Rafał Kurdyła

Mr. Rafał Kurdyła

Department of Electric Power Engineering, Rzeszów University of Technology, Rzeszów, Podkarpackie, Poland
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KEKristián Eliáš
Kristián Eliáš
ĽBĽubomír Beňa
Ľubomír Beňa
Rafał KurdyłaRafał Kurdyła
Rafał Kurdyła
With the increasing penetration of photovoltaic systems in low-voltage distribution networks, new operational challenges arise for distribution system operators. This article focuses on a comprehensive analysis of the impact of single-phase and three-phase photovoltaic systems on voltage magnitude, voltage unbalance, and currents flowing through distribution lines. The steady-state operation was calculated using EA-PSM simulation software, and the assessment of the impact of photovoltaic systems on the network was carried out using the international standard EN 50160. Simulation results show that a high penetration of photovoltaic systems causes significant changes in the network’s voltage profile. The study also includes a proposal of measures aimed at mitigating the adverse effects of decentralized generation in photovoltaic systems on the distribution network. Among the most effective measures is the selection of an appropriate conductor cross-section for distribution lines. The results also indicate that, in terms of negative impact on the network, it is preferable to prioritize three-phase connection over single-phase connection, because for the same impact on the network, three-phase photovoltaic systems can inject several times more power into the network compared to single-phase systems. These and other findings may be beneficial, especially for distribution system operators in planning the operation and development of networks.

1 September 2022 in Scientific Journals of Rzeszów University of Technology Series Electrotechnics
Verified
Journal Article
Open access
PDF file
Rafał KurdyłaRafał Kurdyła
Rafał Kurdyła
W artykule przedstawiono wyniki pomiarów związane z wpływem instalacji fotowoltaicznych na pracę sieci dystrybucyjnej nN. Na wstępie artykuł omawia zagadnienia związane ze skokami oraz zapadami napięć generowanymi przez rozpoczęcie procedury oddawania wyprodukowanej przez instalacje fotowoltaiczne energii elektrycznej do sieci. W punktach tych ukazano rzędy wartości skoków oraz napięćw sieci dystrybucyjnej. Kolejno przedstawione zostały wskaźniki PST (z ang. wskaźnik krótkiego migotania światła) oraz PLT (z ang. wskaźnik długiego migotania światła), które negatywnie wpływają na komfort odbiorcy. W kolejnej części zaprezentowane zostało RVC (z ang. szybkie zmiany napięcia) wielofazowe, czyli szybkie zmiany wartości napięcia zasilania. W punkcie tym przestawiono częstotliwość występowania oraz wartości napięć przy gwałtownych jego zmianach. W ostatniej części poruszono kwestię przerw wielofazowych, przy tym przedstawiono i omówiono, jak niekorzystnie wpływają one na urządzenia użytku domowego. W celu zbierania danych z analizatorów wykorzystany został zainstalowany na obiekcie analizator sieci SONEL PQM-702, który pozwolił na zebranie dużej liczby wartości pomiarowych. Dzięki zebranym danym, możliwe było określenie wielu wartości napięć oraz prądów, zachowania sieci w czasie rzeczywistym, a także ilość zdarzeń, jakie wystąpiły zarówno po stronie odbiorcy jak i sieci dystrybucyjnej. Pozwoliło to na ukazanie realnego oddziaływania instalacji fotowoltaicznych na sieć dystrybucyjną. Analiza ta pozwoliła również na określenie częstotliwości występowania anomalii przy produkcji energii elektrycznej przez instalację fotowoltaiczną i jednoczesnym pobieraniu energii elektrycznej z sieci. Dzięki uzyskanym wynikom pomiarów możliwe było określenie wpływu mikroinstalacji na sieć. Artykuł kończy się zebraniem wniosków z przeprowadzonej analizy oraz podsumowaniem. The article presents the results of measurements related to the impact of photovoltaic installations on the operation of the LV distribution network. At the beginning, the article discusses the issues related to spikes and dips in voltage generated by the beginning of the procedure of feeding electricity produced by photovoltaic installations into the network. It presents the orders of values of spikes and voltages in the distribution network. Next, the PST and PLT indicators that negatively affect the comfort of the consumer are presented. In the next section, multiphase RVC, that is, rapid changes in supply voltage values, is presented. In this section, the frequency of occurrence and the values of voltages at rapid changes of the voltage are presented. The last section deals with the issue of multiphase interruptions. In doing so, it is presented and discussed how they adversely affect household appliances. In order to collect data from the analyzers, the SONEL PQM-702 network analyzer installed on the object was used, which allowed to collect a large number of measurement values. Thanks to the collected data, it was possible to determine many values of voltages and currents, real-time behavior of the network, as well as the number of events that occurred both on the consumer side and on the distribution network. This allowed to show the real impact of photovoltaic installations on the distribution network. This analysis also allowed us to determine the frequency of anomalies in the production of electricity by the photovoltaic installation and the simultaneous extraction of electricity from the grid. With the measurement results obtained, it was possible to determine the impact of the micro-installation on the grid. The paper ends with a collection of conclusions from the analysis and a summary.

23 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KEKristián Eliáš
Kristián Eliáš
ĽBĽubomír Beňa
Ľubomír Beňa
Rafał KurdyłaRafał Kurdyła
Rafał Kurdyła
Paweł PijarskiPaweł Pijarski
Paweł Pijarski
Dominik PrzepiórkaDominik Przepiórka
Dominik Przepiórka
Decentralized energy sources are currently an integral part of low-voltage distribution networks. In line with the energy policy of the European Union, it can be expected that their penetration in these networks will continue to grow. But are distribution networks prepared for such a future? This study addresses this question using data measured over 30 days in a real low-voltage distribution network where PV systems are installed at 18% of the consumption points. In cooperation with a Polish distribution system operator, all consumption points were equipped with smart meters, which allowed the voltage magnitude, voltage unbalance, and transferred power to be evaluated at 51 measurement points simultaneously. Data analysis shows that decentralized sources significantly affect power flows and the overall active power balance, which is directly reflected in the network’s voltage profile. A surplus of active power was recorded on 29 of the 30 days and raised the voltage above the upper limit defined by the EN 50160 standard on 27 of them. The hosting capacity of the analyzed network is therefore already exceeded at the current penetration, and the network is not ready to integrate further decentralized sources in line with European Union energy targets.