The open-switch fault of voltage source converters (VSC) may change the switching state and distort the current, which is the basis for model-based fault diagnosis methods. Based on the analysis of the switching state, this letter presents a post-fault current model to estimate the current of each phase after one open-switch fault occurs. Combined with the current model-based method, the proposed post-fault model can be used not only to check the accuracy of the diagnosis result but also to detect multiple open-switch faults. The current, voltage and driving signals used in this model are all from the VSC control system, therefore, this model can be easily implemented without additional sensors or hardware. Finally, the effectiveness of the proposed model is verified by the experimental results.
14 July 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This article presents a fault diagnosis method in the two-level three-phase voltage source converter (VSC) systems based on the average-phase voltage (APV) model without additional sensors or hardware circuits, which can diagnose and locate multiple open-circuit (OC) faults correctly and quickly. First, based on the idea of APV within one switching period and the changing rules of basic voltage vector after OC faults, the APV model consisting of grid-side APV (GAPV) model, prefault converter-side APV (CAPV) model, and postfault CAPV model is proposed. The APV model can be used to estimate the phase voltage under different OC faults. And then, the residual feature between GAPV and CAPV is analyzed under different single or multiple OC faults. With the help of the proposed APV model, both single and multiple OC faults can be diagnosed by deviation polarity, which avoids the complex deviation polarity sequences judgment. Meanwhile, the fault diagnosis method has the ability of correctness verification, which can strengthen the robustness and prevent false alarms. Finally, the effectiveness of the proposed model and method is validated with experiments; the multiple OC faults can be located within 2.5 ms.
Prognostics and health management (PHM) for electronic devices is intricate yet crucial in an era of electricity. The impending future of electric vehicles and clean energy requires more in-depth scrutiny and monitoring of their storage elements, lithium-ion batteries. State-of-health (SOH), as one of the most evident indicators for battery degradation quantifications, is a matter of vital importance that worths more attention. In this regard, this paper proposes a novel SOH prognostics framework for lithium-ion batteries considering the limitations in the recorded measurements through the use of linear statistical knearest neighbors (LSKNN) data interpolation, maximal information entropy search (MIES), and collective sparse variational Gaussian process regression (CSVGPR). First, the incomplete charging measurements are processed by LSKNN to infer the missing data points and suppress the unanticipated noises in the extracted temporal features, which indicate the trend of degradation. Then, the MIES scheme is proposed to filter the features that are extraneous to the SOHs of the corresponding batteries and that greatly correlate to the other features in the feature set. Finally, the CSVGPR model, considering the uncertainties within each of the sparse variational Gaussian processes, is utilized to implement SOH prognosis. The proposed framework is verified by a subset of the repository from NASA. In the test, multiple prognostics comparisons of innerbattery tests, cross-battery tests, and tests with other statistical learning methods are presented. The experiment results lend support to the superiority and effectiveness of the work.
This paper presents an open‐switch fault detection, and identification method for a neutral‐point clamped rectifier system. A new calculation method for phase‐to‐phase pole voltage deviations is proposed for reducing calculation errors. In this way, the more accurate diagnosis can be achieved. Both single‐switch faults, and multiple‐switch faults can be identified effectively by using fewer diagnostic variables, which makes the diagnostic method simpler, and more reliable. And all the variables can be simply calculated by signals which are available to the control system of the rectifier, avoiding the use of additional hardware. Moreover, different voltage thresholds are designed for different faulty feature sections to further reduce the diagnostic time. Additionally, a diagnostic result checking method is proposed to avoid the misdiagnosis when considering the effect of outer‐switch faults. Finally, experiments are carried out, and the results show the robustness, and effectiveness of the proposed method.