A four stage helicoaxial pump was tested under varying operating conditions. A range of inlet pressures, rotational speeds (3000, 3600 rpm), and gas void fractures (GVFs) were considered for two fluid viscosities. The head developed and power input to run the pump were recorded. Head, power input and efficiency decrease as the GVF increases with best efficiency point (BEP) moving towards lower flow rate conditions. Dimensional analysis was conducted to evaluate the applicability of current affinity laws to the two-phase flow performance of the pump under consideration. Dimensionless head coefficient and power coefficients were defined for two-phase flow, considering the homogeneity in the two-phase fluid properties. Deviations in the two-phase affinity coefficients from the common law curve increases with GVF. To bridge this gap, a new correlation is proposed with a revised flow coefficient that allows all the head coefficient data to collapse on a single line with a greater degree of accuracy.
Subsea production fluid is quite often characterized by the presence of frac sand, which causes wear within the pump, and alters the performance envelop. One of the design parameters critically affecting reliability is the thrust load generated by an impeller. The change in thrust load due to the erosion of the pump stages is not completely understood, and no relationship exists to foresee these reactive forces due to the complexity involved in predicting the flow characteristics. The purpose of this study is to understand the change in axial thrust due to commonly encountered wear mechanisms across the pump section especially wear across stage clearance seals. Based on in-house erosion testing of a mixed flow pump, three mesh models were built with each representing the pump condition at three different time intervals, namely, 0 h, 52 h, and 117 h of the total test time. The pump numerical models were validated using performance data collected from experimental testing. Axial thrust was found to increase with an increase in wear rate across stage seals. Since the increased clearance causes head degradation as well as an increase in thrust, the relationship of this head degradation is correlated with a change in thrust to further expand the affinity laws.
1 November 2019 in Journal of Petroleum Science and Engineering