22 July 2024 in Energy Science & Engineering
The Kizilsu River Basin in China is located in the desert Gobi area with high sediment content and high hardness. After 4798h operation, the maintenance of a high‐head Francis turbine in this basin found that the guide vane was seriously worn, and even most of the top and lower skirts of the front of the guide vane were worn off. In this study, the k‐ε turbulence model, ZGB cavitation model and sediment erosion prediction model were used to simulate the solid‐liquid two‐phase flow and cavitation of guide vane. The research results show that the guide vane of a high‐head Francis turbine in a sandy river has a high sediment velocity and serious surface erosion, with the maximum erosion rate of 1.0 × 10−6 kg/(m2·s), while the area near the skirt of the guide vane is a low‐pressure area lower than the saturated steam pressure, and cavitation is very easy to occur, with the maximum vapor volume fraction of 0.9. Serious cavitation erosion occurs near the skirt of the guide vane, and the combined effect of sand erosion and cavitation erosion on the surface of the skirt of the guide vane aggravates the damage of the skirt structure. The research results provide a technical basis for the antiabrasion design of the guide mechanism of the high‐head Francis turbine and the operation and maintenance of the hydropower station in the sandy river.
1 February 2025 in Physics of Fluids
Modern power systems, energy sources, often necessitate that hydropower turbines function across a broad load range. This requirement presents significant challenges to the stable operation of turbines designed based on rated operating parameters. This study utilizes numerical simulations and experimental tests to investigate the flow characteristics, pressure pulsation, and vibration of a Francis turbine in a hydropower station within a hydro-photovoltaic hybrid system under varying load conditions. The findings indicate that with a rated head of 132 m, an intermediate head of 145 m, and a maximum head of 156.5 m, the internal flow pattern of the turbine becomes chaotic when the opening degree is between 20% and 40%. In contrast, when the opening degree ranges from 70% to 100%, the extent of eddy currents around the runner blades decreases, leading to a more stable flow pattern. Severe cavitation of the runner blades occurs at 20% opening when the water head is between 132 and 145 m. However, at a water head of 156.5 m, only minor cavitation is observed at the runner's inlet edge. As the guide vane opening increases, the primary cavitation zone shifts from the interior of the runner to the lower end of the discharge cone. Pressure pulsation and vibration tests suggest that operation should be minimized in the 55% to 70% opening range when the rated head is 132 m. To maintain efficient and stable operation of the power station unit, it is recommended that operating conditions be maintained within the 70% to 80% opening range. These findings offer a technical support and a theoretical framework for expanding the stable operation range of hydraulic turbines.
24 September 2024 in Energy Science & Engineering
In view of problems such as the narrow efficiency area, large hydraulic vibration area, pressure pulsation, and serious sediment wear of turbines at the Futang hydropower station, the technical transformation of turbine runners was carried out by modifying the blade shape and increasing the blade thickness, and a combination of numerical simulations based on shear stress transport k–ω turbulence model and tests was adopted to improve the operational stability of power station units. Calculation and testing demonstrate an enlargement of the high‐efficiency zone. Specifically, the optimal efficiency of the runner increases by 0.37%, while the rated efficiency rises by 0.19%. Significant reductions are observed in pressure pulsation within the draft tube and vaneless area decrease of approximately 50%. There is a high‐frequency pressure pulsation in the vaneless zone and the runner under low‐load conditions, and the influence of dynamic and static interference gradually weakens with the increase of opening. The draft tube is prone to eccentric vortex bands under partial working conditions, which causes the unit to be affected by low‐frequency pulsation. This optimization also leads to a notable decrease in runner blade wear, with the maximum sand and water velocity reduced from 45 to 40 m/s, resulting in a 30% reduction in sand wear. Moreover, there is a substantial enhancement in the runner's stiffness, with the thickness of the blade near the high stress area of the upper crown and lower ring increasing by over 50%, and the weight of each individual blade increasing by more than 50%. These research findings validate that modifying the runner blade effectively improves flow patterns, reduces eddy current generation, minimizes pressure pulsation, widens the high‐efficiency zone, decreases wear, and enhances the operational stability of the unit. The technical transformation method and research results of this study have important guiding significance for similar technical transformation of other power stations
1 October 2024 in Physics of Fluids
Due to the high sand content and hardness in the Kezilesu River Basin, the high-head Francis turbines operating in this basin experience significant issues of guide vane erosion. By altering the skirt structure through varying guide vane height to skirt maximum diameter ratio Δ, the anti-abrasion design of turbine guide vane can be improved. The sand-water velocity, local sediment concentration distribution, and sediment erosion at the surface of a 250 m turbine in a power station within this basin were numerically analyzed under different Δ and operating conditions. The study investigated the influence of different Δ on the wear of the turbine guide vane. The numerical calculations of sand-water flow and sediment erosion in the turbine revealed that under rated working conditions, an optimal Δ = 1.511 was obtained. The sand and water flow remained stable, with low sediment concentration near the skirt. The maximum velocity of sand and water at the skirt wall was lower compared to other Δ conditions, i.e., approximately 45 m/s, and the weighted wear area was only 1057 mm2. Under low flow conditions, an optimal Δ = 1.511 was obtained, with the sediment concentration near the skirt gradually increasing with an increase in Δ. Additionally, the maximum velocity at the skirt wall was about 60 m/s under both conditions. The ratio Δ and the erosion resistance of guide vanes initially increased and then decreased. The research results offer a technical basis for the anti-abrasion design of the guide vane in high-head Francis turbines operating in high hardness, sandy waters.
13 May 2025 in Energy Science & Engineering
To examine the sand–water flow characteristics in the distributor of the Francis‐99 hydraulic turbine, numerical simulations were conducted using the Mixture multiphase flow model, focusing on the impact of varying sand particle sizes. The findings indicate that near‐wall velocities of sand and water in the fixed and guide vanes of the Francis‐99 hydraulic turbine range from 1.5 to 3.4 m/s and from 2.1 to 11.2 m/s, respectively, with the highest values observed at the tail section. The trajectories of smaller sand particles closely followed the water flow, whereas for particle sizes of around 0.3 mm, acceleration and deceleration processes showed a noticeable lag due to inertia, leading to significant velocity fluctuations compared to smaller particles. The sediment concentration on the front side of the stay and guide vanes initially increased and then decreased along the flow direction, whereas on the back side, a gradual reduction was observed, with the peak sediment concentration occurring at the head. As the sand particle size increased, the uniformity of the sediment concentration distribution on the guide vane surface decreased. When the average sediment concentration (volume fraction) in the flow field was 0.00095, the maximum concentration on the front side of the guide vane reached 0.0025, and the region of high concentration expanded, whereas the back side showed an opposite trend. The results further demonstrate that the arrangement of fixed and guide vanes influences the sediment concentration distribution in the sand–water flow within the hydraulic guide mechanism of the Francis‐99 hydraulic turbine, leading to inconsistencies in sediment distribution patterns on adjacent guide vane surfaces.