Vera Faustino

Dr. Vera Faustino

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
VFVera Faustino
Vera Faustino
Susana O. CatarinoSusana O. Catarino
Susana O. Catarino
Rui A. LimaRui A. Lima
Rui A. Lima
Graca MinasGraca Minas
Graca Minas

27 March 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
DBDavid Bento
David Bento
RRRaquel Rodrigues
Raquel Rodrigues
VFVera Faustino
Vera Faustino
Diana PinhoDiana Pinho
Diana Pinho
CFCarla Sofia Veiga Fernandes
Carla Sofia Veiga Fernandes
Rui A. LimaRui A. Lima
Rui A. Lima
Techniques, such as micropipette aspiration and optical tweezers, are widely used to measure cell mechanical properties, but are generally labor-intensive and time-consuming, typically involving a difficult process of manipulation. In the past two decades, a large number of microfluidic devices have been developed due to the advantages they offer over other techniques, including transparency for direct optical access, lower cost, reduced space and labor, precise control, and easy manipulation of a small volume of blood samples. This review presents recent advances in the development of microfluidic devices to evaluate the mechanical response of individual red blood cells (RBCs) and microbubbles flowing in constriction microchannels. Visualizations and measurements of the deformation of RBCs flowing through hyperbolic, smooth, and sudden-contraction microchannels were evaluated and compared. In particular, we show the potential of using hyperbolic-shaped microchannels to precisely control and assess small changes in RBC deformability in both physiological and pathological situations. Moreover, deformations of air microbubbles and droplets flowing through a microfluidic constriction were also compared with RBCs deformability.

25 September 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
VFVera Faustino
Vera Faustino
RRRaquel Rodrigues
Raquel Rodrigues
Diana PinhoDiana Pinho
Diana Pinho
Elisio CostaElisio Costa
Elisio Costa
Alice Santos-SilvaAlice Santos-Silva
Alice Santos-Silva
Rui A. LimaRui A. Lima
Rui A. Lima
The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.

19 October 2015 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
RRRaquel Rodrigues
Raquel Rodrigues
Diana PinhoDiana Pinho
Diana Pinho
VFVera Faustino
Vera Faustino
Rui A. LimaRui A. Lima
Rui A. Lima

22 July 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Reinaldo SouzaReinaldo Souza
Reinaldo Souza
VFVera Faustino
Vera Faustino
IGInês Maia Gonçalves
Inês Maia Gonçalves
Ana MoitaAna Moita
Ana Moita
MBManuel Bañobre-López
Manuel Bañobre-López
Rui A. LimaRui A. Lima
Rui A. Lima
Fluids containing colloidal suspensions of nanometer-sized particles (nanofluids) have been extensively investigated in recent decades with promising results. Driven by the increase in the thermal conductivity of these new thermofluids, this topic has been growing in order to improve the thermal capacity of a series of applications in the thermal area. However, when it comes to measure nanofluids (NFs) thermal conductivity, experimental results need to be carefully analyzed. Hence, in this review work, the main traditional and new techniques used to measure thermal conductivity of the NFs are presented and analyzed. Moreover, the fundamental parameters that affect the measurements of the NFs’ thermal conductivity, such as, temperature, concentration, preparation of NFs, characteristics and thermophysical properties of nanoparticles, are also discussed. In this review, the experimental methods are compared with the theoretical methods and, also, a comparison between experimental methods are made. Finally, it is expected that this review will provide a guidance to researchers interested in implementing and developing the most appropriate experimental protocol, with the aim of increasing the level of reliability of the equipment used to measure the NFs thermal conductivity.

30 December 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
EPElmano Pinto
Elmano Pinto
VFVera Faustino
Vera Faustino
RRRaquel Rodrigues
Raquel Rodrigues
Diana PinhoDiana Pinho
Diana Pinho
VGValdemar Garcia
Valdemar Garcia
Rui A. LimaRui A. Lima
Rui A. Lima
Microfluidic devices are electrical/mechanical systems that offer the ability to work with minimal sample volumes, short reactions times, and have the possibility to perform massive parallel operations. An important application of microfluidics is blood rheology in microdevices, which has played a key role in recent developments of lab-on-chip devices for blood sampling and analysis. The most popular and traditional method to fabricate these types of devices is the polydimethylsiloxane (PDMS) soft lithography technique, which requires molds, usually produced by photolithography. Although the research results are extremely encouraging, the high costs and time involved in the production of molds by photolithography is currently slowing down the development cycle of these types of devices. Here we present a simple, rapid, and low-cost nonlithographic technique to create microfluidic systems for biomedical applications. The results demonstrate the ability of the proposed method to perform cell free layer (CFL) measurements and the formation of microbubbles in continuous blood flow.