Introduction: The FreeStyle Libre is a flash glucose monitoring (FSL-FGM) system. Compared with finger-prick based self-monitoring of blood glucose, FSL-FGM may provide benefits in terms of improved glycemic control and decreased disease burden. Methods: Prospective nationwide registry. Participants with diabetes mellitus (DM) used the FSL-FGM system for a period of 12 months. End points included changes in HbA1c, hypoglycemia, health-related quality of life (12-Item Short Form Health Surveyv2 (SF-12v2) and 3-level version of EuroQol 5D (EQ-5D-3L)), a specifically developed patient-reported outcome measures (PROMs) questionnaire, diabetes-related hospital admission rate and work absenteeism. Measurements were performed at baseline, and after 6 months and 12 months. Results: 1365 persons (55% male) were included. Mean age was 46 (16) years, 77% of participants had type 1 DM, 16% type 2 DM and 7% other forms. HbA1c decreased from 64 (95%CI 63 to 65) mmol/mol to 60 (95%CI 60 to 61) mmol/mol with a difference of −4 (95% CI −6 to 3) mmol/mol. Persons with a baseline HbA1c >70 mmol/mol had the most profound HbA1c decrease: −9 (95% CI −12 to to 5) mmol/mol. EQ-5D tariff (0.03 (95%CI 0.01 to 0.05)), EQ-VAS (4.4 (95%CI 2.1 to 6.7)) and SF-12v2 mental component score (3.3 (95%CI 2.1 to 4.4)) improved. For most, PROMs improved. Work absenteeism rate (/6 months) and diabetes-related hospital admission rate (/year) decreased significantly, from 18.5% to 7.7% and 13.7% to 2.3%, respectively. Conclusions: Real world data demonstrate that use of FSL-FGM results in improved well-being and decreased disease burden, as well as improvement of glycemic control.
Aims: Among persons with type 2 diabetes mellitus (T2DM) hypomagnesaemia has been reported in 14–48% of patients. This may be of significance given the emerging associations of hypomagnesaemia with glucometabolic disturbances and possibly even complications. We assessed the prevalence of hypomagnesaemia and its determinants, in a well-defined cohort of persons with T2DM treated in primary care. Methods: Observational cohort study among persons with T2DM treated in primary care in the Northeast of the Netherlands. Magnesium was measured using a colorimetric endpoint assay (Roche). Hypomagnesaemia was defined as a serum magnesium level <0.70 mmol/L. Pearson correlations were performed to correlate variables with serum magnesium. Next, a stepwise backward regression model was made. Results: Data of 929 persons (55% male) with a mean age of 65 (± 10) years, diabetes duration 6.5 [3.0–10.1] years, and HbA1c concentration 6.7 (± 0.7)% (50 (± 9) mmol/mol) were analysed. Serum magnesium was 0.79 (± 0.08) mmol/L. The percentage of persons with magnesium deficiency was 9.6%. Age, diabetes duration, BMI, HbA1c, use of metformin, sulfonylurea derivatives, and DPP4 inhibitors were negatively associated with magnesium concentrations. In contrast, LDL cholesterol and serum creatinine were positively associated serum magnesium. Conclusions: Hypomagnesaemia was present in 9.6% of T2DM patients treated in primary care. This percentage is remarkably lower than reported previously, possibly due to the unselected nature of our population. Concerning T2DM-related factors, only BMI, HbA1c and the use of metformin, sulfonylurea derivatives and DPP4 inhibitors correlated negatively with magnesium concentrations.
17 February 2021 in BMJ Open Diabetes Research & Care
Introduction Diabetic ketoacidosis (DKA) is a life-threatening complication of type 1 diabetes mellitus (T1DM) characterized by hyperglycemia and metabolic acidosis. Hypophosphatemia in DKA often occurs during hospital admittance for DKA. Literature on the magnitude, determinants and consequences of hypophosphatemia in DKA is scarce. Primary aim of this study was to investigate the incidence and consequences of hypophosphatemia during hospitalisation for DKA. Research design and methods Cohort study among individuals with T1DM who were admitted for DKA between 2005 and 2020 in an academic and a non-academic hospital. Multivariate regression models were performed to investigate determinants of the lowest phosphate during the treatment of DKA. Results A total of 127 episodes of DKA among 80 individuals were identified. Age at DKA presentation was 28 (22–46) years, 45% of the cases was female, diabetes duration was 13.2 (8.9–25.5) years with glycosylated hemoglobin levels of 91.9±26.2 mmol/mol. In 9% of all cases, DKA was the first presentation of T1DM. Lowest phosphate levelss reported during the treatment phase were 0.54 (0.32–0.83) mmol/L and hypophosphatemia was present in 74% (62/84). The time to lowest phosphate was 16 (8–23) hours. In multivariate analysis, baseline bicarbonate and hemoglobin at admission were significantly associated with the lowest phosphate level reported. No adverse effects of hypophosphatemia on hospital stay duration, morbidity or mortality were found, even if left untreated. Conclusions Hypophosphatemia during DKA is common and increases with severe acidosis. However, in this study it was not related to adverse outcomes. Although limitations of this retrospective study should be taken into account, the routine and repeated measurement of phosphate levels in DKA could be reconsidered, provided that possible symptoms related to hypophosphatemia are monitored.
11 August 2020 in BMJ Open Diabetes Research & Care
Introduction Accurate blood glucose measurements are important in persons with diabetes during normal daily activities (NDA), even more so during exercise. We aimed to investigate the performance of fluorescence sensor-based and glucose oxidase-based interstitial glucose measurement during (intensive) exercise and NDA. Research design and methods Prospective, observational study in 23 persons with type 1 diabetes when mountain biking for 6 days, followed by 6 days of NDA. Readings of the Eversense (fluorescence-based continuous glucose monitoring (CGM); subcutaneously implanted) and of the Free Style Libre (FSL; glucose oxidase-based flash glucose monitoring (FGM); transcutaneously placed) were compared with capillary glucose levels (Free Style Libre Precision NeoPro strip (FSLCstrip)). Results Mean average differences (MAD) and mean average relative differences (MARD) were significantly different when comparing exercise with NDA (reference FSLCstrip); Eversense MAD 25±19 vs 17±6 mg/dL (p<0.001); MARD 17±6 vs 13%±6% (p<0.01) and FSL MAD 32±17 vs 18±8 mg/dL (p<0.01); MARD 20±7 vs 12%±5% (p<0.001). When analyzing the data according to the Integrated Continuous Glucose Monitoring Approvals (class II–510(K) guidelines), the overall performance of interstitial glucose readings within 20% of the FSLCstrip during exercise compared with NDA was 69% vs 81% for the Eversense and 59% vs 83% for the FSL, respectively. Within 15% of the FSLCstrip was 59% vs 70% for the Eversense and 46% vs 71% for the FSL. Conclusions During exercise, both fluorescence and glucose oxidase-based interstitial glucose measurements (using Eversense and FSL sensors) were less accurate compared with measurements during NDA. Even when acknowledging the beneficial effects of CGM or FGM, users should be aware of the risk of diminished accuracy of interstitial glucose readings during (intensive) exercise.