A time-dependent 3D numerical model considering anode evaporation is developed for the high current vacuum arc (VA) under a realistic spatial magnetic field. The simulation work contains steady state 3D numerical simulation of high current VA considering anode evaporation at nine discrete moments of first half wave of 50 Hz AC current, transient numerical simulation of anode activity, and realistic spatial magnetic field calculation of commercial cup-shaped electrodes. In the simulation, contact opening and arc diffusion processes are also considered. Due to the effect of electrode slots, the simulation results of magnetic field and temperature of anode plate exhibit six leaves shape (SLS). During 6–8 ms, the strong evaporation of anode surface seriously influence the parameter distributions of VA. Ions emitted from anode penetrate into arc column and the axial velocity distribution on the anode side exhibits SLS. The ions emitted from anode surface have the same temperature with anode surface, which cool the arc plasma and lead to a relative low temperature area formed. The seriously evaporation of anode leads to the accumulation of ions near the anode, and then the current density is more uniform.
9 February 2022 in Journal of Magnetism and Magnetic Materials
The inter-contact region of vacuum circuit breakers is filled with residual plasma at the moment when the current is zero after the burning of metal vapor arc. The residual plasma forms an ion sheath in front of the post-arc cathode. The sheath then expands towards the post-arc anode under the influence of a transient recovery voltage. In this study, a one-dimensional particle-in-cell model is developed to investigate the post-arc sheath expansion. The influence of ion and electron temperatures on the decrease in local plasma density at the post-arc cathode side and post-arc anode side is discussed. When the decay in the local plasma density develops from the cathode and anode sides into the high-density region and merges, the overall plasma density in the inter-contact region begins to decrease. Meanwhile, the ion sheath begins to expand faster. Furthermore, the theory of ion rarefaction wave only explains quantitatively the decrease in the overall plasma density at relatively low ion temperatures. With the increase of ion temperature to certain extent, another possible reason for the decrease in the overall plasma density is proposed and results from the more active thermal diffusion of plasma.
The residual plasma in the inter-contact region of a vacuum circuit breaker moves towards the post-arc cathode at current zero, because the residual plasma mainly comes from the cathode spots during the arc burning process. In the most previous theoretical researches on the post-arc sheath expansion process of vacuum circuit breakers, only the thermal motion of residual plasma was taken into consideration. Alternately, the residual plasma was even assumed to be static at the moment of current zero in some simplified models. However, the influence of residual plasma drift velocity at current zero on the post-arc sheath expansion process was rarely investigated. In this paper, this effect is investigated by a one-dimensional particle-in-cell model. Simulation results indicate that the sheath expands slower with higher residual plasma drift velocity in the initial sheath expansion stage. However, with the increase of residual plasma drift velocity, the overall plasma density in the inter-contact region decreases faster, and the sheath expansion velocity increases earlier. Consequently, as a whole, it needs shorter time to expel the residual plasma from the inter-contact region. Furthermore, if the residual plasma drift velocity is high enough, the sheath expansion process ceases before it develops to the post-arc anode. Besides, the influence of the collisions between charges and neutrals is investigated as well in terms of the density of metal vapor. It shows that the residual plasma drift velocity takes remarkable effect only if the density of the metal vapor is relatively low, which corresponds to the circumstance of low-current interruptions.
4 August 2023 in Journal of Physics D: Applied Physics
In this paper, we introduce a novel design of a metamaterial unit cell absorber, which is based on a metal/insulator/metal sandwich structure. The design is subjected to comprehensive finite element method computational analysis to ensure accurate and reliable results. The proposed metamaterial sandwich structure demonstrates exceptional absorption performance, achieving a nearly perfect absorption rate of 99.996% at the resonance infrared frequency of 39.8 THz. To provide a detailed theoretical explanation of nearly perfect absorption, we employ the effective medium theory, impedance matching, and field distribution analysis. Additionally, we have optimized the structural parameters of the sensor to maximize its absorption peak. This includes optimizing the thickness of the gold (Au) layer (from 0.03 to 0.28 μm), the distance between the L shape corners (from 0.60 to 0.90 μm), and the thickness of SiC dielectric spacer (from 0.20 to 0.45 μm). Furthermore, we showcase the remarkable sensitivity of the proposed metamaterial unit cell in detecting subtle changes in the refractive index through the implementation of a sensing medium setup in our model. Remarkably, we achieve a frequency shift sensitivity of 3.74 THz/RIU, along with a quality factor of 10.33, for a wide range of refractive indices (1.0–2.0). Moreover, for cancer detection, we attain a sensitivity of 3.5 THz/RIU. These findings highlight the exceptional performance of our approach in accurately detecting changes in refractive index, making it a promising candidate for various sensing applications. The novelty of our work lies in the design of a metamaterial unit cell structure. This configuration exhibits several noteworthy features, including wide incident angle ( ) coverage up to 60°, polarization insensitivity, exceptional frequency shift sensitivity, high absorption peaks across a wide range of refractive indices, and the ability to distinguish cancer cells from healthy ones.