Seongok Chae

Mr. Seongok Chae

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2025 in Wearable Technologies
Verified
Journal Article
Open access
PDF file
SPSung-Jin Park
Sung-Jin Park
SCSeongok Chae
Seongok Chae
HPHyung-Soon Park
Hyung-Soon Park
Passive wearable devices are widely used for fitness and have also become fashionable. There is increasing interest in adding functionality, such as knee stability, to these compact devices, which are more convenient for daily wear than separate devices like braces or exoskeletons. This study designed and assessed flexion taping passive wearable devices (FTPW). The design emphasized providing adequate flexion moment capacity and controlling varus/valgus movement to prevent knee injuries. In this research, 20 healthy women performed single leg drop (SLD) and step-up (SU) tests with and without muscle fatigue. Knee joint angle, muscle activation, metabolic cost, and blood flow were measured across FTPW, passive wearable devices without flexion taping (PW), and control shorts (Ctrl). In the SLD test after muscle fatigue, FTPW produced a significantly larger knee flexion angle during landing. In the SU test, before and after fatigue, knee varus angle was notably higher with FTPW. Additionally, FTPW showed reduced knee flexor fatigue, indicated by smaller median frequency shifts, and improved blood flow compared to PW. No significant differences in respiratory exchange ratio were detected among the three conditions. Overall, FTPW demonstrated strong potential to enhance knee kinematics, muscle activation, and blood flow, pointing to benefits for both performance improvement and injury prevention. By delivering focused support in a compact format, FTPW may serve as an innovative passive wearable solution that supports daily movement, comfort, and daily activities. This emphasizes the device’s promise as an alternative to bulkier knee aids, merging style and functionality effectively.

5 November 2025 in Biomechanics
Verified
Journal Article
Open access
PDF file
SCSeongok Chae
Seongok Chae
HKHyun Soo Kang
Hyun Soo Kang
HLHojik Lee
Hojik Lee
YJYoo-Jin Jun
Yoo-Jin Jun
SCSeung Myung Choi
Seung Myung Choi
HPHyung-Soon Park
Hyung-Soon Park
Plantar fasciitis (PFS) is a leading cause of heel pain, yet its clinical course varies widely. Although plantar fascia thickness (PFT) is often used as a pain marker, its prognostic value remains unclear. Objective: This study investigates whether foot arch morphology underlies distinct biomechanical profiles in PFS patients, potentially explaining the variability in its presentation. Methods: The cross-sectional study included 30 patients with PFS and 10 healthy controls. PFS patients were classified by arch type (pes rectus, pes planus, pes cavus) using the Arch Height Index (AHI). Baseline comparisons between healthy controls and PFS subgroups assessed PFT, Foot Function Index (FFI), joint stiffness ratio, and gait parameters. Results: PFT differed across groups but was not significantly associated with FFI scores (p = 0.233). The pes cavus group exhibited a lower metatarsophalangeal (MTP) stiffness ratio compared with healthy (p < 0.05). Pes planus and pes rectus groups showed excessive pronation, and the pes cavus group showed limited ankle dorsiflexion, indicating distinct gait mechanisms (p < 0.05). Conclusions: Foot arch morphology influences gait biomechanics, stiffness, and PFT in individuals with PFS. Incorporating individual arch types into clinical decision-making may facilitate more personalized interventions and improve treatment outcomes.

15 July 2025 in Wearable Technologies
Verified
Journal Article
Open access
PDF file
SCSeongyun Cho
Seongyun Cho
BJByungjun Jeon
Byungjun Jeon
MKMinki Kim
Minki Kim
SCSeongok Chae
Seongok Chae
SYSeungmin Ye
Seungmin Ye
HPHyung-Soon Park
Hyung-Soon Park
Recent advancements in wearable robots have focused on developing soft, compliant, and lightweight structures to provide comfort for the users and to achieve the primary function of assisting body motions. The interaction forces induced by physical human-robot interaction (pHRI) not only cause skin discomfort or pain due to relatively high localized pressures but also degrade the wearability and the safety of the wearer’s joints by unnaturally altering the joint reaction forces (JRFs) and the joint reaction moments (JRMs). Although the correlation between excessive JRFs/JRMs and joint-related conditions has been reported by researchers, the biomechanical effects of forces and moments caused by the pHRI of a wearable robot on the wearer’s joints remain under-analyzed. In this study, we propose a method of measuring and analyzing these interactions and effects, using a custom-designed soft, three-degree-of-freedom (DOF) force sensor. The sensor is made of four Hall effect sensors and a neodymium magnet embedded in a silicone elastomer structure, enabling simultaneous measurement of normal and two-axis shear forces by detecting the distance changes between the magnet and each Hall effect sensor. These sensors are embedded in contact pads of a commercial wearable robot and measure the interaction forces, used for calculating JRF and JRM. We also propose a modified inverse dynamics approach that allows us to consider the physical interactions between the robot and the human body. The proposed method of sensing and analysis provides the potential to enhance the design of future wearable robots, ensuring long-term safety.

18 September 2025 in Wearable Technologies
Verified
Journal Article
Open access
PDF file
SPSung-Jin Park
Sung-Jin Park
SCSeongok Chae
Seongok Chae
HPHyung-Soon Park
Hyung-Soon Park