Rong Gao

Dr. Rong Gao

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
RGRong Gao
Rong Gao
WSWeijin Sun
Weijin Sun
YHYuxin Hao
Yuxin Hao
HLhe zhong lu
he zhong lu
CGChunmei Guo
Chunmei Guo
CMChong Meng
Chong Meng
The energy consumption of data centers has become increasingly prominent. To address the conflict between the characteristic of inhibiting heat dissipation for traditional insulated building envelopes and the cooling demands of data center rooms all year, this study proposes a novel composite envelope structure for data center rooms that integrates passive radiative cooling with air-layer insulation (PRC-AL). The results demonstrate that under internal heat source power densities of 300–1000 W/m2 without additional cooling measures, the PRC-AL composite envelope structure reduces indoor air temperatures by 16.16–30.81% compared to the traditional insulation structure (TIS). Meanwhile, the application of the PRC-AL composite envelope structure leads to significant reductions in annual cumulative cooling load per unit area: 1617.69 kWh/m2 in Harbin, 1359.49 kWh/m2 in Tianjin, 1135.25 kWh/m2 in Shanghai, 994.97 kWh/m2 in Guiyang, and 918.70 kWh/m2 in Guangzhou. These findings indicate that the proposed PRC-AL composite envelope structure not only effectively lowers indoor air temperatures but also reduces cooling loads in data center rooms, providing an efficient pathway for energy conservation in data centers. This research offers a theoretical foundation for optimizing the design of building envelopes in data centers and contributes to sustainable development in the digital infrastructure sector.

1 September 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
CGChunmei Guo
Chunmei Guo
RBRuxue Bai
Ruxue Bai
RGRong Gao
Rong Gao
YLYu Li
Yu Li
HXHang Xiong
Hang Xiong
LWLeilei Wang
Leilei Wang
Compared to conventional condensation dehumidification systems, a solar liquid desiccant air conditioning system (SLDAC) offers distinct advantages, enabling independent control of temperature and humidity while operating at low carbon levels. This paper proposes a low-carbon SLDAC thermal mass exchange model that uses an indirect evaporative cooling liquid dehumidifier and photovoltaic thermal and air source heat pump for combined driving of the solution regeneration process. The system simulation model was created using MATLAB and TRNSYS software. An experimental comparison was conducted between the dehumidification module and the regeneration module, and the system's performance was simulated with an airflow of 150 m3/h in the Tianjin area. The results indicate an average dehumidification efficiency of 44.03% and a regeneration efficiency of 40.80% throughout the cooling season. During the cooling season, the power generation of the system met the power demand and produced a surplus of 85.36 kWh, achieving overall self-sufficiency in power consumption. The optimized system's operating parameters were proposed, with regeneration temperatures of 57 °C in June and September and 65 °C in July and August. During the cooling season, the system's regeneration capacity exceeded its dehumidification capacity for 84.90% of the operating time. As a result of optimization, the system's carbon emissions were reduced by 59.35%.

11 May 2026 in Environmental Research
Verified
Journal Article
Closed access
LZLingling Zhong
Lingling Zhong
RZRuiyang Zhao
Ruiyang Zhao
ZLZening Li
Zening Li
RGRong Gao
Rong Gao
XZXinbo Zhang
Xinbo Zhang

1 January 2025 in Energy Engineering
Verified
Journal Article
Open access
PDF file
YLYifan Li
Yifan Li
CZCongzhe Zhu
Congzhe Zhu
RGRong Gao
Rong Gao
BYBin Yang
Bin Yang
The local overheating issue is a serious threat to the safe operation of data centers (DCs). The chip-level liquid cooling with pool boiling is expected to solve this problem. The effect of nano configuration and surface wettability on the boiling characteristics of copper surfaces is studied using molecular dynamics (MD) simulation. The argon is chosen as the coolant, and the wall temperature is 300 K. The main findings and innovations are as follows. (1) Compared to the smooth surface and fin surface, the cylindrical nano cavity obtains the superior boiling performance with earlier onset of nucleate boiling (ONB), larger heat flux because of the higher heat transport rate. (2) The nano cavity with hydrophilicity can improve the response speed and heat dissipation efficiency. Compared to the contact angle θ = 121°, the formation times of nucleate bubble and film boiling for the θ = 0° are reduced by 90.84% and 93.57%, respectively. (3) A deeper cavity of 3.3 nm is beneficial for triggering boiling and improving the heat dissipation rate. The highest heat flux can be achieved at 21.86 × 108 W/m2, which can meet the cooling requirements of the micro devices with ultra-high heat flux (107–108 W/m2). The coupling effect of nano configuration and surface wettability is illustrated, and the essential reasons for the enhanced heat transport are revealed. The findings can guide the optimization of cooling systems and promote the practical application of phase change liquid cooling in DCs.

28 August 2026 in Fire Technology
Verified
Journal Article
Closed access
PDF file
MLMinzhang Liu
Minzhang Liu
NGNi Gao
Ni Gao
KLKaisen Liang
Kaisen Liang
SLShu Liu
Shu Liu
RGRong Gao
Rong Gao
BYBin Yang
Bin Yang

1 October 2025 in Physics of Fluids
Verified
Journal Article
Closed access
RGRong Gao
Rong Gao
YZYuan Zhao
Yuan Zhao
CGChunmei Guo
Chunmei Guo
YHYuxin Huo
Yuxin Huo
YYYuwen You
Yuwen You
BYBin Yang
Bin Yang
In traditional data center cooling systems, fouling deposition on the inner surfaces of enhanced tubes severely affects heat exchange efficiency and operational safety, leading to significant economic losses. Due to the lack of long-term fouling test data, most of the existing fouling prediction models are constant fouling factors or semi-empirical formulas established based on accelerated particulate fouling data. These models have low computational accuracy, poor generalizability, and certain limitations in engineering application constraints. To address these challenges, this study develops and validates a high-precision prediction model for combined fouling growth based on data augmentation using long-term fouling test data. First, to overcome the challenge of insufficient data, a physics-informed Wasserstein generative adversarial network with gradient penalty model is constructed in this study. The fouling thermal resistance database is expanded based on the generative adversarial network (GAN), utilizing the generated data as training sets. Simultaneously, the physical information is combined with the traditional GAN to establish a joint loss function containing physical constraints and improve the quality of the generated data. Second, a physics-informed-convolutional neural network-long short-term memory (LSTM)-Transformer model is introduced in this paper to improve prediction accuracy. To comprehensively extract the global feature information and the nonlinear relationship between each feature and the fouling thermal resistance, the Transformer is integrated with LSTM, creating a feature fusion fouling growth prediction model. Finally, SHapley Additive exPlanations were employed for interpretability analysis of the prediction model, with validation conducted using the long-term fouling test data from ASHRAE RP-1677. The results demonstrate that, compared to the baseline without data augmentation under various operating conditions, the average goodness-of-fit (R2) of the prediction model increased from −0.193 to 0.783, while the average prediction final bias decreased from 23.87% to 2.8%, confirming the superior performance of the proposed methodology.