Chunmei Guo

Dr. Chunmei Guo


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
RGRong Gao
Rong Gao
WSWeijin Sun
Weijin Sun
YHYuxin Hao
Yuxin Hao
HLhe zhong lu
he zhong lu
CGChunmei Guo
Chunmei Guo
CMChong Meng
Chong Meng
The energy consumption of data centers has become increasingly prominent. To address the conflict between the characteristic of inhibiting heat dissipation for traditional insulated building envelopes and the cooling demands of data center rooms all year, this study proposes a novel composite envelope structure for data center rooms that integrates passive radiative cooling with air-layer insulation (PRC-AL). The results demonstrate that under internal heat source power densities of 300–1000 W/m2 without additional cooling measures, the PRC-AL composite envelope structure reduces indoor air temperatures by 16.16–30.81% compared to the traditional insulation structure (TIS). Meanwhile, the application of the PRC-AL composite envelope structure leads to significant reductions in annual cumulative cooling load per unit area: 1617.69 kWh/m2 in Harbin, 1359.49 kWh/m2 in Tianjin, 1135.25 kWh/m2 in Shanghai, 994.97 kWh/m2 in Guiyang, and 918.70 kWh/m2 in Guangzhou. These findings indicate that the proposed PRC-AL composite envelope structure not only effectively lowers indoor air temperatures but also reduces cooling loads in data center rooms, providing an efficient pathway for energy conservation in data centers. This research offers a theoretical foundation for optimizing the design of building envelopes in data centers and contributes to sustainable development in the digital infrastructure sector.

30 March 2021 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
YRYanlin Ren
Yanlin Ren
CGChunmei Guo
Chunmei Guo
JLJian Lv
Jian Lv
JXJixiang Xu
Jixiang Xu
SDSihang Dong
Sihang Dong
SGShiwei Guo
Shiwei Guo
The film wetted area is a significant factor affecting the heat and mass transfer of liquid desiccant. In this article, a mathematical model with wetness coefficient of cross-flow energy recovered indirect evaporative cooling (ERIEC)-assisted liquid desiccant dehumidifier (LDD) based on a finite-element method was developed to predict the effect of wetness coefficient on the plate heat exchanger (PHE) effectiveness and dehumidification efficiency, taking into account the thermal resistance and incomplete wetting of liquid film. In addition, an experimental system of a cross-flow ERIEC-assisted LDD was established to validate the model; the validation of the model demonstrated good agreement with the experimental data to within 10%. With this model, increasing the wetness coefficient from 0.1 to 1, the PHE effectiveness gradually increased from 3.7% to 39.1% and the dehumidification efficiency increased gradually from 3.5% to 35.2%. This meant that the nonwetting or partial wetting of liquid film hindered the dehumidification performance. Therefore, a novel TiO2 super-hydrophilic coating was applied to raise the wetness coefficient and improve the dehumidification performance. Within the experimental range, spraying a super-hydrophilic coating (1% nanosized TiO2 solution) in the primary channel of the dehumidifier could increase the PHE effectiveness and dehumidification efficiency by 2.5–5% and 5–30%, respectively.

1 February 2009 in Transactions of Tianjin University
Verified
Journal Article
Closed access
PDF file
CGChunmei Guo
Chunmei Guo
YZYufeng Zhang
Yufeng Zhang
RCRu Chang
Ru Chang
XWXiaodong Wang
Xiaodong Wang