Cuong Do

Dr. Cuong Do

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
KLKhiem H. Le
Khiem H. Le
HPHieu H. Pham
Hieu H. Pham
TNThao B.T. Nguyen
Thao B.T. Nguyen
TNTu A. Nguyen
Tu A. Nguyen
TTTien N. Thanh
Tien N. Thanh
CDCuong Do
Cuong Do

2 April 2024 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
LLLinh Thi Phuong Le
Linh Thi Phuong Le
ANAnh Hoang Quan Nguyen
Anh Hoang Quan Nguyen
LPLe Minh Tu Phan
Le Minh Tu Phan
HNHien Thi Thanh Ngo
Hien Thi Thanh Ngo
XWXing Wang
Xing Wang
CDCuong Do
Cuong Do

14 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CDCuong Do
Cuong Do
ASASHWIN A. SESHIA
ASHWIN A. SESHIA
Temperature variations are one of the most crucial factors that need to be compensated for in MEMS sensors. Many traditional methodologies require an additional circuit to compensate for temperature. This work describes a new active temperature compensation method for MEMS capacitive strain sensors without additional circuits. The proposed method is based on a complement 2-D capacitive structure design. It consumes zero-power, which is essential toward the realization of a low-power temperature-compensated sensor in battery-powered or energy-harvesting applications. The gauge factor of the developed MEMS capacitive strain sensor is 7. The best result showing a capacitance variation of 1 ppm/oC compared with 13 ppm/oC on conventional design.

4 November 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TNThao Nguyen
Thao Nguyen
HPHieu H. Pham
Hieu H. Pham
KLKhiem H. Le
Khiem H. Le
ANAnh-Tu Nguyen
Anh-Tu Nguyen
TTTien Thanh
Tien Thanh
CDCuong Do
Cuong Do
The COVID-19 pandemic has exposed the vulnerability of healthcare services worldwide, raising the need to develop novel tools to provide rapid and cost-effective screening and diagnosis. Clinical reports indicated that COVID-19 infection may cause cardiac injury, and electrocardiograms (ECG) may serve as a diagnostic biomarker for COVID-19. This study aims to utilize ECG signals to detect COVID-19 automatically. We propose a novel method to extract ECG signals from ECG paper records, which are then fed into one-dimensional convolution neural network (1D-CNN) to learn and diagnose the disease. To evaluate the quality of digitized signals, R peaks in the paper-based ECG images are labeled. Afterward, RR intervals calculated from each image are compared to RR intervals of the corresponding digitized signal. Experiments on the COVID-19 ECG images dataset demonstrate that the proposed digitization method is able to capture correctly the original signals, with a mean absolute error of 28.11 ms. The 1D-CNN model (SEResNet18), which is trained on the digitized ECG signals, allows to identify between individuals with COVID-19 and other subjects accurately, with classification accuracies of 98.42% and 98.50% for classifying COVID-19 vs. Normal and COVID-19 vs. other classes, respectively. Furthermore, the proposed method also achieves a high-level of performance for the multi-classification task. Our findings indicate that a deep learning system trained on digitized ECG signals can serve as a potential tool for diagnosing COVID-19.

26 September 2025 in IEEE Transactions on Neural Networks and Learning Systems
Verified
Journal Article
Closed access
KWKOK-SENG WONG
KOK-SENG WONG
DNDuc-Manh Nguyen
Duc-Manh Nguyen
KLKhiem Le
Khiem Le
LHLong Ho
Long Ho
CDCuong Do
Cuong Do
DPDanh Le Phuoc
Danh Le Phuoc
Nowadays, billions of phones, internet-of-things (IoT), and edge devices around the world generate data continuously, enabling many machine-learning (ML)-based products and applications. However, due to increasing privacy concerns and regulations, these data tend to reside on devices (clients) instead of being centralized for performing traditional ML model training. Federated learning (FL) is a distributed approach in which a single server and multiple clients collaboratively build an ML model without moving data away from clients. Whereas existing studies on FL have their own experimental evaluations, most experiments were conducted using a simulation setting or a small-scale testbed. This might limit the understanding of FL implementation in realistic environments. In this empirical study, we systematically conduct extensive experiments on a large network of IoT and edge devices (called IoT–Edge devices) to present FL real-world characteristics, including learning performance and operation (computation and communication) costs. Moreover, we mainly concentrate on heterogeneous scenarios, which is the most challenging issue of FL. By investigating the feasibility of on-device implementation, our study provides valuable insights for researchers and practitioners, promoting the practicality of FL and assisting in improving the current design of real FL systems.

7 May 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HNHieu X. Nguyen
Hieu X. Nguyen
DNDuong V. Nguyen
Duong V. Nguyen
HPHieu H. Pham
Hieu H. Pham
CDCuong Do
Cuong Do
Sleep apnea (SA) is a significant respiratory condition that poses a major global health challenge. Deep Learning (DL) has emerged as an efficient tool for the classification problem in electrocardiogram (ECG)-based SA diagnoses. Despite these advancements, most common conventional feature extractions derived from ECG signals in DL, such as R-peaks and RR intervals, may fail to capture crucial information encompassed within the complete ECG segments. In this study, we propose an innovative approach to address this diagnostic gap by delving deeper into the comprehensive segments of the ECG signal. The proposed methodology draws inspiration from Matrix Profile algorithms, which generate an Euclidean distance profile from fixed-length signal subsequences. From this, we derived the Min Distance Profile (MinDP), Max Distance Profile (MaxDP), and Mean Distance Profile (MeanDP) based on the minimum, maximum, and mean of the profile distances, respectively. To validate the effectiveness of our approach, we use the modified LeNet-5 architecture as the primary CNN model, along with two existing lightweight models, BAFNet and SE-MSCNN. Our experiment results on the PhysioNet Apnea-ECG dataset (70 overnight recordings), and the UCDDB dataset (25 overnight recordings) revealed that our new feature extraction method achieved per-segment accuracies of up to 92.11% and 81.25%, respectively. Moreover, using the PhysioNet data, we achieved a per-recording accuracy of 100% and yielded the highest correlation of 0.989 compared to state-of-the-art methods. By introducing a new feature extraction method based on distance relationships, we enhanced the performance of certain lightweight models in DL, showing potential for home sleep apnea test (HSAT) and SA detection in IoT devices. The source code for this work is made publicly available in GitHub: https://github.com/vinuni-vishc/MPCNN-Sleep-Apnea.