This paper presents a nondestructive test method to evaluate the residual bending strength of corroded reinforced concrete beam by analyzing the self-magnetic flux leakage (SMFL) signals. The automatic scanning device was equipped with a micromagnetic sensor and sensor-based experimental details were introduced. Next, the theoretical formula of the normal component HS(z) of the SMFL signal that originated from the corroded region was derived based on the magnetic dipole model and the experimental results were discussed. The results indicate that the experimental data of HS(z) are consistent with the theoretical calculations, both location and extent of the steel bars corrosion can be qualitatively determined by using HS(z). The gradient K of HS(z) is approximately linearly related to the loss rate, S, of the bending strength, which can be used to evaluate the residual bending strength of the corroded reinforced concrete beam. This work lays the foundation for evaluating the residual bending strength of corroded reinforced concrete beams using the SMFL signal; the micromagnetic sensor is further applied to the civil engineering.
Corrosion is among the most critical factors leading to the failure of reinforced concrete (RC) structures. Less work has been devoted to nondestructive tests (NDT) to detect the corrosion degree of steel bars. The corrosion degree was investigated in this paper using an NDT method based on self-magnetic flux leakage (SMFL). First, a mathematic model based on magnetic dipole model was settled to simulate the SMFL of a V-shaped defect caused by corrosion. A custom 3-axis scanning device equipped with a magnetometer was used to scan the SMFL field of the 40 corroded steel bars. Experimental data obtained by scanning the 40 steel bars showed that the BZ curve of SMFL was consistent with the theoretical model analysis. Inspired by the qualitative analysis of the results, an index “K” based on a large number of experimental data was established to characterize the corrosion degree of steel bars. The experimental index “K” was linearly related to the corrosion degree α of steel bars. This paper provides a feasible approach for the corrosion degree NDT, which is not affected by the magnetization history and the initial magnetization state of steel bars.
1 January 2024 in Structural Control and Health Monitoring
The reliability of corroded reinforced concrete (RC) structures relies on the accurate minimum cross‐sectional area of corroded rebar. In this study, the accurate morphologies and self‐magnetic flux leakage (SMFL) field strengths of twenty‐eight non‐uniformly corroded rebars were obtained using 3D structural light scanning and micromagnetic detection technologies, based on which three indices of the SMFL field variation ratio dH, the corrosion non‐uniformity degree dSn, and the cross‐sectional area ratio K0.25 are proposed. The statistical results show that the probability densities of dSn and K0.25 obey the Weibull distribution and Gamma distribution at the 95% confidence level, respectively, and their distribution parameters are linearly or inversely proportional to dH. The probability density distribution of the minimum cross‐sectional area of corroded rebar can be determined using indices dSn and K0.25, based on which a feasible SMFL‐based reliability assessment method of corroded RC structures is proposed. The case study of a real specific corroded RC beam shows that the reliability assessment error of the SMFL‐based method is only 1.2%, which is much lower than the 20.7% error of the existing method. This SMFL‐based method provides a novel idea that can automatically and accurately assess the effect of rebars’ corrosion non‐uniformity on the reliability of specific in‐serviceRC structures.