Bing Liang

Dr. Bing Liang


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BLBing Liang
Bing Liang
WLWei Liu
Wei Liu
KLKun Liu
Kun Liu
MZMengde Zhou
Mengde Zhou
Yang ZhangYang Zhang
Yang Zhang
ZJZhenyuan Jia
Zhenyuan Jia
Full-field displacement perception and digital twins for core components play a crucial role in the precision manufacturing industry, such as aviation manufacturing. This paper presents a real-time full-field displacement perception method for the combination of online multipoint displacement monitoring and matrix completion theory. Firstly, a conceptual full-field displacement perception model based on the observed information of the multi-points is established. To obtain the full-field displacements of a core component, the component is divided into plentiful discrete points, including observed and unobserved points, based on which the relationship between the observed points and the full-field displacements is established. Then, the solution method of the full-field displacement perception model is proposed. Based on the matrix completion principle and the big data of the simulation, the optimization problem is employed to work out the model and, meanwhile, the pseudo-code is put forward. Finally, the full-field displacement perception experiments are performed. Repeated experiments show that the max error of the displacements calculated by the proposed method can be less than 0.094 mm and the median error can be less than 0.054 mm, while the average time frame can be less than 0.48 s, which is promising considering the high precision and efficiency requirements of the assembly of large aircraft.

16 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MZMengde Zhou
Mengde Zhou
WLWei Liu
Wei Liu
LTLinlin Tang
Linlin Tang
ZYZhuang Yao
Zhuang Yao
ZWZhengquan Wen
Zhengquan Wen
ZJZhenyuan Jia
Zhenyuan Jia
In wind tunnel tests, the low-frequency and large-amplitude vibration of the cantilever sting result in poor test data in pitch plane and yaw plane, more seriously, even threatens the safety of wind tunnel tests. To ensure the test data quality, a multidimensional vibration suppression method is proposed to withstand the vibration from any direction, which is based on a system with stackable piezoelectric actuators and velocity feedback employing accelerometers. Firstly, the motion equation of the cantilever sting system is obtained by Hamilton’s principle with the assumed mode method. Then, the multidimensional active control mechanism is qualitatively analyzed and a negative velocity feedback control algorithm combined with a root mean square (RMS) evaluation method is introduced to realize active mass and active damping effect, meanwhile, a weight modification method is performed to determine the sequence number of the stacked piezoelectric actuators and the weight of control voltages in real time. Finally, a multidimensional vibration suppression system was established and verification experiments were carried out in lab and a transonic wind tunnel. The results of lab experiments indicate that the damping ratio of the system is improved more than 4.3 times and the spectrum analyses show reductions of more than 23 dB. In addition, wind tunnel test results have shown that for the working conditions (α = −4~10° with γ = 0° or α = −4~10° with γ = 45°) respectively at 0.6 Ma and 0.7 Ma, the remainder vibration is less than 1.53 g, which proves that the multidimensional vibration suppression method has the ability to resist vibration from any direction to ensure the smooth process of wind tunnel tests.

28 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
WLWei Liu
Wei Liu
BLBing Liang
Bing Liang
ZJZhenyuan Jia
Zhenyuan Jia
DFDi Feng
Di Feng
XJXintong Jiang
Xintong Jiang
MZMengde Zhou
Mengde Zhou
High precision position control is essential in the process of parts manufacturing and assembling, where eddy current displacement sensors (ECDSs) are widely used owing to the advantages of non-contact sensing, compact volume, and resistance to harsh conditions. To solve the nonlinear characteristics of the sensors, a high-accuracy calibration method based on linearity adjustment is proposed for ECDSs in this paper, which markedly improves the calibration accuracy and then the measurement accuracy. After matching the displacement value and the output voltage of the sensors, firstly, the sensitivity is adjusted according to the specified output range. Then, the weighted support vector adjustment models with the optimal weight of the zero-scale, mid-scale and full-scale are established respectively to cyclically adjust the linearity of the output characteristic curve. Finally, the final linearity adjustment model is obtained, and both the calibration accuracy and precision are verified by the established calibration system. Experimental results show that the linearity of the output characteristic curve of ECDS adjusted by the calibration method reaches over 99.9%, increasing by 1.9–5.0% more than the one of the original. In addition, the measurement accuracy improves from 11–25 μ m to 1–10 μ m in the range of 6mm, which provides a reliable guarantee for high accuracy displacement measurement.

1 December 2006
Verified
Journal Article
Closed access
BLBing Liang
Bing Liang
LZLijun Zhu
Lijun Zhu
ZLZhihui Liang
Zhihui Liang
XWXiufang Weng
Xiufang Weng
XLXiaoling Lu
Xiaoling Lu
XWXiongwen Wu
Xiongwen Wu

20 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MZMengde Zhou
Mengde Zhou
WLWei Liu
Wei Liu
QWQinqin Wang
Qinqin Wang
BLBing Liang
Bing Liang
LTLinlin Tang
Linlin Tang
XCXiaochun Cui
Xiaochun Cui
Active vibration control is the most effective method for stochastic multidimensional vibration in wind tunnel tests, in which vibration monitoring is the core foundation. Vibrations are induced by the disturbances of several complex air flow instabilities under extreme test conditions with high attack angles. Here, a decoupled unified observation method is proposed in order to fully monitor stochastic multidimensional vibration. First, stochastic multidimensional vibration is explained using the Cartesian coordinate system. Then, the multidimensional vibration decoupling of the pitch plane and the yaw plane is realized according to the proposed decoupling design principle of the long cantilever sting. A unified observation method is presented, based on inertial force theory, to observe multidimensional vibration due to acceleration in each decoupling plane. Verification experiments were conducted in lab and a transonic wind tunnel, using an established real-time monitoring system. The results of lab experiments indicate that, in the frequency region of 0–120 Hz, three vibration modes of a selected stochastic vibration can be decoupled and observed through the vibration components in pitch plane and yaw plane. In addition, wind tunnel tests were carried out according to the working conditions (α = −4~10° with γ = 45°) at Ma = 0.6 and Ma = 0.7, respectively. The results show that six vibration modes of two selected stochastic vibrations can be decoupled and observed through the vibration components in pitch plane and yaw plane. The experimental results prove that stochastic vibration can be fully monitored in multiple dimensions through the vibration components in pitch plane and yaw plane using the proposed decoupled unified observation method. Therefore, these results lay the foundation for active vibration control.

1 August 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
LZLi Bing Zhao
Li Bing Zhao
AMAo Shu Meng
Ao Shu Meng
JZJin Rui Zhang
Jin Rui Zhang
BLBing Liang
Bing Liang
ZWZhong Quan Wang
Zhong Quan Wang
HYHao Yu
Hao Yu
Aimed at the characteristic that highcontent of hematite of valuable minerals in overflow of concentrate Before the strong magnetism from Sijiaying Concentrator, by that flocculation test of pure minerals of hematite, quartz, chlorite and investigate that flocculation effect of lime, PAC, PAFC of inorganic flocculants and PAM of organic flocculants to three kinds of pure minerals in this article. The test results show that the bigger sedimentation velocity difference hematite between quartz, chlorite when do not add any flocculants. When adding inorganic flocculants include lime, PAC, PAFC, flocculation effect is better to hematite and quartz, but flocculation effect is bad chlorite; Flocculation effect is better to three pure minerals when adding PAM of organic flocculants.