Weiwei Zhang

Dr. Weiwei Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZXZhikai Xing
Zhikai Xing
YHYigang He
Yigang He
WZWeiwei Zhang
Weiwei Zhang
With the development of the processing capacity of the embedded chip, it is possible to implement a machine learning algorithm in the embedded system. To achieve the fault status without poor portability, tricky threshold selection and complex rulemaking, this paper proposes a multi-modal deep residual filter network for online multiple open-switch fault diagnosis of T-type three-level inverter. It contains low-rank matrix fusion (LMF), deep residual filter network (DRFN), and cross transformer mechanism. The LMF fuses the voltage signal and the current signal for obtaining the unified representation. And then, the DRFN filters noise adaptively and extracts information effectively. Finally, the cross-transformer mechanism output the fault state of the T-type three-level inverter. The data sets consist of the dc-link voltage and load side current of the inverter control system. The data time window is selected as 20 ms. Through the real-time calculation of online monitored data, the experimental results show the effectiveness of the proposed fault diagnosis approach. Moreover, the accuracy of fault diagnosis obtains 99.18% and the average open-circuit fault diagnosis time is 21 ms.

16 February 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WZWeiwei Zhang
Weiwei Zhang
YHYigang He
Yigang He
The open-circuit (OC) faults for T-type three-level inverters often share similar distorted output features, which are usually distinguished by adopting invasive methods. The purpose of this article is to locate the OC fault by rebuilding the established phase voltage model according to the hypothesis method. Based on the vector decomposition principle and voltage-second balancing theory, the output phase voltage model is established considering neutral point voltage unbalance and time-offset injection. The hypothetical phase voltage vector and residual for fault reasoning can be obtained by inputting the suspected OC faults positions to the model. The hierarchical fault diagnosis scheme involves two steps. First, the group-level fault can be located according to voltage residual vector amplitude and angle. Considering the impact of parameter error, dead time, and delay time, an adaptive residual vector amplitude threshold is designed. Next, the device-level fault can be located by building two suspected phase voltage models to approximate the real system. Furthermore, the fault location rules under zero-crossing (ZC) and non-ZC conditions are summarized. Especially, the proposed hypothesis method has correctness verification ability to avoid misdiagnosis. Experimental results show the robustness and effectiveness of the proposed low coupling fault diagnosis method.

19 December 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WZWeiwei Zhang
Weiwei Zhang
YHYigang He
Yigang He
JCJianfei Chen
Jianfei Chen
This article proposes a new phase voltage vector residual-based fault diagnosis method to distinguish the similar open-circuit (OC) fault features of different switches in the three-level T-type inverter. The fault feature based on phase voltage residual can be generated with the designed expected phase voltage model considering different modulation strategies and modes. Under the zero-crossing (ZC) and non-ZC conditions of the faulty phase, the voltage vector residual characteristics caused by OC faults can be summarized. An adaptive residual vector amplitude threshold is designed based on uncertainty propagation using parameter error, dead time, and delay time as system error inputs. In addition, a hierarchical fault diagnosis scheme is proposed, which involves two steps. First, the group-level fault can be located according to voltage residual vector amplitude and angle. Next, the three-level modulation mode of all phase legs is switched to the two-level mode to further identify the faulty switch from the faulty group. The proposed method can achieve a reasonable balance between robustness and rapidity. Meanwhile, complexity and adaptability are also considered. Experimental results under various conditions sufficiently verify the robustness and effectiveness of the proposed fault diagnosis method.

29 March 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WZWeiwei Zhang
Weiwei Zhang
YHYigang He
Yigang He
Xiao WangXiao Wang
Xiao Wang
JCJianfei Chen
Jianfei Chen
Capacitors and semiconductor power devices are the most fragile components in power electronic systems. Hence, designing a comprehensive method for online switch fault diagnosis (FD) and capacitor condition monitoring (CM) is conducive to guaranteeing the reliability of the three-level T-type (3L-T) inverter in an all-around way. First, based on modeling the 3L-T inverter on the dc link and ac side, the inherent harmonic components of the dc link under normal and open-circuit fault conditions are analyzed. Furthermore, the capacitor current reconstruction method is designed. Subsequently, a comprehensive FD and CM framework is proposed, which consists of signal injection, extra hardware, 3L-T model, FD, and CM submodules. In FD, the detection variable, which is the function of output current and its changing rate, is designed, and the fault location is carried out based on the phase current residual and the sum of the neutral-point voltage residual. The capacitance estimation method is introduced based on the input current reconstruction technology and recursive least squares algorithm using the inherent or injected ac component on the dc link. Finally, experimental results demonstrate that the proposed comprehensive method merits high estimation accuracy, fast dynamic response, and better FD performance under various conditions.

14 July 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
WZWeiwei Zhang
Weiwei Zhang
YHYigang He
Yigang He
CWChuankun Wang
Chuankun Wang
MCMingyun Chen
Mingyun Chen
CSChunsong Sui
Chunsong Sui
This article presents a fault diagnosis method in the two-level three-phase voltage source converter (VSC) systems based on the average-phase voltage (APV) model without additional sensors or hardware circuits, which can diagnose and locate multiple open-circuit (OC) faults correctly and quickly. First, based on the idea of APV within one switching period and the changing rules of basic voltage vector after OC faults, the APV model consisting of grid-side APV (GAPV) model, prefault converter-side APV (CAPV) model, and postfault CAPV model is proposed. The APV model can be used to estimate the phase voltage under different OC faults. And then, the residual feature between GAPV and CAPV is analyzed under different single or multiple OC faults. With the help of the proposed APV model, both single and multiple OC faults can be diagnosed by deviation polarity, which avoids the complex deviation polarity sequences judgment. Meanwhile, the fault diagnosis method has the ability of correctness verification, which can strengthen the robustness and prevent false alarms. Finally, the effectiveness of the proposed model and method is validated with experiments; the multiple OC faults can be located within 2.5 ms.

30 December 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WZWeiwei Zhang
Weiwei Zhang
YHYigang He
Yigang He
JCJianfei Chen
Jianfei Chen
BDBolun Du
Bolun Du
Traditional fault diagnosis (FD) and condition monitoring (CM) methods for three-level T-type (3L-T) inverters are studied separately, which is not conducive to guaranteeing the reliability of the 3L-T inverter in an all-around way. This article presents a unified open-circuit FD and CM method for the 3L-T inverter based on the proposed on -state voltage measurement circuit (OVMC). The designed OVMC comprises a voltage limiter, an absolute value circuit, and a minimum value circuit, separating all the OVs and actual switching state information with a few devices and terminals. The corresponding sampling method is designed under the space vector pulsewidth modulation mode, and the sampling frequency is only twice the switching frequency. Three exceptional cases are considered during the implementation to achieve accurate OV sampling. The proposed method for fault locating requires only a straightforward lookup table without complicated feature extraction and threshold setting steps. Meanwhile, the FD results would help to correct the OV distribution. Experimental results demonstrate that the proposed unified FD and CM method merits high measurement accuracy, fast response speed, and short FD time.