This paper presents a spectrum analysis of the terminal voltage after supply disconnection. This voltage is induced only by the rotor flux and does not depend on the mechanical load, the voltage supply time harmonics, etc... The diagnosis technique is based on monitoring the amplitude of harmonics components in the frequency domain using both FFT and MUSIC methods. The experimental results show the presence of harmonics of order 6mplusmn1, m=1,2,3... for healthy and faulty machine. When there is a rotor bar fault, the amplitude of these harmonics grows. The spectral analysis shows that MUSIC method is more reliable than the FFT technique, and the induced voltage technique is independent on the load level.
This paper proposes a 2D semi-analytical model based on the subdomain method for the performance analysis of a brushless doubly fed reluctance machine (BDFRM) with a salient pole rotor. In particular, assuming an infinite magnetic permeability of the iron core and assuming a smooth stator, the field calculation region is divided into two solution subdomains, i.e., the rotor slot and air-gap. The magnetic vector potential in each subdomain is obtained by solving the governing PDE by the separation of variables method and employing the boundary conditions between adjacent interfaces. Moreover, based on the stored magnetic energy in the air-gap, the calculation of the three-phase windings’ self and mutual inductances is presented. Through a case study involving a 6/2 pole BDFRM, the accuracy of the developed subdomain model is confirmed by comparing its analytically predicted results with those obtained from two-dimensional finite element method (FEM) simulations.