Marc Doumit

Dr. Marc Doumit

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2016 in Journal of Medical Engineering
Verified
Journal Article
Open access
PDF file
AVAnthony Vo
Anthony Vo
MDMarc Doumit
Marc Doumit
GRGloria Rockwell
Gloria Rockwell
Purpose. Injecting triamcinolone acetonide (TA) into a keloid is physically challenging due to the density of keloids. The purpose was to investigate the effects of various syringe and needle combinations on the injection force to determine the most ergonomic combination. Materials and Methods. A load cell was used to generate and measure the injection force. Phase 1: the injection force of 5 common syringes was measured by injecting water into air. The syringe that required the lowest injection force was evaluated with various needle gauges (25, 27, and 30 G) and lengths (16, 25, and 38 mm) by injecting TA (40 mg/mL) into air. The needle-syringe combination with the lowest injection force (CLIF) was deemed the most ergonomic combination. Phase 2: comparisons between the CLIF and a standard combination (SC) were performed by injecting TA into air and tap water into a keloid specimen. Intraclass Correlation Coefficient (ICC) and independent t-test were used. Results. Increasing the syringe caliber, injection speed, and needle gauge and length significantly increased the injection force (p value < 0.001). The SC required a maximum force of 40.0 N to inject water into keloid, compared to 25.0 N for the CLIF. Injecting TA into keloid using the SC would require an injection force that was 103.5% of the maximum force female thumbs could exert compared to 64.8% for the CLIF. ICC values were greater than 0.4. Conclusions. The 1 mL polycarbonate syringe with a 25 G, 16 mm needle (CLIF) was the most ergonomic combination. The SC required a substantial injection force, which may represent a physical challenge for female thumbs.

9 July 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
BFBrandon N. Fournier
Brandon N. Fournier
Edward LemaireEdward Lemaire
Edward Lemaire
ASAndrew J. J. Smith
Andrew J. J. Smith
MDMarc Doumit
Marc Doumit
Lower extremity powered exoskeletons (LEPEs) allow people with spinal cord injury (SCI) to stand and walk. However, the majority of LEPEs walk slowly and users can become fatigued from overuse of forearm crutches, suggesting LEPE design can be enhanced. Virtual prototyping is a cost-effective way of improving design; therefore, this research developed and validated two models that simulate walking with the Bionik Laboratories’ ARKE exoskeleton attached to a human musculoskeletal model. The first model was driven by kinematic data from 30 able-bodied participants walking at realistic slow walking speeds (0.2-0.8 m/s) and accurately predicted ground reaction forces (GRF) for all speeds. The second model added upper limb crutches and was driven by 3D-marker data from five SCI participants walking with ARKE. Vertical GRF had the strongest correlations (>0.90) and RMSE and mediolateral COP trajectory had the weakest (<0.35), for both models. Strong correlations and small RMSE between predicted and measured GRFs support use of these models for optimizing LEPE joint mechanics and improving LEPE design.

1 October 2019 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
ZLZlatko Lovrenovic
Zlatko Lovrenovic
MDMarc Doumit
Marc Doumit

1 July 2019 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
SPScott Pardoel
Scott Pardoel
MDMarc Doumit
Marc Doumit

1 July 2017 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
MDMarc Doumit
Marc Doumit
SPScott Pardoel
Scott Pardoel

24 February 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
BCBethany Cseke
Bethany Cseke
TUThomas K. Uchida
Thomas K. Uchida
MDMarc Doumit
Marc Doumit
Objective: Development of walking assist exoskeletons is a growing area of study, offering a solution to restore, maintain, and enhance mobility. However, applying this technology to the elderly is challenging and there is currently no consensus as to the optimal strategy for assisting elderly gait. The gait patterns of elderly individuals often differ from those of the younger population, primarily in the ankle and hip joints. This study used musculoskeletal simulations to predict how ankle and hip actuators might affect the energy expended by elderly participants during gait. Methods: OpenSim was used to generate simulations of 10 elderly participants walking at self-selected slow, comfortable, and fast speeds. Ideal flexion/extension assistive actuators were added bilaterally to the ankle or hip joints of the models to predict the maximum metabolic power that could be saved by exoskeletons that apply torques at these joints. Results: Compared to the unassisted scenario, the use of ideal hip actuators resulted in 21±5%, 26±5%, and 30±6% reductions in average metabolic power consumption at slow, comfortable, and fast walking speeds, respectively; use of ideal ankle actuators resulted in 12±3%, 14±2%, and 16±1% metabolic savings, respectively. Conclusion: The simulations suggest that providing hip assistance to elderly individuals during walking can result in significantly greater metabolic savings than ankle assistance, assuming kinematics and total joint moments do not change substantially with assistance. Significance: The achieved research results and analysis provide exoskeleton developers guidance on optimally designing walking assist exoskeletons, thus promoting consensus toward the optimal strategy for assisting elderly individuals.