Jeddy Bennett

Jeddy Bennett

Auto-generated profile, based on publicly available information

Jeddy Bennett

Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston TX 77030, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2026 in medRxiv
Verified
Preprint
Open access
JBJeddy Bennett
Jeddy Bennett
McKell WoodlandMcKell Woodland
McKell Woodland
ACAustin Castelo
Austin Castelo
MAMais Altaie
Mais Altaie
AAAjith Anthony
Ajith Anthony
Kristy K BrockKristy K Brock
Kristy K Brock
Deep learning models deployed in clinical imaging frequently encounter distribution shifts, yet most out-of-distribution (OOD) detection methods are evaluated only on controlled research datasets. As a result, it is unclear whether existing approaches can reliably identify segmentation failures that arise in real-world clinical practice. We evaluated six OOD detection methods on a deployed liver CT segmentation model (3D nnU-Net) using internal data from 400 patients and external data from 100 patients collected across nearly 70 sites in 7 countries. One method was Pairwise Surface DSC, a surface-based extension of Pairwise DSC, that we introduced. OOD performance was measured using sensitivity, AUROC, and balanced accuracy, with thresholds determined on an independent cohort of 400 patients using the Youden J statistic. Statistical significance was assessed using McNemar tests and stratified bootstraps ( α = 0.05) with Benjamini–Hochberg correction. Pairwise Surface DSC was the top-performing method, with perfect sensitivities (1.00), near-perfect AUROCs (0.97 internal; 1.00 external), and the highest balanced accuracies (0.94 internal; 0.88 external; p < 0.001). These results show that automated failure detection for liver CT segmentation is clinically feasible and that Pairwise Surface DSC is a promising candidate for deployment. Our code is available at https://github.com/mckellwoodland/liver_ct_ood_translation .

21 December 2025 in Medical Physics
Verified
Journal Article
Open access
JCJaehee Chun
Jaehee Chun
ACAustin Castelo
Austin Castelo
McKell WoodlandMcKell Woodland
McKell Woodland
COCaleb O'COnnor
Caleb O'COnnor
MTMais Al Taie
Mais Al Taie
Kristy K BrockKristy K Brock
Kristy K Brock
Background: Accurate and consistent image segmentation across longitudinal scans is essential in many clinical applications, including surveillance, treatment monitoring, and adaptive interventions. While personalized model adaptation using patient‐specific prior scans has shown promise, current approaches typically rely on fixed training durations and lack mechanisms to determine optimal stopping points on a per‐patient basis, particularly in the absence of validation labels. Purpose: We propose an uncertainty‐guided test‐time optimization (TTO) framework that dynamically adjusts the personalization duration for each patient using a validation‐free stopping criterion based on predictive uncertainty. Methods: Our framework personalizes a generalized segmentation model using patient‐specific prior imaging and selects the optimal checkpoint based on the minimum voxel‐wise predictive uncertainty, estimated via Monte Carlo Dropout (TTO‐MCD) or Deep Ensembling (TTO‐DE). We evaluated the approach on three datasets: 214 pancreas (CT) scans, 243 liver (CT) scans, and 175 head‐and‐neck tumor (MRI) scans, each containing a subset of patients with paired longitudinal scans to enable patient‐specific personalization. Each patient's follow‐up scan was held out for testing. As a baseline, we implemented a fixed‐epoch personalization strategy (Pre‐TTO) using a fivefold cross‐test design to emulate deployable model selection without test label leakage. Results: TTO methods consistently outperformed the Pre‐TTO and unpersonalized baseline across standard metrics, including the Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance (HD95), Mean Surface Distance (MSD), and the proposed LogPenalty Score (LPS), which provides a bounded, interpretable scale that jointly reflects volumetric and boundary fidelity. Paired t ‐tests confirmed statistically significant improvements for pancreas and liver datasets ( p < 0.05), while favorable trends were observed in the head‐and‐neck dataset despite greater anatomical variability. Both TTO‐MCD and TTO‐DE achieved near‐optimal performance without requiring access to labels at test time. Conclusion: Uncertainty‐guided TTO provides a robust, validation‐free strategy for optimizing patient‐specific segmentation models in longitudinal medical imaging. By tailoring personalization based on predictive uncertainty, our method improves segmentation quality across a range of imaging modalities and anatomical targets. This framework supports broad clinical deployment of personalized AI and motivates future extensions to contextual integration and multi‐label segmentation. Code is publicly available at https://github.com/jchun‐ai/uncertainty‐tto .

24 August 2026 in medRxiv
Verified
Preprint
Open access
PDF file
MNMarshall Nielsen
Marshall Nielsen
ACAustin Castelo
Austin Castelo
MAMais Altaie
Mais Altaie
JBJeddy Bennett
Jeddy Bennett
AAAjith Anthony
Ajith Anthony
McKell WoodlandMcKell Woodland
McKell Woodland
Reliable clinical deployment of automated liver segmentation requires mechanisms for detecting failures in rare and previously unseen scenarios. Achieving this goal requires an appropriately calibrated threshold that converts an out-of-distribution (OOD) score into a failure prediction. However, threshold calibration typically relies on expert-labeled failures, creating a substantial annotation burden when failures are rare. Building upon our prior work, which uses Pairwise Surface DSC scores as indicators of segmentation quality, we propose a label-free framework for calibrating OOD score thresholds. First, we fitted a log- t distribution to Pairwise Surface DSC scores from a validation set of 400 internal scans to approximate an in-distribution score distribution. New segmentations were assigned significance scores based on their extremity under this fitted distribution and categorized into Low, Medium, and High Risk review groups using statistically principled cutoffs of 0.25 and 0.05. The fitted log- t distribution provided a strong fit to the observed scores and remained robust to moderate contamination by OOD cases. On an independent test set of 500 internal and external scans, the combined Medium and High Risk categories achieved 100% sensitivity and 79% specificity, whereas the High Risk category alone achieved 78% sensitivity and 96% specificity. These results indicate that clinically meaningful failure detection can be derived from unlabeled data. Our code is available at https://github.com/marshalln7/Label_Free_OOD_Threshold_Selection .

25 September 2026
Verified
Book Chapter
Closed access
PDF file
JBJeddy Bennett
Jeddy Bennett
McKell WoodlandMcKell Woodland
McKell Woodland
ACAustin Castelo
Austin Castelo
MAMais Altaie
Mais Altaie
AAAjith Anthony
Ajith Anthony
Kristy K BrockKristy K Brock
Kristy K Brock