Fiber reinforced polymer (FRP) composites are gaining acceptance in concrete structural applications due to their high ratio of strength/stiffness to self-weight and corrosion resistance. This study focused on the structural behavior and the performance of concrete columns internally reinforced with glass fiber reinforced plastic (GFRP) rebars. Twelve series of concrete columns with varied longitudinal reinforcement, cross section, concrete cover, and type of lateral reinforcement were tested under compression loading. The results show that the amount of GFRP longitudinal and lateral reinforcement slightly affects the column strength. The lateral reinforcement affects the confining pressure and inelastic deformation, and its contribution to the confined compressive strength increases with the GFRP reinforcement ratio. In addition, the confining pressure increases both concrete strength and deformability in the inelastic range. The confinement effectiveness coefficient varied from 3.0 to 7.0 with longitudinal reinforcement. The average deformability factors were 4.2 and 2.8 with spirals and ties, respectively. Lateral reinforcement had a more pronounced effect on deformability than on column strength.
25 July 2017 in International Journal of Civil Engineering
For many decades, both the lateral-torsional and local buckling strengths of fiber-reinforced polymer (FRP) structural members have been studied extensively by numerous researchers and designers. Many complex prediction models and equations of the buckling strength have been proposed. Typically, most design communities prefer simpler design procedures and equations. Simplified, albeit approximate, buckling-strength equations of pultruded FRP structural beams have been proposed with acceptable accuracy. Herein, the proposed buckling-strength results were compared with those based on prestandard equations and available experimental data. The proposed simplified prestandard lateral-torsional buckling equation provided higher strength results than the experimental data based on the upper-bound experimental results by approximately 11%. Also, the proposed simplified lateral-torsional buckling-strength equation was reasonably acceptable for the design purpose (within 18% difference) compared to the predicted strength provided by the prestandard equations. For local buckling strength, the maximum percentage difference in local flange buckling strength was found to be less than 15%, whereas the proposed web local buckling-strength equations provided excellent agreement with the predicted strength (i.e., less than 5% difference for all cross sections). The proposed design equations are very useful in enabling improved design calculations of FRP structural members.
11 October 2015 in International Journal of Polymer Science
Because of high strength and stiffness to low self-weight ratio and ease of field installation, fiber reinforced polymer (FRP) composite materials are gaining popularity as the materials of choice to replace deteriorated concrete bridge decks. FRP bridge deck systems with lower damping compared to conventional bridge decks can lead to higher amplitudes of vibration causing dynamically active bridge deck leading serviceability problems. The FRP bridge models with different bridge configurations and loading patterns were simulated using finite element method. The dynamic response results under varying FRP deck system parameters were discussed and compared with standard specifications of bridge deck designs under dynamic loads. In addition, the dynamic load allowance equation as a function of natural frequency, span length, and vehicle speed was proposed in this study. The proposed dynamic load allowance related to the first flexural frequency was presented herein. The upper and lower bounds’ limits were established to provide design guidance in selecting suitable dynamic load allowance for FRP bridge systems.
10 December 2013 in The Baltic Journal of Road and Bridge Engineering
In recent years, researchers have investigated the load distribution factors due to vehicle wheel loads. Several load distribution factors for fiber reinforced polymer deck-steel stringer bridge systems have been proposed. Unfortunately, these load distribution factors are only used for each particular fiber reinforced polymer bridge deck system. Therefore, the objective of the research effort is to present the load distribution results of a parametric study using finite element analysis. The simplified load distribution factors were developed herein. The bridge parameters for this study were stringer spacing, bridge span, width of bridge models, types of fiber reinforced polymer bridge decks and numbers of traffic lanes. The bridge responses under various wheel loading conditions were investigated. The simplified distribution factors based on