Scott Banks

Prof. Scott Banks

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2011 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
TBThor F. Besier
Thor F. Besier
DLDavid Lloyd
David Lloyd
SDScott L. Delp
Scott L. Delp
SBScott Banks
Scott Banks
DDDarryl D'lima
Darryl D'lima
Impairment of the human neuromusculoskeletal system can lead to significant mobility limitations and decreased quality of life. Computational models that accurately represent the musculoskeletal systems of individual patients could be used to explore different treatment options and optimize clinical outcome. The most significant barrier to model‐based treatment design is validation of model‐based estimates of in vivo contact and muscle forces. This paper introduces an annual “Grand Challenge Competition to Predict In Vivo Knee Loads” based on a series of comprehensive publicly available in vivo data sets for evaluating musculoskeletal model predictions of contact and muscle forces in the knee. The data sets come from patients implanted with force‐measuring tibial prostheses. Following a historical review of musculoskeletal modeling methods used for estimating knee muscle and contact forces, we describe the first two data sets used for the first two competitions and summarize four subsequent data sets to be used for future competitions. These data sets include tibial contact force, video motion, ground reaction, muscle EMG, muscle strength, static and dynamic imaging, and implant geometry data. Competition participants create musculoskeletal models to predict tibial contact forces without having access to the corresponding in vivo measurements. These blinded predictions provide an unbiased evaluation of the capabilities and limitations of musculoskeletal modeling methods. The paper concludes with a discussion of how these unique data sets can be used by the musculoskeletal modeling research community to improve the estimation of in vivo muscle and contact forces and ultimately to help make musculoskeletal models clinically useful. © 2011 Orthopaedic Research Society. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 30:503–513, 2012

1 June 1996 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SBScott Banks
Scott Banks
WHW.A. Hodge
W.A. Hodge
A simple extension of a previously reported object recognition technique has been used to implement a six-degree-of-freedom position/orientation estimator for the measurement of knee replacement motion from two-dimensional (2-D) fluoroscopic images. Computer modeling studies and controlled mechanical tests were performed to assess the accuracy of the technique. The results indicate that knee rotations can be measured with an accuracy of approximately one degree and that sagittal plane translations can be measured with an accuracy of approximately 0.5 mm. The measurement technique is uniquely well suited for performing dynamic kinematic measurements on individuals with knee replacements, and for performing comparative studies among subjects with different designs of knee replacements.

7 March 2007 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
DZDong Zhao
Dong Zhao
SBScott Banks
Scott Banks
KMKim H. Mitchell
Kim H. Mitchell
DDDarryl D'lima
Darryl D'lima
CCClifford W. Colwell
Clifford W. Colwell
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. This study uses in vivo data collected from a single subject with an instrumented knee implant to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe‐out) with simultaneous collection of instrumented implant, video motion, and ground reaction data. For each trial, the knee adduction torque was measured externally while the total axial force applied to the tibial insert was measured internally. Based on data collected from the same subject performing treadmill gait under fluoroscopic motion analysis, a regression equation was developed to calculate medial contact force from the implant load cell measurements. Correlation analyses were performed for the stance phase and entire gait cycle to quantify the relationship between the knee adduction torque and both the medial contact force and the medial to total contact force ratio. When the entire gait cycle was analyzed, R2 for medial contact force was 0.77 when all gait trials were analyzed together and between 0.69 and 0.93 when each gait trial was analyzed separately (p < 0.001 in all cases). For medial to total force ratio, R2 was 0.69 for all trials together and between 0.54 and 0.90 for each trial separately (p < 0.001 in all cases). When only the stance phase was analyzed, R2 values were slightly lower. These results support the hypothesis that the knee adduction torque is highly correlated with medial compartment contact force and medial to total force ratio during gait. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25: 789–797, 2007

1 January 2005 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
MHMelinda Harman
Melinda Harman
MFMark A Frankle
Mark A Frankle
MVMatt Vasey
Matt Vasey
SBScott Banks
Scott Banks

1 November 2013 in Journal of Biomechanics
Verified
Journal Article
Open access
GPGerus Pauline
Gerus Pauline
Massimo SartoriMassimo Sartori
Massimo Sartori
TBThor F. Besier
Thor F. Besier
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
SDScott L. Delp
Scott L. Delp
DLDavid Lloyd
David Lloyd
Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the prediction of tibiofemoral contact forces using a calibrated EMG-driven neuromusculoskeletal model of the knee. One participant fitted with an instrumented total knee replacement walked at a self-selected speed while medial and lateral tibiofemoral contact forces, ground reaction forces, whole-body kinematics, and lower-limb muscle activity were simultaneously measured. The combination of generic and subject-specific knee joint geometry and kinematics resulted in four different OpenSim models used to estimate muscle-tendon lengths and moment arms. The subject-specific geometric model was created from CT scans and the subject-specific knee joint kinematics representing the translation of the tibia relative to the femur was obtained from fluoroscopy. The EMG-driven model was calibrated using one walking trial, but with three different cost functions that tracked the knee flexion/extension moments with and without constraint over the estimated joint contact forces. The calibrated models then predicted the medial and lateral tibiofemoral contact forces for five other different walking trials. The use of subject-specific models with minimization of the peak tibiofemoral contact forces improved the accuracy of medial contact forces by 47% and lateral contact forces by 7%, respectively compared with the use of generic musculoskeletal model.

1 April 1997 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
SBScott Banks
Scott Banks
GMGeorge D. Markovich
George D. Markovich
WHW.Andrew Hodge
W.Andrew Hodge