Yoo-Jin Jun

Dr. Yoo-Jin Jun

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2025 in Biomechanics
Verified
Journal Article
Open access
PDF file
SCSeongok Chae
Seongok Chae
HKHyun Soo Kang
Hyun Soo Kang
HLHojik Lee
Hojik Lee
YJYoo-Jin Jun
Yoo-Jin Jun
SCSeung Myung Choi
Seung Myung Choi
HPHyung-Soon Park
Hyung-Soon Park
Plantar fasciitis (PFS) is a leading cause of heel pain, yet its clinical course varies widely. Although plantar fascia thickness (PFT) is often used as a pain marker, its prognostic value remains unclear. Objective: This study investigates whether foot arch morphology underlies distinct biomechanical profiles in PFS patients, potentially explaining the variability in its presentation. Methods: The cross-sectional study included 30 patients with PFS and 10 healthy controls. PFS patients were classified by arch type (pes rectus, pes planus, pes cavus) using the Arch Height Index (AHI). Baseline comparisons between healthy controls and PFS subgroups assessed PFT, Foot Function Index (FFI), joint stiffness ratio, and gait parameters. Results: PFT differed across groups but was not significantly associated with FFI scores (p = 0.233). The pes cavus group exhibited a lower metatarsophalangeal (MTP) stiffness ratio compared with healthy (p < 0.05). Pes planus and pes rectus groups showed excessive pronation, and the pes cavus group showed limited ankle dorsiflexion, indicating distinct gait mechanisms (p < 0.05). Conclusions: Foot arch morphology influences gait biomechanics, stiffness, and PFT in individuals with PFS. Incorporating individual arch types into clinical decision-making may facilitate more personalized interventions and improve treatment outcomes.

15 July 2025 in Wearable Technologies
Verified
Journal Article
Open access
PDF file
SCSeongyun Cho
Seongyun Cho
BJByungjun Jeon
Byungjun Jeon
MKMinki Kim
Minki Kim
SCSeongok Chae
Seongok Chae
SYSeungmin Ye
Seungmin Ye
HPHyung-Soon Park
Hyung-Soon Park
Recent advancements in wearable robots have focused on developing soft, compliant, and lightweight structures to provide comfort for the users and to achieve the primary function of assisting body motions. The interaction forces induced by physical human-robot interaction (pHRI) not only cause skin discomfort or pain due to relatively high localized pressures but also degrade the wearability and the safety of the wearer’s joints by unnaturally altering the joint reaction forces (JRFs) and the joint reaction moments (JRMs). Although the correlation between excessive JRFs/JRMs and joint-related conditions has been reported by researchers, the biomechanical effects of forces and moments caused by the pHRI of a wearable robot on the wearer’s joints remain under-analyzed. In this study, we propose a method of measuring and analyzing these interactions and effects, using a custom-designed soft, three-degree-of-freedom (DOF) force sensor. The sensor is made of four Hall effect sensors and a neodymium magnet embedded in a silicone elastomer structure, enabling simultaneous measurement of normal and two-axis shear forces by detecting the distance changes between the magnet and each Hall effect sensor. These sensors are embedded in contact pads of a commercial wearable robot and measure the interaction forces, used for calculating JRF and JRM. We also propose a modified inverse dynamics approach that allows us to consider the physical interactions between the robot and the human body. The proposed method of sensing and analysis provides the potential to enhance the design of future wearable robots, ensuring long-term safety.

