Austin Castelo

Mr. Austin Castelo

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2024
Verified
Book Chapter
Closed access
PDF file
McKell WoodlandMcKell Woodland
McKell Woodland
ACAustin Castelo
Austin Castelo
MTMais Al Taie
Mais Al Taie
JSJessica Albuquerque Marques Silva
Jessica Albuquerque Marques Silva
MEMohamed Eltaher
Mohamed Eltaher
Kristy K BrockKristy K Brock
Kristy K Brock

30 October 2024 in Cancers
Verified
Journal Article
Open access
PDF file
MAMUHAMMAD AWAIS
MUHAMMAD AWAIS
MTMais Al Taie
Mais Al Taie
COCaleb S. O’connor
Caleb S. O’connor
ACAustin Castelo
Austin Castelo
BABelkacem Acidi
Belkacem Acidi
Kristy K BrockKristy K Brock
Kristy K Brock
Background/Objectives: In the field of surgical medicine, the planning and execution of liver resection procedures present formidable challenges, primarily attributable to the intricate and highly individualized nature of liver vascular anatomy. In the current surgical milieu, intraoperative ultrasonography (IOUS) has become indispensable; however, traditional 2D ultrasound imaging’s interpretability is hindered by noise and speckle artifacts. Accurate identification of critical structures for preservation during hepatectomy requires advanced surgical skills. Methods: An AI-based model that can help detect and recognize vessels including the inferior vena cava (IVC); the right (RHV), middle (MHV), and left (LVH) hepatic veins; the portal vein (PV) and its major first and second order branches the left portal vein (LPV), right portal vein (RPV), and right anterior (RAPV) and posterior (RPPV) portal veins, for real-time IOUS navigation can be of immense value in liver surgery. This research aims to advance the capabilities of IOUS-guided interventions by applying an innovative AI-based approach named the “2D-weigthed U-Net model” for the segmentation of multiple blood vessels in real-time IOUS video frames. Results: Our proposed deep learning (DL) model achieved a mean Dice score of 0.92 for IVC, 0.90 for RHV, 0.89 for MHV, 0.86 for LHV, 0.95 for PV, 0.93 for LPV, 0.84 for RPV, 0.85 for RAPV, and 0.96 for RPPV. Conclusion: In the future, this research will be extended for real-time multi-label segmentation of extended vasculature in the liver, followed by the translation of our model into the surgical suite.

23 October 2024 in Machine Learning for Biomedical Imaging
Verified
Journal Article
Open access
PDF file
McKell WoodlandMcKell Woodland
McKell Woodland
NPNihil Patel
Nihil Patel
ACAustin Castelo
Austin Castelo
MTMais Al Taie
Mais Al Taie
MEMohamed Eltaher
Mohamed Eltaher
Kristy K BrockKristy K Brock
Kristy K Brock
Clinically deployed deep learning-based segmentation models are known to fail on data outside of their training distributions. While clinicians review the segmentations, these models tend to perform well in most instances, which could exacerbate automation bias. Therefore, detecting out-of-distribution images at inference is critical to warn the clinicians that the model likely failed. This work applied the Mahalanobis distance (MD) post hoc to the bottleneck features of four Swin UNETR and nnU-net models that segmented the liver on T1-weighted magnetic resonance imaging and computed tomography. By reducing the dimensions of the bottleneck features with either principal component analysis or uniform manifold approximation and projection, images the models failed on were detected with high performance and minimal computational load. In addition, this work explored a non-parametric alternative to the MD, a k-th nearest neighbors distance (KNN). KNN drastically improved scalability and performance over MD when both were applied to raw and average-pooled bottleneck features. Our code is available at https://github.com/mckellwoodland/dimen_reduce_mahal
1

