Jiafeng Zhu

Dr. Jiafeng Zhu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2023 in Processes
Verified
Journal Article
Open access
PDF file
KEPENG ZHANGKEPENG ZHANG
KEPENG ZHANG
Dazhuan WuDazhuan Wu
Dazhuan Wu
HWHuan Wang
Huan Wang
JLJianjun Li
Jianjun Li
ZFZhongbo Feng
Zhongbo Feng
ZLZhounian Lai
Zhounian Lai
Unsmooth reversing is one of the most common faults in the four-way reversing valve of the air conditioning system, and the airflow in the valve chamber and the shape of the slider of the reversing valve are the main factors in unsmooth reversing. In order to study the influence of the airflow in the chamber and the slider shape on the reversing process, the fluid flow in the valve chamber of a four-way reversing valve is obtained using computational fluid dynamics (CFD) simulations, and the influence of the slider structure on slider thrust and resistance of the four-way reversing valve is analyzed. Four-way reversing valves with no-cutting, straight-cutting and arc-cutting sliders are employed to evaluate the reversing characteristics. A pressure measuring device for a four-way reversing valve chamber is designed, which is performed to test the chamber pressure of three different types of sliders of four-way reversing valves. The maximum error of experimental tests and simulations is within 5% of engineering tolerance, so as to verify the reliability of numerical simulation. The resistance-to-thrust ratio of the slider is raised to evaluate the performance of the reversing, which can guide the design of the valve and slider. The results indicate that the chamber pressure and resistance-thrust ratio with the cutting slider are reduced, which is beneficial to the reversing of the four-way reversing valve. Compared with the straight-cutting structure, the arc-cutting slider four-way reversing valve has a more stable reversing process and better comprehensive reversing performance. Results demonstrate that both the straight-cutting structure and arc-cutting structure of the slider can improve the process performance but the arc-cutting slider is better.

21 July 2023 in Processes
Verified
Journal Article
Open access
PDF file
KEPENG ZHANGKEPENG ZHANG
KEPENG ZHANG
Dazhuan WuDazhuan Wu
Dazhuan Wu
YYYadong Yuan
Yadong Yuan
JZJiafeng Zhu
Jiafeng Zhu
ZFZhongbo Feng
Zhongbo Feng
YXYunjun Xiong
Yunjun Xiong
In order to improve the low efficiency and malfunction caused by the FWRV (four-way reversing valve) when the working mode of the heat pump air conditioning system changes in refrigeration and heating, it is of great significance to study the structure of the FWRV. In this paper, the control equation of the sliding block movement process is constructed to simulate the reversing process of the FWRV in fluid mechanics, and a detailed study is carried out from the sliding block speed, sliding block acceleration, sliding block force, refrigerant leakage, and other aspects. Some studies indicate that structural improvement in the slider could greatly enhance the working performance of the FWRV. Increasing the height of the slider not only improves the pressure relief ability of the FWRV and prevents the slider from being damaged by high-pressure gas impact but also reduces the leakage of refrigerant during the directional process; when reducing the length of the slider, although it improves the pressure relief capacity of the FWRV, it also increases the amount of refrigerant leakage. The research results provide a theoretical basis and direction for designers to improve the capability of the FWRV.

14 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
KEPENG ZHANGKEPENG ZHANG
KEPENG ZHANG
Dazhuan WuDazhuan Wu
Dazhuan Wu
YYYa-Dong Yuan
Ya-Dong Yuan
JZJiafeng Zhu
Jiafeng Zhu
ZFZhong-Bo Feng
Zhong-Bo Feng
YXYun-Jun Xiong
Yun-Jun Xiong
The four-way reversing valve is a key component determining whether a heat pump air conditioning system can work. Studying the four-way reversing valve is of great significance for improving the performance of the heat pump air conditioning system. In this paper, the control equation of the sliding block movement process is constructed to simulate the reversing process of the four-way reversing valve in fluid mechanics, and a detailed study is carried out from the sliding block speed, sliding block acceleration, sliding block force, refrigerant leakage, and other aspects. Research has shown that optimizing the structure of the slider can greatly improve the working performance of the four-way reversing valve. Increasing the height of the slider not only improves the pressure relief ability of the four-way reversing valve and prevents the slider from being damaged by high-pressure gas impact, but also reduces the leakage of refrigerant during the directional process; When reducing the length of the slider, although it will improve the pressure relief capacity of the four-way reversing valve, it also increases the amount of refrigerant leakage. The research results provide a theoretical basis and improvement direction for designers to improve the performance of four-way reversing valves.