Introduction Accurate blood glucose measurements are important in persons with diabetes during normal daily activities (NDA), even more so during exercise. We aimed to investigate the performance of fluorescence sensor-based and glucose oxidase-based interstitial glucose measurement during (intensive) exercise and NDA. Research design and methods Prospective, observational study in 23 persons with type 1 diabetes when mountain biking for 6 days, followed by 6 days of NDA. Readings of the Eversense (fluorescence-based continuous glucose monitoring (CGM); subcutaneously implanted) and of the Free Style Libre (FSL; glucose oxidase-based flash glucose monitoring (FGM); transcutaneously placed) were compared with capillary glucose levels (Free Style Libre Precision NeoPro strip (FSLCstrip)). Results Mean average differences (MAD) and mean average relative differences (MARD) were significantly different when comparing exercise with NDA (reference FSLCstrip); Eversense MAD 25±19 vs 17±6 mg/dL (p<0.001); MARD 17±6 vs 13%±6% (p<0.01) and FSL MAD 32±17 vs 18±8 mg/dL (p<0.01); MARD 20±7 vs 12%±5% (p<0.001). When analyzing the data according to the Integrated Continuous Glucose Monitoring Approvals (class II–510(K) guidelines), the overall performance of interstitial glucose readings within 20% of the FSLCstrip during exercise compared with NDA was 69% vs 81% for the Eversense and 59% vs 83% for the FSL, respectively. Within 15% of the FSLCstrip was 59% vs 70% for the Eversense and 46% vs 71% for the FSL. Conclusions During exercise, both fluorescence and glucose oxidase-based interstitial glucose measurements (using Eversense and FSL sensors) were less accurate compared with measurements during NDA. Even when acknowledging the beneficial effects of CGM or FGM, users should be aware of the risk of diminished accuracy of interstitial glucose readings during (intensive) exercise.
14 September 2021 in BMJ Open Diabetes Research & Care
Introduction: The FreeStyle Libre (FSL) is a flash glucose monitoring (FGM) system. The Flash Monitor Register in the Netherlands (FLARE-NL-4) study previously demonstrated the positive effects of FSL-FGM use during 1 year on glycemic control, quality of life and disease burden among persons with diabetes mellitus (DM). The present follow-up study assesses the effects of FSL-FGM after 2 years. Research design and methods: Patients included in the FLARE-NL-4 study who continued FSL-FGM during the 1-year study period were invited to participate (n=687). Data were collected using questionnaires (the 12-Item Short Form Health Survey version 2 (SF-12v2) and the EuroQol 5-Dimension 3-Level (EQ-5D-3L) for quality of life), including self-reported hemoglobin A1c (HbA1c). Results: A total of 342 patients agreed to participate: mean age 48.0 (±15.6) years, 52% men and 79.5% with type 1 DM. HbA1c decreased from 60.7 (95% CI 59.1 to 62.3) mmol/mol before use of FSL-FGM to 57.3 (95% CI 55.8 to 58.8) mmol/mol after 1 year and 57.8 (95% CI 56.0 to 59.5) mmol/mol after 2 years. At the end of the 2-year follow-up period, 260 (76%) persons were still using the FSL-FGM and 82 (24%) had stopped. The main reason for stopping FSL-FGM was financial constraints (55%). Concerning the whole 2-year period, there was a significant decrease in HbA1c among persons who continued use of FSL-FGM (−3.5 mmol/mol, 95% CI −6.4 to –0.7), while HbA1c was unaltered compared with baseline among persons who stopped FSL-FGM (−2.4 mmol/mol, 95% CI −7.5 to 2.7): difference between groups 2.2 (95% CI −1.3 to 5.8) mmol/mol. After 2 years, persons who continued use of FSL-FGM had higher SF-12 mental component score and higher EQ-5D Dutch tariff score and felt less often anxious or depressed compared with persons who discontinued FSL-FGM. Conclusions: Although the considerable number of non-responders limits generalizability, this study suggests that persons who continue to use FSL-FGM for 2 years may experience sustained improvement in glycemic control and quality of life.
Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose due to different metal artefacts. The O-MAR algorithm deploys an iterative loop where the metal sinogram is identified, extracted, and subsequently serves as a mask to correct the measured sinogram. Main goal of this study is to quantify the ability of the O-MAR technique to correct deviation in medullary bone attenuation caused by streak artefacts from the large-head MoM THA embedded in a phantom. Secondary goal is to evaluate the influence of O-MAR on CNR. The phantom was designed as a Perspex box (PMMA) containing water and a supplementary MOM THA surrounded by Perspex columns comprising calibrated calcium pellets. Each column contains 200 mg of hydroxyapatite/calcium carbonate to simulate healthy bone tissue. Scans were obtained with and without a MoM THA at different dose levels. Different reconstructions were made with filter A, iDose4 level 5 and with and without O-MAR. The scans without the prosthesis were used as the baseline. Information about the attenuation in Hounsfield units, image noise in standard deviation within the ROI’s were extracted and the CNR was calculated. Pellet L0 and R0 (proximal of the MoM THA) were defined as reference, lacking any disturbance by metal artefacts; L5, L6 and L8 were respectively visually categorized as ‘light’ ‘medium’ and ‘heavy disturbance’. Significant improvements in attenuation deviation caused by metal artefact were 43, 68 and 32 %, for respectively pellet L5, L6 and L8 (p < 0.001). Significant CNR improvements were present for L5 and L6 and were respectively 72 and 52 % (p < 0.001). O-MAR showed no improvement on CNR for L8. This phantom study significantly increases image quality by the use of O-MAR in the presence of metal artefacts by significantly reducing metal artefacts subsequently and increasing CNR on a 64 slice CT system in light and medium disturbance of the image.
To evaluate the incidence and characteristics of brain lesions in moderate-late preterm (MLPT) infants, born at 32-36 weeks' gestation using cranial ultrasound (cUS) and magnetic resonance imaging (MRI). Prospective cohort study carried out at Isala Women and Children's Hospital between August 2017 and November 2019. cUS was performed at postnatal day 3-4 (early-cUS), before discharge and repeated at term equivalent age (TEA) in MLPT infants born between 32+0 and 35+6 weeks' gestation. At TEA, MRI was also performed. Several brain lesions were assessed e.g. hemorrhages, white matter and deep gray matter injury. Brain maturation was visually evaluated. Lesions were classified as mild or moderate-severe. Incidences and confidence intervals were calculated. 166 MLPT infants were included of whom 127 underwent MRI. One or more mild lesions were present in 119/166 (71.7 %) and moderate-severe lesions in 6/166 (3.6 %) infants on cUS and/or MRI. The most frequent lesions were signs suggestive of white matter injury: inhomogeneous echogenicity in 50/164 infants (30.5 %) at early-cUS, in 12/148 infants (8.1 %) at TEA-cUS and diffuse white matter signal changes (MRI) in 27/127 (23.5 %) infants. Cerebellar hemorrhage (MRI) was observed in 16/127 infants (12.6 %). Delayed maturation (MRI) was seen in 17/117 (13.4 %) infants. Small hemorrhages and punctate white matter lesions were more frequently detected on MRI than on cUS. In MLPT infants mild brain lesions were frequently encountered, especially signs suggestive of white matter injury and small hemorrhages. Moderate-severe lesions were less frequently seen.
Introduction: Chronic cough affects ∼10% of the population and adversely impacts quality of life. This retrospective observational cohort study aimed to identify the demographics, clinical characteristics and quality of life of the chronic cough population in a Dutch chronic cough clinic, at baseline and following treatment at 6 months. Patients were categorised based on the underlying phenotype and response to treatment.Methods: Retrospective data on 2397 patients who were diagnosed according to standard guidelines of the American College of Chest Physicians were analysed. Quality of life was capturedviathe Leicester Cough Questionnaire, the Cough Numeric Rating Scale and the Hospital Anxiety and Depression Scale.Results: Mean patient age was 59 years; 62.5% of the patients were female; and 69.1% had at least one underlying phenotype associated with chronic cough. Of the latter, 52.1% had bronchial hyperresponsiveness/airflow limitation, 33.3% had airway reflux and 20.1% had upper airway cough syndrome. 46% of patients with a phenotype, and 51% without, experienced no improvement in their quality of life or still had significant cough remaining after 6 months. Of patients with available quality-of-life data, 37.5% were categorised as having refractory chronic cough, and 9.5% were categorised as unexplained chronic cough.Discussion: This study highlights the poor quality-of-life outcomes in patients with chronic cough, despite interventions to treat underlying conditions, and indicates a need to manage chronic cough irrespective of phenotype.