Rationale: The vast majority of children around the world undergoing adenotonsillectomy for obstructive sleep apnea–hypopnea syndrome (OSA) are not objectively diagnosed by nocturnal polysomnography because of access availability and cost issues. Automated analysis of nocturnal oximetry (nSpO2), which is readily and globally available, could potentially provide a reliable and convenient diagnostic approach for pediatric OSA. Methods: Deidentified nSpO2 recordings from a total of 4,191 children originating from 13 pediatric sleep laboratories around the world were prospectively evaluated after developing and validating an automated neural network algorithm using an initial set of single-channel nSpO2 recordings from 589 patients referred for suspected OSA. Measurements and Main Results: The automatically estimated apnea–hypopnea index (AHI) showed high agreement with AHI from conventional polysomnography (intraclass correlation coefficient, 0.785) when tested in 3,602 additional subjects. Further assessment on the widely used AHI cutoff points of 1, 5, and 10 events/h revealed an incremental diagnostic ability (75.2, 81.7, and 90.2% accuracy; 0.788, 0.854, and 0.913 area under the receiver operating characteristic curve, respectively). Conclusions: Neural network–based automated analyses of nSpO2 recordings provide accurate identification of OSA severity among habitually snoring children with a high pretest probability of OSA. Thus, nocturnal oximetry may enable a simple and effective diagnostic alternative to nocturnal polysomnography, leading to more timely interventions and potentially improved outcomes.
There is an unmet clinical need for pharmacologic treatment for metabolic dysfunction-associated steatotic liver disease (MASLD). Hepatocyte cell death is a hallmark of this highly prevalent chronic liver disease, but the dominant type of cell death remains uncertain. Here we report that ferroptosis, an iron-catalyzed mode of regulated cell death, contributes to MASLD. Unsupervised clustering in a cohort of biopsy-proven MASLD patients revealed a subgroup with hepatic ferroptosis signature and lower glutathione peroxidase 4 (GPX4) levels. Likewise, a subgroup with reduced ferroptosis defenses was discerned in public transcriptomics datasets. Four weeks of choline-deficient L-amino acid-defined high-fat diet (CDAHFD) induced MASLD with ferroptosis in mice. Gpx4 overexpression did not affect steatohepatitis, instead CDAHFD protected from morbidity due to hepatocyte-specific Gpx4 knockout. The ferroptosis inhibitor UAMC-3203 attenuated steatosis and alanine aminotransferase in CDAHFD and a second model, i.e., the high-fat high-fructose diet (HFHFD). The effect of monounsaturated and saturated fatty acids supplementation on ferroptosis susceptibility was assessed in human HepG2 cells. Fat-laden HepG2 showed a drop in ferroptosis defenses, increased phosphatidylglycerol with two polyunsaturated fatty acid (PUFA) lipid tails, and sustained ferroptosis sensitivity. In conclusion, this study identified hepatic ferroptosis as a detrimental factor in MASLD patients. Unexpectedly, non-PUFA supplementation to hepatocytes altered lipid bilayer composition to maintain ferroptosis sensitivity. Based on findings in in vivo models, ferroptosis inhibition represents a promising therapeutic target in MASLD.
For more than three decades, type III devices have been used in the diagnosis of sleep disordered breathing in supervised as well as unsupervised settings. They have satisfactory positive and negative predictive values for detecting obstructive and central sleep apnoea in populations with moderately high pre-test probability of symptoms associated with these events. However, standardisation of commercially available type III devices has never been undertaken and the technical specifications can vary widely. None have been subjected to the same rigorous processes as most other diagnostic modalities in the medical field. Although type III devices do not include acquisition of electroencephalographic signals overnight, the minimum number of physical sensors required to allow for respiratory event scoring using standards outlined by the American Academy of Sleep Medicine remains debatable. This technical standard summarises data on type III studies published since 2007 from multiple perspectives in both adult and paediatric sleep practice. Most importantly, it aims to provide a framework for considering current type III device limitations in the diagnosis of sleep disordered breathing while raising research- and practice-related questions aimed at improving our use of these devices in the present and future.
There is an increasing need for suitable tools to evaluate body composition in paediatrics. The Body Composition Monitor (BCM) shows promise as a method, but reference values in children are lacking. Twenty children were included and measured twice by 4 different raters to asses inter- and intra-rater reproducibility of the BCM. Reliability was assessed using the Bland-Altman method and by calculating intraclass correlation coefficients (ICCs). The intra-rater ICCs were high (≥ 0.97) for all parameters measured by BCM as were the inter-rater ICCs for all parameters (≥ 0.98) except for overhydration (0.76). Consequently, a study was set up in which BCM measurements were performed in 2058 healthy children aged 3–18.5 years. The age- and gender-specific percentile values and reference curves for body composition (BMI, waist circumference, fat mass and lean tissue mass) and fluid status (extracellular and intracellular water and total body water) relative to age were produced using the GAMLSS method for growth curves.Conclusion:A high reproducibility of BCM measurements was found for fat mass, lean tissue mass, extracellular water and total body water. Reference values for these BCM parameters were calculated in over 2000 children and adolescents aged 3 to 18 years. What is Known• The 4-compartment model is regarded as the ‘gold standard’ of body composition methods, but is inappropriate for regular follow-up or screening of large groups, because of associated limitations.• Body Composition Monitor® is an inexpensive field method that has the potential to be an adequate monitoring tool.What is New• Good reproducibility of BCM measurements in children provides evidence to use the device in longitudinal follow-up, multicentre and comparative studies.• Paediatric reference values relative to age and sex for the various compartments of the body are provided.