2 April 2026 in JMIR Preprints
Verified
Preprint
Open access
KLKun-Do Lee
Kun-Do Lee
YJYoo-Jin Jun
Yoo-Jin Jun
HPHyung-Soon Park
Hyung-Soon Park
BACKGROUND Accurate joint motion analysis in the sagittal, frontal, and transverse planes is critical for clinical assessments. While retroreflective-marker-based systems (e.g., VICON) have been the gold standard in motion analysis due to their high precision, their high cost and the requirement for expert setup limit their use outside laboratory environments. Markerless methods have emerged but often suffer from reduced accuracy, especially for non-sagittal joint motions in the limbs. OBJECTIVE This study proposes a single-camera-based motion capture system that utilizes printed visual patterns on compression tights paired with a low-cost RGBD camera to estimate three-dimensional joint angle trajectories during human dynamic motions. The primary objective is achieving clinically acceptable accuracy using a single camera to enable accurate joint kinematic analysis. METHODS The proposed system was demonstrated with a focus on the knee joint. For three-degree-of-freedom knee joint angle estimation, unstructured visual patterns were printed on the thigh and shank regions of lower-limb compression tights. The visual patterns were designed using specific initials but can be replaced with commercial logos or other graphic designs. The proposed algorithm independently tracks pose changes of the visual pattern regions on the thigh and shank to estimate knee joint kinematics. The algorithm consists of a pattern segmentation network (PSN) for extracting thigh and shank pattern images and an optical flow network (PON) optimized to track inter-frame pattern motion with sub-pixel accuracy. Using dense pixel-wise correspondences estimated by the PON, point clouds are reconstructed from depth images and registered across consecutive frames to estimate segment-wise pose changes, enabling continuous knee joint angle tracking. RESULTS Ten healthy participants were recruited for the experiment. Each participant wore compression tights printed with visual patterns and performed five repetitions of a single-leg squat. Knee joint angles were simultaneously measured using the proposed system and a VICON motion capture system, and the differences between the two measurements were analyzed. Experimental validation against the VICON as a reference system achieved root-mean-square errors of 2.2°, 1.4°, and 1.2° for flexion/extension, abduction/adduction, and rotation, respectively. CONCLUSIONS The proposed system achieved clinically acceptable accuracy and provides a practical solution for three-degree-of-freedom knee joint kinematics assessment without requiring extensive equipment or multi-camera setups. CLINICALTRIAL The experimental protocols were approved by the Institutional Review Board at the Korea Advanced Institute of Science and Technology (ICTRP Identifier KCT0011010, URL: https://trialsearch.who.int/Trial2.aspx?TrialID=KCT0011010)

23 September 2026 in Advanced Healthcare Materials
Verified
Journal Article
Open access
BCBohyung Choi
Bohyung Choi
YJYoo-Jin Jun
Yoo-Jin Jun
HCHeewon Choee
Heewon Choee
KLKun‐Do Lee
Kun‐Do Lee
HKHeesoo Kim
Heesoo Kim
HPHyung-Soon Park
Hyung-Soon Park
Effective musculoskeletal rehabilitation requires simultaneous assessment of muscle activation and movement kinematics, yet no current system enables this at home. Laboratory motion capture systems provide accurate kinematics but require controlled environments, while portable inertial sensors enable home use at the cost of drift and incomplete joint angle resolution. Critically, neither approach provides direct physiological insight into the muscle activation driving functional movement. Here, we present NeuroVisio SyncPatch, a wearable multimodal platform that unifies conformal surface electromyography (EMG) with vision‐based motion tracking within a single sports–tape interface. The device integrates stretchable, breathable, electrically conductive adhesive (ECA) electrodes that enable stable EMG acquisition, along with printed optical markers supporting accurate 3‐degree‐of‐freedom (DOF) knee angle estimation utilizing a single RGB‐D camera per leg via a convolutional neural network (CNN)‐based vision pipeline. By integrating high‐fidelity EMG signals (SNR > 13 dB) with joint kinematics, the system delivered real‐time kinematic feedback during movement together with EMG‐derived neuromuscular feedback after each trial. Multimodal feedback training showed improved knee alignment and intermuscular coordination in participants with dynamic knee valgus (DKV), demonstrating closed‐loop modulation of maladaptive motor patterns. NeuroVisio SyncPatch establishes a scalable, mechanically robust, and physiologically comprehensive framework for home‐deployable musculoskeletal rehabilitation.