Physicians performing cardiac angiography are exposed to scattered radiation originating from the patient, and visualizing scattered radiation sources could help optimize radiation protection strategies. In this study, an existing scattered radiation source visualization system comprising a high-sensitivity CMOS camera, thallium-activated cesium iodide scintillator, and pinhole collimator was extended to incorporate a depth camera and employed to visualize scattered radiation sources in three dimensions under conditions simulating clinical cardiac angiography. Scattered radiation source images were captured using a patient phantom under multiple irradiation directions of a biplane angiography system, and changes in the images and dose rate reaching the system were evaluated with and without radiation protection equipment and for various ceiling-mounted radiation shielding positions. The scattered radiation source was visualized on the patient phantom surface for a 5-s exposure in three-dimensional images and was observed around the X-ray tube in one direction. Radiation protection equipment reduced both the scattered radiation source intensity and dose rate. The greatest reduction occurred when the ceiling-mounted radiation shielding was positioned near the physician. Irradiation at caudal angles caused the highest increase in scattered radiation source intensity and dose rate. These findings suggest that this system can support the optimization of radiation protection practices and education.
This study presents the development and evaluation of an Augmented Reality (AR)-based training system aimed at improving patient setup accuracy in radiation therapy. Leveraging Microsoft HoloLens 2, the system provides an immersive environment for medical staff to enhance their understanding of patient setup procedures. High-resolution 3D anatomical models were reconstructed from CT scans using 3D Slicer, while Luma AI was employed to rapidly capture complete body surface models. Due to limitations in each method—such as missing extremities or back surfaces—Blender was used to merge the models, improving completeness and anatomical fidelity. The AR application was developed in Unity, employing spatial anchors and 125 × 125 mm2 QR code markers to stabilize and align virtual models in real space. System accuracy testing demonstrated that QR code tracking achieved millimeter-level variation, with an expanded uncertainty of ±2.74 mm. Training trials for setup showed larger deviations in the X (left–right), Y (up-down), and Z (front-back) axes at the centimeter scale. This meant that we were able to quantify the user’s patient setup skills. While QR code positioning was relatively stable, manual placement of markers and the absence of real-time verification contributed to these errors. The system offers a radiation-free and interactive platform for training, enhancing spatial awareness and procedural skills. Future work will focus on improving tracking stability, optimizing the workflow, and integrating real-time feedback to move toward clinical applicability.