discharge cone. Pressure pulsation and vibration tests suggest that operation should be minimized in the 55% to 70% opening range when the rated head is 132 m. To maintain efficient and stable operation of the power station unit, it is recommended that operating conditions be maintained within the 70% to 80% opening range. These findings offer a technical support and a theoretical framework for expanding the stable operation range of hydraulic turbines.

19 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HHHong Hua
Hong Hua
ZZZhizhong Zhang
Zhizhong Zhang
XLXiaobing Liu
Xiaobing Liu
WDWanquan Deng
Wanquan Deng
Hydraulic turbine governor servomotors in wind solar hydro complementary energy systems face significant fatigue failure challenges due to high-frequency regulation. This study develops an intelligent fatigue monitoring and prediction system based on strain sensors, specifically designed for the frequent regulation requirements of complementary systems. A multi-point monitoring network was constructed using resistive strain sensors, integrated with temperature and vibration sensors for multimodal data fusion. Field validation was conducted at an 18.56 MW hydroelectric unit, covering guide vane opening ranges from 13% to 63%, with system response time <1 ms and a signal-to-noise ratio of 65 dB. A simulation model combining sensor measurements with finite element simulation was established through fine-mesh modeling to identify critical fatigue locations. The finite element analysis results show excellent agreement with experimental measurements (error < 8%), validating the simulation model approach. The fork head was identified as the critical component with a stress concentration factor of 3.4, maximum stress of 51.7 MPa, and predicted fatigue life of 1.2 × 106 cycles (12–16 years). The cylindrical pin shows a maximum shear stress of 36.1 MPa, with fatigue life of 3.8 × 106 cycles (16–20 years). Monte Carlo reliability analysis indicates a system reliability of 51.2% over 20 years. This work provides an effective technical solution for the predictive maintenance and digital operation of wind solar hydro complementary systems.

14 December 2025 in Symmetry
Verified
Journal Article
Open access
PDF file
HHHong Hua
Hong Hua
ZZZhizhong Zhang
Zhizhong Zhang
XLXiaobing Liu
Xiaobing Liu
HZHaiku Zhang
Haiku Zhang
Flexible grid regulation necessitates Francis turbines to operate at heads of 120–180 m (compared to the rated head of 154.6 m), breaking the designed rotational symmetry and inducing hydraulic instabilities that threaten structural integrity and operational reliability. This study presents extensive field measurements of pressure pulsations in a 600 MW prototype Francis turbine operating at heads of 120–180 m and loads of 20–600 MW across 77 operating conditions (7 head levels × 11 load points). We strategically positioned high-precision piezoelectric pressure sensors at three critical locations—volute inlet, vaneless space, and draft tube cone—to capture the amplitude and frequency characteristics of symmetry-breaking phenomena. Advanced signal processing revealed three distinct mechanisms with characteristic pressure pulsation signatures: (1) Draft tube rotating vortex rope (RVR) represents spontaneous breaking of axial symmetry, exhibiting helical precession at 0.38 Hz (approximately 0.18 fn, where fn = 2.08 Hz) with maximum peak-to-peak amplitudes of 108 kPa (87% of the rated pressure prated = 124 kPa) at H = 180 m and P = 300 MW, demonstrating approximately 70% amplitude reduction potential through load-based operational strategies. (2) Vaneless space rotor-stator interaction (RSI) reflects periodic disruption of the combined C24 × C13 symmetry at the blade-passing frequency of 27.1 Hz (Nr × fn = 13 × 2.08 Hz), reaching peak amplitudes of 164 kPa (132% prated) at H = 180 m and P = 150 MW, representing the most severe symmetry-breaking phenomenon. (3) Volute multi-point excitation exhibits broadband spectral characteristics (4–10 Hz) with peak amplitudes of 146 kPa (118% prated) under small guide vane openings. The spatial amplitude hierarchy—vaneless space (164 kPa) > volute (146 kPa) > draft tube (108 kPa)—directly correlates with the local symmetry-breaking intensity, providing quantitative evidence for the relationship between geometric symmetry disruption and hydraulic excitation magnitude. Systematic head-dependent amplitude increases of 22–43% across all monitoring locations are attributed to effects related to Euler head scaling and Reynolds number variation, with the vaneless space demonstrating the highest sensitivity (0.83 kPa/m, equivalent to 0.67% prated/m). The study establishes data-driven operational guidelines identifying forbidden operating regions (H = 160–180 m, P = 20–150 MW for vaneless space; H = 160–180 m, P = 250–350 MW for draft tube) and critical monitoring frequencies (0.38 Hz for RVR, 27.1 Hz for RSI), providing essential reference data for condition monitoring systems and operational optimization of large Francis turbines functioning as flexible grid-regulating units in renewable energy integration scenarios.

28 June 2018 in Mechanics
Verified
Journal Article
Open access
PDF file
HHHong Hua
Hong Hua
ZZZhang Zhi-Zhong
Zhang Zhi-Zhong
XLXiaobing Liu
Xiaobing Liu
YZYongzhong Zeng
Yongzhong Zeng
HWHuiyan Wang
Huiyan Wang
With the use of RNG k-ε turbulence model, SIMPLEC algorithm and CFD software, the turbulent flow in an axial flow impeller was numerically simulated in the clear water (single-phase) and the sandy water (solid-liquid two-phase) conditions. The distributions of solid concentration, velocity and pressure on the impeller of an axial flow pump were analyzed at the same particle diameter but different volume concentrations in sandy water. And these distributions were comparatively analyzed under the clear water and the sandy water conditions. According to the simulation results, the axial pump impeller will be damaged more easily and quickly in sandy water than in clear water. And the area more prone to damage on the axial flow impeller is predicated. The predicted vulnerable parts in an axial flow impeller are consistent with that in actual projects. This study shows that the numerical simulation results are the same as the actual situation, and it has guiding significance for the wear design of the axial flow pump. DOI: http://dx.doi.org/10.5755/j01.mech.24.3.13854