14 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
McKell WoodlandMcKell Woodland
McKell Woodland
MAMais Altaie
Mais Altaie
COCaleb S. O’connor
Caleb S. O’connor
ACAustin Castelo
Austin Castelo
OLOlubunmi Lebimoyo
Olubunmi Lebimoyo
Kristy K BrockKristy K Brock
Kristy K Brock
This work aims to leverage generative modeling-based anomaly detection to enhance interpretability in AI failure detection systems and to aid data curation for large repositories. For failure detection interpretability, this retrospective study utilized 3339 CT scans (525 patients), divided patient-wise into training, baseline test, and anomaly (having failure-causing attributes—e.g., needles, ascites) test datasets. For data curation, 112,120 ChestX-ray14 radiographs were used for training and 2036 radiographs from the Medical Imaging and Data Resource Center for testing, categorized as baseline or anomalous based on attribute alignment with ChestX-ray14. StyleGAN2 networks modeled the training distributions. Test images were reconstructed with backpropagation and scored using mean squared error (MSE) and Wasserstein distance (WD). Scores should be high for anomalous images, as StyleGAN2 cannot model unseen attributes. Area under the receiver operating characteristic curve (AUROC) evaluated anomaly detection, i.e., baseline and anomaly dataset differentiation. The proportion of highest-scoring patches containing needles or ascites assessed anomaly localization. Permutation tests determined statistical significance. StyleGAN2 did not reconstruct anomalous attributes (e.g., needles, ascites), enabling the unsupervised detection of these attributes: mean (±standard deviation) AUROCs were 0.86 (±0.13) for failure detection and 0.82 (±0.11) for data curation. 81% (±13%) of the needles and ascites were localized. WD outperformed MSE on CT (p < 0.001), while MSE outperformed WD on radiography (p < 0.001). Generative models detected anomalous image attributes, demonstrating promise for model failure detection interpretability and large-scale data curation.

18 February 2026 in medRxiv
Verified
Preprint
Open access
PDF file
ACAustin Castelo
Austin Castelo
COCaleb O’COnnor
Caleb O’COnnor
AGAashish C. Gupta
Aashish C. Gupta
BABrian M. Anderson
Brian M. Anderson
MWMcKell Woodland
McKell Woodland
KBKristy K. Brock
Kristy K. Brock
Artificial intelligence (AI) based segmentation has many medical applications but limited curated datasets challenge model training; this study compares the impact of dataset annotation quality and quantity on whole liver AI segmentation performance. We obtained 3,089 abdominal computed tomography scans with whole-liver contours from MD Anderson Cancer Center (MDA) and a MICCAI challenge. A total of 249 scans were withheld for testing of which 30, MICCAI challenge data, were reserved for external validation. The remaining scans were divided into mixed-curation and highly-curated groups, randomly sampled into sub-datasets of various sizes, and used to train 3D nnU-Net segmentation models. Dice similarity coefficients (DSC), surface DSC with 2mm margins (SD 2mm), the 95th percentile of Hausdorff distance (HD95), and 2D axial slice DSC (Slice DSC) were used to evaluate model performance. The highly curated, 244-scan model (DSC=0.971, SD 2mm=0.958, HD95=2.98mm) performed insignificantly different on 3D evaluation metrics to the mixed-curation 2,840-scan model (DSC=0.971 [ p >.999], SD 2mm=0.958 [ p >.999], HD95=2.87mm [p>.999]). The 710-scan mixed-curation (Slice DSC=0.929) significantly outperformed the highly curated, 244-scan model (Slice DSC=0.923 [ p =0.012]) on the 30 external scans. Highly curated datasets yielded equivalent performance to datasets that were a full order of magnitude larger. The benefits of larger, mixed-curation datasets are evidenced in model generalizability metrics and local improvements. In conclusion, tradeoffs between dataset quality and quantity for model training are nuanced and goal dependent.

29 June 2026 in medRxiv
Verified
Preprint
Open access
JBJeddy Bennett
Jeddy Bennett
McKell WoodlandMcKell Woodland
McKell Woodland
ACAustin Castelo
Austin Castelo
MAMais Altaie
Mais Altaie
AAAjith Anthony
Ajith Anthony
Kristy K BrockKristy K Brock
Kristy K Brock
Deep learning models deployed in clinical imaging frequently encounter distribution shifts, yet most out-of-distribution (OOD) detection methods are evaluated only on controlled research datasets. As a result, it is unclear whether existing approaches can reliably identify segmentation failures that arise in real-world clinical practice. We evaluated six OOD detection methods on a deployed liver CT segmentation model (3D nnU-Net) using internal data from 400 patients and external data from 100 patients collected across nearly 70 sites in 7 countries. One method was Pairwise Surface DSC, a surface-based extension of Pairwise DSC, that we introduced. OOD performance was measured using sensitivity, AUROC, and balanced accuracy, with thresholds determined on an independent cohort of 400 patients using the Youden J statistic. Statistical significance was assessed using McNemar tests and stratified bootstraps ( α = 0.05) with Benjamini–Hochberg correction. Pairwise Surface DSC was the top-performing method, with perfect sensitivities (1.00), near-perfect AUROCs (0.97 internal; 1.00 external), and the highest balanced accuracies (0.94 internal; 0.88 external; p < 0.001). These results show that automated failure detection for liver CT segmentation is clinically feasible and that Pairwise Surface DSC is a promising candidate for deployment. Our code is available at https://github.com/mckellwoodland/liver_ct_ood_translation .